• 제목/요약/키워드: solar collector

Search Result 442, Processing Time 0.027 seconds

Performance Ratings According to Characteristics of Thermosyphon Solar Hot Water System (자연대류형 태양열온수기의 특성별 성능평가에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Yoo, C.G.;Yoon, H.G.;Kang, M.C.;Lee, D.G.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.9-17
    • /
    • 2000
  • To obtain thermal performance data, an experiment was performed with the two selected thermosyphon systems. The system parameters obtained by experimental data were used to perform TRNSYS simulation and verified TRNSYS model of thermosyphon solar hot water system. The thermosyphon solar hot water system was TYPE 145 which is modified from non-linear model. This model can describe heat exchange type and non-linear efficiency equation. It is possible to analyze the annual energy rate with efficiency equation and system specification. In this paper, we could compare the annual performance of the coil heat exchanger with that of the tank-in-tank heat exchanger. Under the same efficiency and parameter, heat exchange, drain, initial tank temperature, ratio of tank volume over collector area(V/Ac), regional annual performance rating were performed.

  • PDF

Heat Losses from the Receivers of a Multifaceted Parabolic Solar Energy Collecting System

  • Seo, Taebeom;Ryu, Siyoul;Kang, Yongheock
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.8
    • /
    • pp.1185-1195
    • /
    • 2003
  • Heat losses from the receivers of a dish-type solar energy collecting system at the Korea Institute of Energy Research (KIER) are numerically investigated. It is assumed that a number of flat square mirrors are arranged on the parabolic dish structure to serve as a reflector. Two different types of receivers, which have conical and dome shapes, are considered for the system, and several modes of heat losses from the receivers are thoroughly studied. Using the Stine and McDonald model convective heat loss from a receiver is estimated. The Net Radiation Method is used to calculate the radiation heat transfer rate by emission from the inside surface of the cavity receiver to the environment. The Monte-Carlo Method is used to predict the radiation heat transfer rate from the reflector to the receiver. Tracing the photons generated, the reflection loss from the receivers can be estimated. The radiative heat flux distribution produced by a multifaceted parabolic concentrator on the focal plane is estimated using the cone optics method. Also, the solar radiation spillage around the aperture is calculated. Based on the results of the analysis, the performances of two different receivers with multifaceted parabolic solar energy collectors are evaluated.

A Numerical Study on the Thermal Characteristics of Double Skin Vacuum Tubes with Coaxial Fluid Conduit (등축 유로 장착 이중 태양열 진공관의 열적 특성에 관한 수치해석적 연구)

  • Hyun, Jun-Ho;Park, Youn-Cheol;Chun, Won-Gee;Lee, Sang-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.567-570
    • /
    • 2006
  • A numerical study has been carried out for a solar water heater which consists of double skin solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is tilled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing double skin solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show a good agreement when compared with other experimental data demonstrating the reliability of the one-dimensional model employed.

  • PDF

CFD Analysis for Spiral-Jacketed Thermal Storage Tank in Solar Heating Systems (태양열 시스템에 적용된 나선재킷형 축열조의 CFD 해석)

  • Nam, Jin-Hyun;Kim, Min-Cheol;Kim, Charn-Jung;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.645-653
    • /
    • 2008
  • Spiral-jacketed thermal storage tanks can greatly simplify solar heating systems while maintaining the thermal performance at a similar level as conventional systems with an external heat exchanger. Proper design of the spiral-jacket flow path is essential to make the most of solar energy, and thus to maximize the thermal performance. In the present work, computational fluid dynamics (CFD) analysis was carried out for a spiral-jacketed storage tank installed in a solar heating demonstration system. The results of the CFD analysis showed a good agreement with experimentally determined thermal performance indices such as the acquired heat, collector efficiency, and mixed temperature in the storage tank. This verified CFD modelling approach can be a useful design tool in optimizing the shape of spiral-jacket flow path and the flow rate of circulating fluid for better performance.

An Experimental Study on the Condensation Characteristics of Sea Water in the Tilted Box with Solar Radiation (태양열을 받는 경사진 육면체 내 해수의 응축특성에 관한 실험적 연구)

  • Kim, Beom-Han;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.27-33
    • /
    • 2011
  • To find effective way of the production of distilled water for drought and flood with solar radiation, three boxes were made same base each 1000mm ${\times} $1000mm and tops are 45 degree. Individual boxes contained the sea water, rain water and surface water were placed at the same location and same time. Condensation of each box has been compared. On clear day production of distilled water in the box with sea water was 36% and 32% less than boxes with rain water and surface water. The maximum condensation reached when the temperature of the top and bottom parts are equal. As concentration of sea water increased production of distilled water was decreased. In the box with sea water, the surface temperature was lower than 3cm below the surface. Optimum collector area for producing distilled water 2000ml of these three boxes were $3.75m^2$

Comparative properties for a serial-parallel connection of DSSC with CNT and Pt counter electrodes (CNT 및 Pt을 상대전극으로 하는 DSSC의 직병렬연결에 관한 비교특성)

  • Kim, Hee-Je;Kim, Jeong-Hoon;Park, Sung-Jun;Choi, Jin-Young;Hong, Ji-Tae;Lee, Dong-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1236-1237
    • /
    • 2008
  • Carbon nanotube(CNT) materials are expected a stable current collector without the phenomena such as oxidizing and melting of grid by redox electrolyte and with low cost. In this paper, two types of dye-sensitized solar cells(DSSCs) with Pt abd CNT as a counter electrode were fabricated, then the energy conversion efficiency characteristics were investigated. The main purpose of this study is to find out the possibility of CNT material as cheap current collector of a large scale DSSC module. In addition, the Hall coefficient were measured by using FCM analysis.

  • PDF

A Study on Light Collector and Luminaire Design using Microstructured Film (미세 필름을 이용한 집광 및 조명장치 연구)

  • Jeong, Hak-Geun;Jung, Bong-Man;Han, Su-Bin;Lee, Euy-Jun
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its cost has been key issue due to difficult design and control of the heavy light collecting system. One of the solutions for the heavy design issues would be using a light framed film such fresnel and prism lens. Prism light guide luminaires have for some time been used to distribute light when it is desirable to have remote light sources. These systems are helpful when it is desirable to have fewer light sources, and/or to position light sources in places where lamp maintenance is easier, or electrical hazard is reduced. This proposed prototype system consists of light collector, light transformer and light pipe.

Study on Thermal Performance Characteristics of CPC System Depending on Weather Conditions and Capacity of Heat Storage Tank (기상 조건과 축열조 용량에 따른 복합 포물형 집열기(CPC) 시스템의 열적 성능 특성에 관한 연구)

  • LIM, SOK-KYU;JUNG, YOUNG GUAN;KIM, KYOUNG HOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.58-66
    • /
    • 2019
  • Static compound parabolic collectors (CPCs) have advantages such as ease for fabrication and lower cost compared with other concentrating collectors. In this study, thermal performance analysis of CPC employing heat storage tank was carried out. The clearness index and capacity of heat storage tank are taken as the main parameters for numerical simulation. The effects of the parameters on the hourly and daily system performances ncluding the useful energy, heat loss, and collector efficiency were numerically investigated. Results showed that the system has a potential for efficient recovery of solar thermal energy.

The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water (콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석)

  • Baek, Nam-Choon;Jeong, Seon-Yeong;Yoon, Eung-Sang;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

Design and Utilization of Solar Collector for Drying Agricultural Products (농산물(農産物) 건조(乾燥)를 위(爲)한 태양열(太陽熱) 집열기(集熱機)의 제작(製作) 및 이용(利用)에 관(關)한 연구(硏究))

  • Koh, Hak Kyun;Kum, Dong Hyeug
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.48-57
    • /
    • 1982
  • In order to improve the quality of traditionally sun-dried red peppers and to increase the efficiency of drying performance, three types of solar dryers were designed and built, and drying performance of the solar dryers was compared to traditional sun drying. Results obtained from the experiment are summarized as fallows: 1. The air temperature and relative humidity profiles over a 8-hour period measured at the specified locations in the drying chamber of solar dryers appeared to have large variation in each dryer. The rate of drying increased with the temperature rise in the drying chamber of the solar dryer. 2. In general. drying with solar dryers proceeded faster than traditional sun drying. With A'-type of solar dryer developed in the second experiment it was possible to dry red peppers in seven days from an initial moisture content of 80% to safe storage conditions. The drying time with the A'-type solar drier was 50% shorter compared to traditional sun drying. 3. Red peppers appeared to have an increasing or constant-rate drying period until the weight of the product was reduced to about one half the initial weight, followed by a falling-rate drying period. When the dried red peppers were exposed to the atmospere during the night, the moisture content increased as much as 6%, which is much higher than for the grains. 4. It was suggested from the experiment that either a heat storage system or a supplemental heating system in the solar dryer was desirable for more efficient drying operation. 5. It was shown that the solar dryer developed in this study may be suitable for drying other vegetables and fishes, and also offered additional advantages of saving in drying time, maintaining sanitation and minimizing contamination by dust, insects and unfavorable weather condition.

  • PDF