• Title/Summary/Keyword: solar collector

Search Result 442, Processing Time 0.023 seconds

Thermal Performance Analysis of Glass Evacuated Solar Collector with a Finned Tube (내관에 휜을 부착한 진공관형 집열기의 열성능 해석)

  • Kim, Yong;Seo, Tae-Beom;Kang, Yong-Hyuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • The thermal performance of glass evacuated tube solar collectors with finned tubes is numerically modelled with code and investigated to see the effect of toe inner tube diameter and incidence angle. The solar collector consists of a two-layered glass tube and an inner tube. Finned tubes are used as the inner tube of the collector in order to improve the performance of the solar collector. Two strip-type fins are attached on the opposite sides of the inner tube surface. The fin is wide enough to be tightly fatted inside the glass tube. The results show that if the incidence angle is small, the effect of the tube diameters is not significant on the thermal performance and the outlet air temperature. If the incidence angle is large, however, the outlet air temperature and the performance increases as the inner tube diameter increases.

Performance Prediction of a Solar Power System with Stirling Engine (Matching Collector/Receiver with Engine/Generator Systems) (스털링엔진 태양열 발전시스템의 성능예측(집열기.수열기 및 엔진.발전기 시스템의 조화))

  • Bae, Myung-Whan;Chang, Hyung-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.794-799
    • /
    • 2001
  • The simulation analyses of a solar power system with monolithic concentrator by using a stirling engine are carried out to predict the system performance in four test sites. The site has different intensities and distributions of direct solar radiation respectively. Seoul, Pusan and Cheju in Korea, and Naha in Japan are selected as test sites. To accomplish the same demand of a 25 kW output that the power level of a system has, it needs to take the matching of collector/receiver with engine/generator systems. In such a case, also, the size of the collector is sometimes adjusted. In this study, the diameter of the collector is decided by using the solar radiation of design point, which is defined as the sum of average and standard deviation $\sigma$ of maximum direct solar radiation distribution for a day during a year in the respective test site. It is found that the average power output during the system operating time in the case of slope error ${\sigma}_s=2.5$ is within the range of 9 to 13 kW.

  • PDF

A study on reducing temperature rise of twin-glass evacuated tube solar collector during summer time (이중진공관형 태양열 집열기의 하절기 과열 방지에 대한 연구)

  • Bai, Sang-Eun;Bai, Cheol-Ho;Nam, Hyun-Kyu;Shin, Ki-Yeol;Yoo, In-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.36-41
    • /
    • 2013
  • The reflection plate in twin-glass evacuated tube solar collector is controlled to reduce the overheat during the summer time. The sliding type and folding types are suggested and tested. The sliding type changes the plate angle and the folding type changes the opening angle of the reflection plate. By scattering the focus of the reflected radiation from the reflection plate, the temperature rise of the working fluid can be reduced. The sliding type shows the best results in overheat reduction. When solar radiation is 900 $W/m^2$, the temperature rise in one sliding type collector is reduced about $2^{\circ}C$ compared to that of the normal solar collector. When this method is applied to seven series-collectors in the field, the reduction of temperature rise during the summer time should be significant.

Study on Performance Evaluation and Efficiency Comparison for Solar Collector with Thermosyphon Tube-type (태양열집열기의 성능평가 및 열사이폰관형 집열기의 효율 비교 연구)

  • Sim, Han-Sub;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.175-182
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to make the system of performance test for solar collector and to investigate thermal efficiency for solar collector with thermosyphon tube-type. As a result, in case of indoors measurement using halogen lamp, thermal efficiency for solar collector with thermosyphon tube-type was increased about 15~22% after 120 minutes compared with that of solar collector with double evacuated tube-type. In addition, in case of outdoors measurement, thermal efficiency of thermosyphon tube-type was showed maximum about 46% higher than double evacuated tube-type.

Solar District Heating System (지역난방용 태양열시스템)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man;Sin, U-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

A Study on the Flat-Plate Solar Collector Performance taking into account of the Collector Thermal Capacitance (집열기(集熱器) 열용량(熱容量)을 고려(考慮)한 평판형집열기(平板型集熱器) 성능(性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Yong, Ho-Taek;Seoh, Jeong-Ill
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 1982
  • This paper presents the performance of a Flat-Plate Solar Collector in case of taking into account of the thermal capacitance. The relationships among energy absorption, overall heat loss coefficient and temperature distribution are studied theoretically. And the thermal capacitance of the collector is considered. Also, the results obtained are compared with those of model in which the thermal capacitance is neglected. As the results of this study, the efficiency of the collector having double glazing is higher than the other cases. It is shown that the fluid temperature in the tubes are rising close to linearly. The variations of the outlet temperature of tubes in the model neglecting the effect of thermal capacitance are tend to represent lower slope than that of considering the effect of thermal capacitance.

  • PDF

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation (파사드 일체형 자연순환 태양열온수기 유동해석)

  • Baek, Nam-Choon;Lee, Wang-Je;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

An Experimental Study of Solar fir Roof Heating System With PVT Collector (공기식 집열 지붕 난방시스템의 실험 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF