• Title/Summary/Keyword: solar collector

Search Result 442, Processing Time 0.026 seconds

A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region (방위각 및 경사각을 고려한 지역별 태양광 모듈 배치안 검토)

  • Park, Sung-Hyun;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.461-466
    • /
    • 2012
  • Recently, building energy systems with solar collector and solar module have increased to improve energy problem, a heat island, a global warming and carbon dioxide emissions. In this study, value of solar radiation in areas was analyzed using TRNSYS simulation, and the optimum tilt and orientation angle for installing a photovoltaic module was examined. Average values of the weather data in the past twenty years in areas were used as input data. The results show that the tilt angle of a photovoltaic module for gaining the annual maximum solar radiation varies in different localities, and values of the annual solar radiation gained by using the variable photovoltaic module increased by 2.5 percent as compared with that gained by using the fixed photovoltaic module. When fixed photovoltaic module is installed, it should be examined the tilt and orientation angle for installing a photovoltaic module was examined.

Fluid Sensor and Algorithm for Trouble Detection of Solar Thermal System (태양열 시스템 고장진단을 위한 유체센서와 알고리즘)

  • Lee, Won-Chul;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.351-356
    • /
    • 2014
  • Typical trouble patterns in solar thermal systems include working fluid leakage and freezing other than breakdown of pump. A fluid sensor for measuring electric resistance of fluid was developed and installed at the top of the collector piping in order to check the fault of solar system. Working fluid level in the pipe was determined by measuring electric resistance from a fluid sensor. On the base of this, it was confirmed that the fluid sensor diagnoses leakage of fluid. Electric resistance of propylene glycol aqueous solution was measured in the range of $0{\sim}70^{\circ}C$ and 0~40% of concentration. The response surface analysis was performed by using a central composite design, and the regression equation was derived from the relationship between electric resistance, temperature, and concentration. Through the experiment in a real solar system, we can estimate a concentration of working fluid when a pump is not operating and predict a possibility of freezing. Finally, an effective algorithm for trouble shooting was proposed to operate and maintain the solar system.

Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors (물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

A development of solar hot water system for anchovy proceeding (멸치가공을 위한 태양열 온수기 개발)

  • Kong, T.W.;Ji, M.K.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.671-676
    • /
    • 2001
  • This study are development results of solar hot water system for anchovy proceeding. The heat amounts of boiling vessel are calculated 292.66W at forward and backward direction, and surface direction are calculated 373.14W. The polyenoic rate of anchovy are measured lower as high temperature, but monoenoic and polyacid are higher. Then the others. The maximum radiation of anchovy fishing grounds are shown $350kcal/m^2h$ at pm. 13:00, Chungdo in CHINA. Distributions of Velocity and temperature in boiling vessel are calculation. Solar collector and boiling vessel for anchovy proceeding ship are developed to automatic control system.

  • PDF

Heat Transfer in a Horizontal Mantle Heat Exchanger for a Thermosyphon-driven Flat Plate Collector (자연대류형 태양열 온수기용 맨틀 축열조의 열전달 현상에 관한 연구)

  • Cho, H.J.;Seo, T.B.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.43-50
    • /
    • 2001
  • A horizontal mantle heat exchanger for a thermosyphon-driven SDHW(solar domestic hot water) was numerically simulated and fluid flow and heat transfer in the annulus of the mantle heat exchanger were quantitatively investigated. The Reynolds number, the location of the inlet, and the gap of the annulus were selected as the important design variables. The effects of the design variables on the heat transfer characteristics were thoroughly studied. Based on the numerical results, a correlation for predicting the heat transfer coefficient was suggested as the conclusion of this study.

  • PDF

Tracepro Simulation Design and Evaluation for the Double Blind Light Pipe Daylighting System (Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가)

  • Kang, Eun-Chul;Lee, Euy-Joon;Yo, Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.515-520
    • /
    • 2012
  • A daylighting system includes three parts; light collector, light transformer and light distributor. A DBLP(Double blind light pipe) daylighting system consists of a double blind light collector, a mirror duct type light transformer and a prism film light pipe distributor. The double blinds for a light collection are used to track the sun's altitude and azimuth movements throughout the day. Behind both sets of blinds is the light transformer, which is based on a rectangular cone shaped light duct. The light transformer was designed to efficiently deliver the light into the light pipe within a 30 degree radial spread for the efficient light into the distributor. In this study, DBLP system efficiency was simulated, evaluated and optimized by Tracepro as a popular ray trace light design simulation program. The results indicated that DBLP system efficiency evaluated a maximum 22.4% in case of Spring/Fall season solar noon time. While the overall average system efficiency in the morning and afternoon is evaluated about 10%.

A Comparative Study on the Characteristics of the Pure water and Ethanol Carbon Nanofluids for Applying Solar Collector (태양열 집열기 적용을 위한 순수 물과 에탄올 탄소나노유체의 특성 비교 연구)

  • An, Eoung-Jin;Park, Sung-Seek;Chun, Won-Gee;Park, Yoon-Chul;Kim, Nam-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.194-199
    • /
    • 2012
  • In this study, for increasing the efficiency of solar collector, the thermal conductivities and viscosities of the pure water and ethanol oxidized multi-walled carbon nanofluids were measured. Nanofluids were manufactured by ultra-sonic dispersing oxidized multi-walled carbon nanotubes(OMWCNTs) in the pure-water and ethanol at the rates of 0.0005 ~ 0.1 vol%. the Thermal conductivities and viscosities of manufactured nanofluids were measured at the low temperature($10^{\circ}C$), the room temperature($25^{\circ}C$) and the high temperature($70^{\circ}C$). For measuring thermal conductivity and viscosity, we used Transient Hot-wire Method and Rotational Digital Viscometer, respectively. As a result, under given temperature conditions, thermal conductivity of the 0.1 vol% pure-water nanofluid improved 7.98% ($10^{\circ}C$), 8.34% ($25^{\circ}C$), and 9.14% ($70^{\circ}C$), and its viscosity increased by 37.08% ($10^{\circ}C$), 33.96% ($25^{\circ}C$) and 21.64% ($70^{\circ}C$) than the base fluids. Thermal conductivity of the 0.1 vol% ethanol nanofluids improved 33.72% ($10^{\circ}C$), 33.14% ($25^{\circ}C$), and 32.36% ($70^{\circ}C$), and its viscosity increased by 37.93% ($10^{\circ}C$), 31.92% ($25^{\circ}C$) and 29.42% ($70^{\circ}C$) than the base fluids.

  • PDF

Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors (평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구)

  • 윤석범;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.579-589
    • /
    • 1985
  • The storage tank of the natural-circulation-solar-hot-water system equipped with flat-plate solar collectors is located at higher elevation than the solar collectors. Therefore, the heat loss from the system due to a reversed flow during the night-time is an important factor as well as the day-time thermal performance of the system. The thermal performance of the natural-circulation-solar-hot-water system with flat-plate solar collectors during the day-time depends mainly on the heat collecting efficiency of the solar collectors, whereas its thermal performance during the night-time depends on the system configuration , such as the elevation of the water storage tank with respect to the solar collectors and the piping connections between the storage tank and the solar collectors, as well as thermo-physical properties of the circulating fluid. In the present work, a computer program has been developed to simulate a typical natural-circulation-solar-hot-water-system, and a series of simulation tests have been carried out with the computer program to examine the thermal performance of the system during the day-time as well as the hight-time. In addition , a series of experiment have been conducted under a real sun condition using a natural-circulation-solar-hot-water-system constructed and installed at the KAIST building to compare with the results obtained from computer simulations.

Effect of structure configurations and wind characteristics on the design of solar concentrator support structure under dynamic wind action

  • Kaabia, Bassem;Langlois, Sebastien;Maheux, Sebastien
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.41-57
    • /
    • 2018
  • Concentrated Solar Photovoltaic (CPV) is a promising alternative to conventional solar structures. These solar tracking structures need to be optimized to be competitive against other types of energy production. In particular, the selection of the structural parameters needs to be optimized with regards to the dynamic wind response. This study aims to evaluate the effect of the main structural parameters, as selected in the preliminary design phase, on the wind response and then on the weight of the steel support structure. A parametric study has been performed where parameters influencing dynamic wind response are varied. The study is performed using a semi-deterministic time-domain wind analysis method. Unsteady aerodynamic model is applied for the shape of the CPV structure collector at different configurations in conjunction with a consistent mass-spring-damper model with the corresponding degrees of freedom to describe the dynamic response of the system. It is shown that, unlike the static response analysis, the variation of the peak wind response with many structural parameters is highly nonlinear because of the dynamic wind action. A steel structural optimization process reveals that close attention to structural and site wind parameters could lead to optimal design of CPV steel support structure.