• Title/Summary/Keyword: solar cycles

Search Result 111, Processing Time 0.025 seconds

A Study on the Regional Energy Conservation Effects of a Multi-stage Outdoor Air Enabled Cooling System in a Data Center (데이터센터용 멀티 외기이용 냉방시스템의 지역별 에너지 절감효과에 대한 연구)

  • Park, Moon-Ki;Chang, Hyun-Jae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.71-80
    • /
    • 2017
  • A Data center houses a large number of server computers, storage and etc in racks. With the rapid increase of heat generation rates per rack in a data center, energy consumption rates for cooling have been increased year by year. In this study, energy conservation effects of a MOA (multi-stage outdoor air enabled) cooling system in a data center has been investigated when it is applied to 5 different locations, Korea. As results, Energy conservation effects of the MOA cooling system was achieved at about 20% to 30%. Humidifier operation time was 40 to 55 days when supply air temperature was maintained at 13, and humidity condition was kept within the allowed range even though humidifier was off. Furthermore, humidification was not needed when supply air temperature was maintained at $25^{\circ}C$. In selected 5 locations in Korea, the difference of regional climatic conditions affected no more than 5% in cooling energy consumption rates.

Preliminary Simulation Study on 1 MWe STP System in China (중국 1 MWe급 태양열발전시스템에 대한 기초 운전해석)

  • Yao, Zhihao;Wang, Zhifeng;Kang, Yong-Heack;Kim, Jong-Kyu;Wei, Xiudong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.698-701
    • /
    • 2007
  • DAHAN, the first 1 MWe Solar Power Tower system locates north to Beijing where nearby The Great Wall is now under construction with cooperation between China and Korea. Results in predicting the preliminary performance of this central receiver system are presented in this paper. Operating cycles under some typical weather condition days are simulated and commented. These results can be used to assess the impact of alternative plant designs or operating strategies on annual energy production, with the final objective being to optimize the design of central receiver power plants. Two subsystems are considered in the system simulation: the solar field and the power block. Mathematic models are used to represent physical phenomena and relationships so that the characteristics of physical processes involving these phenomena can be predicted. Decisions regarding the best position for locating heliostats relative to the receiver and how high to place the receiver above the field constitute a multifaceted problem. Four different kinds of field layout are designed and analyzed by the use of ray tracing and mathematical simulation techniques to determine the overall optical performance ${\eta}_{field}$ and the spillage ${\eta}_{spill}$.The power block including a Rankine cycle is analyzed by conventional energy balance methods.

  • PDF

Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source (저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Han, Chul-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.

A Study of Ocean Thermal Energy Conversion Systems Using Kalina cycle and Regenerative Rankine cycle (Kalina 사이클과 재생 Rankine 사이클을 이용한 해양 온도차 발진 시스템)

  • Shin, S.H.;Jung, D.S.;Kim, C.B.;Seo, T.B.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.101-113
    • /
    • 1999
  • Thermodynamic performance of a simple Rankine cycle, regenerative Rankine cycle, and Kalina cycle for Ocean thermal Energy Conversion(OTEC) is evaluated under the same condition with various working fluids. The evaporator and condenser are modeled by a UA and LMTD method while the turbine and pump are modeled by considering isentropic efficiencies. As for the working fluids, R22, R134a, R32, propylene, ammonia are used for the Rankine cycles while ammonia/water and R32/R134a mixtures are used for Kalina cycle. Calculated results show that newly developed fluids such non-ozone depleting refrigerants as R134a and R32 perform as well as R22 and ammonia. The regenerative Rankine cycle showed a 1.2 to 2.8% increase in energy efficiency as compared to the simple Rankine cycle while the Kalina cycle with ammonia/water mixture showed a 1.8% increase in energy efficiency. The efficiency of the Kalina cycle with R32/R134a mixtures is the same as that of a simple Rankine cycle using R22. Therefore, the regenerative Rankine cycle turns out to be best choice for OTEC applications.

  • PDF

Review on Data Acquisition of Renewable Power Generators (신재생발전기의 데이터 취득방안에 대한 고찰)

  • Lee, Bong-Kil;Kim, Wan-Hong;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.1-20
    • /
    • 2020
  • In accordance with the Government's policy, renewable power generation is expanding very largely. This leads to increasing uncertainty in the power market and power system owing to the intermittent and fluctuating output characteristics of renewable power generators. Data on the acquisition of renewable power generators can be largely classified according to the operation of the power market and power system. Data on the settlement for the payment for the power amount are acquired in the power market, and real-time data for monitoring the status and output of the generators are acquired in the power system. However, renewable power generators operating in the power market have different acquisition cycles depending on the method of communication of the power meter. They acquire data only for settlement purposes and have no real-time data, which requires improvement. In this paper, the acquisition status is reviewed by classifying the data of renewable power generators into settlement and real-time data. In addition, measures and acquisition criteria for real-time data of renewable power generators for improving the acquisition method are proposed.

Electrochemical Performance of High-Voltage LiMn0.8Fe0.2PO4 Cathode with Polyacrylonitrile (PAN)-Based Gel Polymer Electrolyte

  • Kwon, O. Hyeon;Kim, Jae-Kwang
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.547-552
    • /
    • 2019
  • Electrochemical properties of $LiMn_{0.8}Fe_{0.2}PO_4$ cathode were investigated with gel polymer electrolyte (GPE). To access fast and efficient transport of ions and electrons during the charge/discharge process, a pure and well-crystallized $LiMn_{0.8}Fe_{0.2}PO_4$ cathode material was directly synthesized via spray-pyrolysis method. For high operation voltage, polyacrylonitrile (PAN)-based gel polymer electrolyte was then prepared by electrospinning process. The gel polymer electrolyte showed high ionic conductivity of $2.9{\times}10^{-3}S\;cm^{-1}$ at $25^{\circ}C$ and good electrochemical stability. $Li/GEP/LiMn_{0.8}Fe_{0.2}PO_4$ cell delivered a discharge capacity of $159mAh\;g^{-1}$ at 0.1 C rate that was close to the theoretical value ($170mAh\;g^{-1}$). The cell allows stable cycle performance (99.3% capacity retention) with discharge capacity of $133.5mAh\;g^{-1}$ for over 300 cycles at 1 C rate and exhibits high rate-capability. PAN-based gel polymer is a suitable electrolyte for application in $LiMn_{0.8}Fe_{0.2}PO_4/Li$ batteries with perspective in high energy density and safety.

Study on Solution-Processed Flexible Electrochromic Devices with Improved Coloration Efficiency and Stability

  • Gihwan Song;Haekyoung Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • According to the recent global warming, it is necessary to use energy efficiently together with eco-friendly energy. The development of alternative technologies is requisite for managing the current energy and climate crises. In this regard, "smart windows," which can control solar radiation, can be used to mitigate energy demands. Electrochromic devices (ECDs) effectively control the amount of solar energy reaching commercial and other living areas and maintain climate conditions via color modulation in response to small external stimuli, such as temperature and light irradiation. However, the performance and the stability of ECDs depend on the state of the electrolyte and sealing of the device. To resolve the aforementioned issues, an ECD was manufactured by using a poly (methyl methacrylate) (PMMA)-based gel polymer electrolyte (GPE), and a laminating method was used to adequately seal the ECD. The concentrations of PMMA, acetonitrile (ACN), and ferrocene (Fc) were controlled to optimize the composition of the GPE to achieve an enhanced electrochromic performance. The fabricated GPE-based ECD afforded high optical contrast (~81.92%), with high electrochromic stability up to 10,000 cycles. Moreover, the lamination method employing the GPE could be used to fabricate large-area ECDs.

Rock-Surface Temperatures of Baeknokdam Northwest Face in the Summit Area of Mt. Halla (한라산 백록담 서북벽 암온의 향별 특성)

  • KIM, Taeho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.3
    • /
    • pp.109-121
    • /
    • 2012
  • Rock-surface temperatures were observed at a trachytic lava dome, called as Baeknokdam Northwest Face, in the summit area of Mt. Halla, Jeju Island, to examine the frequency and occurrence season of freeze-thaw cycles and the rate of temperature changes during a freezing period. Long-term measurements were recorded over 18 months from November 2006 to April 2008, at a 1-hour logging interval and rock depth of 1.5 cm. Both diurnal freeze-thaw cycles and effective freeze-thaw cycles appear in larger numbers on a south-facing rock face than a north-facing rock face. The diurnal cycles were dominantly observed on February and March for the south face and on November and April for the north face, respectively. The annual freeze-thaw cycles were confirmed in terms of the presence of seasonal freezing periods lasting from mid-November to mid-April for the south face and from early-November to late-April for the north face, respectively. The rate of decreasing temperatures during the seasonal freezing periods is larger on the north face than the south face. Notwithstanding the lower numbers of freeze-thaw events, the north face experiences a higher frost intensity since the number of hours below $-3^{\circ}C$ is larger on the north face than the south face. The number of freeze-thaw events and the duration of days with continuous sub-zero rock temperatures largely depend on the solar radiation controlled by the aspect of the monitored rock surfaces, and thus the high-frequency short-term frost cycle dominantly appears on the south face and the annual frost cycle on the north face, respectively.

Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture (NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구)

  • Kim, Ji-Young;Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • This research aims todevelopa compression/absorption hybrid heat pump system using an $NH_3/H_2O$ as working fluid.The heatpump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a desorber, a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above $90^{\circ}C$ using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangementof the plate heat exchangers with regard tothe concentration and distribution at the inlet of the absorber.

A Study on The Characteristics of Solar Cell by Thermal Shock test (열충격 시험을 통한 태양전지 특성에 관한 연구)

  • Kang, Min-Soo;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.249-253
    • /
    • 2012
  • In this study, The report analysed the characteristics of power drop in solar cell through thermal shock test. The solar cells were tested 500 cycles in $-40^{\circ}C$ lowest temperature and $120^{\circ}C$ highest temperature by thermal shock test on ironbound conditions, that excerpted standard of PV Module(KS C IEC-61215). The result of the efficiency analysis through measure of I-V, efficiency of Cell decreased from 13.9% to 11.0% and decreasing rate was 20.9% after test. The result of the surface analysis through EL, solar cell has damage of gridfinger and ribbon joint. Cell cracks were founded in damage of cells through cross section of solar cells. Also, Fill factors were decreased from 72.3% to 62.0% after thermal shock test and decreasing rate is 11.8%. therefore, Yearly power drop is aggravated with facts that cell crack, damage of surface and power loss of cell by change of I-V characteristic curve with decreasing of parallel resistance.