• Title/Summary/Keyword: solar collector

Search Result 442, Processing Time 0.023 seconds

Simulation and Model Validation of a Parabolic Trough Solar Collector for Water Heating

  • Euh, Seung-Hee;Kim, Dae Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.17-26
    • /
    • 2013
  • The aim of this study is to analyze the performance of a parabolic trough solar collector (PTC) for water heating and to validate the model performance. The simulated model was compared, calibrated and verified with the experimental results. RMSE (Root mean square error) was used to calibrate the convective heat transfer coefficient between the absorber pipe and the ambient air which was the main factor affecting the heat transfer associated with the PTC. The calibrated model was better fitted with the experimental model. The maximum, minimum and mean deviation between the measured and predicted water temperatures differed only $0.81^{\circ}C$, $0.09^{\circ}C$ and $0.31^{\circ}C$ respectively in the calibrated model. RMSE values were decreased from 0.5389 to 0.4910, 0.0134 to 0.0125 and R-squared was increased from 0.9955 to 0.9956 after calibration. The temperature of water was increased from $33.7^{\circ}C$ to $48^{\circ}C$ in 12hour test. The thermal efficiency of the collector was calculated to be 55%. The calibrated model showed good agreement with the experimental data for model validation.

A Study on the Solar Water Heating System in the Military Facilities (병영시설의 태양열급탕시스템에 관한 연구)

  • Kim, Doo-Chun;Seo, Jin-Seok
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.4
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

A Study on the liquid Type Solar Heating System (액체식 태양열난방계통에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.4
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF

Fixed Bed Drying of Sugarcane Bagasse Using Solar Energy

  • Hyoung-Woo LEE;Hyun-Ook KIM;Dong-Hoon LEE;Don-Ha CHOI;Seung-Gyu KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.47-57
    • /
    • 2024
  • Solar energy is one of the most promising options for renewable energy and biomass is one of them. One of the main biomass sources, sugarcane bagasse, is produced annually in more than hundreds of nations worldwide exceeding 4.25 billion tons. To dry a 900-mm deep fixed bed of wet sugarcane bagasse, a solar air heater with a collector area of 2 m2 was installed. Between October 10th to 19th in Gwangju, South Korea, a 9-day drying period, the solar collector received a total of 496,145 kJ of solar radiation. During this time, 54.5 kg of water was extracted from 133 kg of wet sugarcane bagasse (average green moisture content of 47.6%w.b.). The estimated net heat from the evaporation of water removed during the dying period accounted for approximately 27% of the total solar radiation on the solar collector.

The Study of The Collector Efficiency Curve (태양열 집열기 효율곡선에 대한 연구)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.198-202
    • /
    • 2014
  • In the solar heat collection system, we can determine how the collector will perform under specific conditions from the efficiency curve. By understanding the basic principles which govern the operation, designers can maximize the output from the collector. Absorptance, transmission and the total heat transfer coefficient were introduced to induce this efficiency curve. Designers who can make use of the implicit information on the curve in this report will generate systems which obtain the best return from their client's investment.

Performance Analysis of R-134a Rankine Cycle to Apply for a Solar Power Generation System Using Solar Collector Modeling (태양열 집열기 모델링을 활용한 발전용 R134a 랭킨사이클의 성능해석)

  • Joung, Jinhwan;Kang, Byun;Tong, Yijie;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.57-65
    • /
    • 2014
  • As the environmental regulations is more strengthened, the study of the renewable energy system and waste heat for electricity production is being accelerated. In this study, the performance and power generation rate of solar power generation by using R134a Rankine cycle was analyzed with solar radiation and mass flow rate of R134a. As a result, the maximum and minimum collected heat of solar collector was 20.4 kW and 13.6 kW at October and December, respectively. Besides, the highest generator power was generated at October and it was 0.91 kW/day, while the lowest generator power is occurred at December and it was about 0.85 kW/day.

Evaluation of thermal performance for solar cooling and heating system (태양열 냉.난방 및 급탕 시스템 열성능)

  • Kwak, Hee-Youl;Joo, Hong-Jin;Lee, Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.203-208
    • /
    • 2009
  • This paper presents demonstration study results derived through field testing of a solar assisted cooling and heating system for the library of a cultural center building located in Gwangju, Korea. The area of demanded cooling and heating for building was about 350m2. Solar hot water was delivered by means of a 200m2 array of evacuated tubular solar collector (ETSC) to drive a single-effect (LiBr/H2O) absorption chiller of 10RT nominal cooling capacity. From March in 2008 to February in 2009, demonstration test were performed for solar cooling and heating system. After experiments and analysis, this study found that solar thermal system was 84% for the solar hot water supply and 12% for space heating and 4% for space cooling.

  • PDF

A Study on the Performance of Flat-Plate Solar Collector with Rectangular Channels (사각관을 이용한 태양열집열기의 성능에 관한 연구)

  • Lee Sang Chun;Cha Jong Hee;Bae Soon Hoon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.2
    • /
    • pp.91-98
    • /
    • 1977
  • For the cost reduction of a flat-plate solar collector, a new galvanized iron collectro plate replaced the convenctional copper or alnminum collector plates and the flow channel was also modified to a rectangular channel for a better heat transfer performance. A simple analytical model was developed and agreed well with the experimental results. The results show better thermal performance for a rectangular channel than for a conventional circular channel.

  • PDF

Analysis of Solar Radiation and Heat-Efficiency in Semi-Greenhouse Type Solar-Dehumidification Lumber Dryer (반온실형(半溫室型) 제습(除濕).태양열(太陽熱) 목재(木材)드라이어의 일사량(日射量)과 열효율분석(熱效率分析)에 관(關)한 연구(硏究))

  • Lee, Hyoung-Woo
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.3-12
    • /
    • 1989
  • Semi-greenhouse type solar-dehumidification drying of oak was carried out to investigate the possibility to dry wood using solar energy in Korea. The energy balance equation was set up, considering all the energy requirements, and the solar radiation was calculated to analyze the efficiencies of solar dryer with and without the dehumidifier. The average temperature inside dryer and collector rose up to $52^{\circ}C$ and $70^{\circ}C$, respectively. The average daily total beam, diffuse, and ground-reflected radiations were 7.27MJ, 8.70MJ, and 0.33MJ on the roof and 2.08MJ, 4.84MJ, and 5.37MJ on the south wall collector, respectively. Heat efficiency of solar dryer was 14.04% with dehumidifier and 13.13% without dehumidifier. The energy required to remove 1g of water from wood was 0.0289MJ/g in solar-dehumidification drying and 0.0310 MJ/g in semi-greenhouse type solar drying.

  • PDF