• Title/Summary/Keyword: soil penetration

Search Result 517, Processing Time 0.025 seconds

Analysis of load-settlement behaviour of shallow foundations in saturated clays based on CPT and DPT tests

  • Mir, Mouna;Bouafia, Ali;Rahmani, Khaled;Aouali, Nawel
    • Geomechanics and Engineering
    • /
    • v.13 no.1
    • /
    • pp.119-139
    • /
    • 2017
  • Static Penetration Test (CPT) and Dynamic Penetration Test (DPT) are commonly used in-situ tests in a routine geotechnical investigation. Besides their use for qualitative investigation (lithology, homogeneity and spatial variability), they are used as practical tools of geotechnical characterization (resistance to the penetration, soil rigidity) and modern foundation design as well. The paper aims at presenting the results of an extensive research work on the evaluation of the 1D primary consolidation settlement of saturated clayey soils on the basis of the CPT or DPT tests. The work is based on an analysis of the correlations between the tip resistance to penetration measured in these tests and the parameters of compressibility measured by the compressibility oedometer test, through a local geotechnical database in the northern Algeria. Such an analysis led to the proposal of two methods of calculation of the settlement, one based on the CPT test and the other one on the DPT. The comparison between the predicted settlements and those computed on the basis of the oedometer test showed a good agreement which demonstrate the possbility to use the CPT and DPT tests as reliable tools of computation of foundation settlements in clayey soils.

Effect of water jetting parameters on the penetration behavior of jack-up spudcan in surficial sand condition

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-19
    • /
    • 2015
  • The water jetting system for a jack-up spudcan requires the suitable design considering the platform/spudcan particulars, environments, and soil conditions, either the surficial clay or surficial sand. The usage of water jetting depends critically on soil conditions. The water jetting is usually used for the smooth and fast extraction of the spudcan in the surficial clay condition. It is also required for inserting spudcan up to the required depth in the surficial sand condition, which is investigated in this paper. Especially, it should be very careful to use the water jetting during an installation of spudcan in the surficial sand condition, because there is a risk of overturning accident related to the punch-through. Therefore, in this study, the effect of water jetting flow rate and time on the change of soil properties and penetration resistance is analyzed to better understand their interactions and correlations when inserting the spudcan with water jetting in surficial sand condition. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the multi layered soil (surficial sand overlaying clays) is considered as the soil condition. The environmental loading and soil-structure interaction (SSI) analysis are performed by using CHARM3D and ANSYS. This kind of investigation and simulation is needed to decide the proper water jetting flow rate and time of spudcan for the given design condition.

Face Stability Assessment of Slurry-shield Tunnels - Concentrating on Slurry Clogging Effect - (슬러리 쉴드 터널의 막장 안정성 평가 - 슬러리의 폐색효과를 중심으로 -)

  • Lee, In-Mo;Lee, Sam;Cho, Kook-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.95-107
    • /
    • 2004
  • In this paper, the rheological characteristics of slurry used fur slurry-shield tunnels were studied with emphasis on penetration characteristics. The slurry penetration was modeled by soil-filter clogging theory. The coefficient of particle deposition was suggested as an indicator of sin clogging during tunnel construction and calculated through model tests. The measured slurry weight, clogged in the base soil, was compared with the value obtained from clogging theory. Based on the testing results, a stability analysis of a tunnel face was performed to pinpoint the most influential factor affecting stability of slurry-shield tunnels. It was found that the stability of tunnel face is dependent on the ratio of infiltration velocity to the coefficient of particle deposition, and the penetration distance of slurry increases with the ratio of infiltration velocity to the coefficient of particle deposition. Since the stability of tunnel face decreases with the slurry penetration distance, it was necessary to add some additives in order to reduce the slurry penetration distance. It was found that the ground condition needs additives when the soil has the effective particle diameter$(D_{10})$ larger than 0.75mm. It was also found that the tunnel face stability due to slurry penetration is significantly affected by the tunnel advance rate.

Dilatometer test for evaluating deformation characteristics in sand (사질토의 변형특성 평가를 위한 딜라토미터 시험의 활용)

  • Lee, Moon-Joo;Hong, Sung-Jin;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.241-252
    • /
    • 2010
  • This study investigates the application of dilatometer test for evaluating the deformation characteristics of granular soil. $K_D$ is the most sensitive to the stress history among CPT and DMT measurements, and $E_D$ and $q_c$ are observed to be similarly affected by the stress history. The coefficient of at-rest earth pressure($K_0$) is an indirect measure evaluating the stress history of granular soil. A relation using only DMT indices provides appropriate prediction of $K_0$ values. Although penetration of dilatometer inevitably induces the failure of cementation bonds, $E_D$ reflects the deformation characteristics of undamaged cementation relatively well. Therefore, a slightly better prediction of M value for cemented sand is achieved by using $E_D$ rather than $q_c$. Because of the weaker particle strength of calcareous sand compared than quartz sand, the majority of sand particles adjacent to dilatometer probe will be crushed during penetration. The particle crushing will induce the less contraction of the dilatometer membrane during penetration, consequently, the smaller $K_D$ and $E_D$ of calcareous sand.

  • PDF

Soil Resistant and Blood Repellent Finishes of Nonwoven Fabrics Using Foam (거품을 이용한 부직포의 방오방혈가공)

  • 이정민;배기서;노덕길;전병열
    • Textile Coloration and Finishing
    • /
    • v.4 no.3
    • /
    • pp.74-81
    • /
    • 1992
  • Chemical bonded nonwoven fabric for apparel use and spunlaced nonwoven fabric for medical use were finished for soil resistance and blood replellency with fluorochemicals utilizing foam finishing technology (FFT) and conventional padding application techniques. The FFT process improved soil and abrasion resistance properties of nonwoven fabrics compared with the conventional padding process. Excellent water-oil-saline-alcohol repellency values and water impact penetration values were obtained in the spunlaced nonwoven fabrics with both techniques.

  • PDF

Evaluation of Ground Improvement on Sands at Yongjong Island Geotechnical Experimental Site (영종도 지반공학 야외시험장에서의 사질토지반 개량효과 평가)

  • 김동수;박형춘;김영웅;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.439-446
    • /
    • 1999
  • In situ experimental studies were Performed at Yongjong Island Geotechnical Experimental Site to evaluate the ground densification on sand deposited. Standard penetration test, cone penetration test, and SASW test were performed and soil profiles and quality of ground improvements were evaluated. The feasibility of applying SASW method were verified by comparing test results. The evaluation technique of in-situ density using SASW and resonant column tests was proposed, and the reliability of proposed method was verified by performing case studies.

  • PDF

Study on Cone Penetration Rate and Anisotropy in Cohesive Soils (점성토에 있어서 지반의 비등방성을 고려한 콘 관입속도에 관한 연구)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.559-566
    • /
    • 2000
  • 본 연구에서는 비등방성 응력조건 하에서 콘 관입속도가 콘 관입시험 결과에 미치는 영향을 연구하기 위하여 유한요소해석 및 Calibration Chamber를 이용한 Miniature Piezocone의 관입시험이 수행되었으며 그 결과를 비교 분석하였다. 비등방성을 고려하기 위하여 Anisotropic Soil Model이 유한요소해석에 이용되었으며 LSU/CALCHAS(Louisiana State University Calibration Chamber System)가 Miniature Piezocone의 관입시험에 이용되었다. 콘 관입속도의 영향이외에도 OCR 및 필터위치의 영향을 고찰하였다.

  • PDF

Estimation of compressibility for Busan clay by CPT (CPT를 이용한 부산점토의 압축특성에 관한 연구)

  • Hong, Sung-Jin;Lee, Moon-Joo;Shim, Seong-Hyeon;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.320-325
    • /
    • 2009
  • The constrained modulus, representative property to evaluate compressibility of soil, is needed to estimate the settlement of ground structure. A series of lab and field cone penetration tests for clayey soil of Busan new-port and Noksan industrial area were conducted to evaluate the estimation method of constrained modulus. Since CPT generates large deformation of ground, it is difficult to correlate the cone resistance with the constrained modulus. Therefore, appropriate correlation between them is essential to estimate the constrained modulus based on CPT results. The test results show that the ratio of the constrained modulus to the cone resistance is inversely proportional with plasticity index. Based on this result, the estimation method of constrained modulus for Busan clay is suggested.

  • PDF

Analysis of Application Cases and Evaluation of Effectiveness on Portable Dynamic Cone Penetration Test (DCPT) to Identify the Deterioration Cause of Damaged Reinforced Earth Walls (보강토옹벽의 피해원인 규명을 위한 휴대형 동적콘관입시험(DCPT) 적용사례 분석 및 효용성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.95-109
    • /
    • 2020
  • In this study, a total of six site cases were reviewed to assess the site applicability of portable dynamic cone penetration test (DCPT) by identifying the cause of damage to the damaged reinforced earth wall using portable dynamic cone penetration test. An improved dynamic concrete penetration tester was used at the site to enable ground surveys of more than 6 meters. The test results were compared with the results of the standard penetration test (SPT) and the correlation was analyzed. Through the analysis of various field application cases, it was found that portable dynamic cone penetration test was very convenient to apply at the site of the damaged reinforced earth wall, and DCPT could play a major role in identifying the cause of damage and verifying stability of the retaining wall by continuously identifying the ground strength. In addition, it was found that the results of the dynamic cone penetration test and the standard penetration test showed a correlation of N≒(1/3~2/3)·Nd in sandy soil.

Development of Unmanned Seabed type Marine Cone Penetration Testing System (무인 착저식 해양 콘관입시험기 개발)

  • Jang, In-Sung;Kwon, O-Soon;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.611-622
    • /
    • 2007
  • In the design and construction of the coastal/offshore structures, it is very important to evaluate the geotechnical characteristics of marine soils, which support the structures. Although the offshore site investigation is much more difficult than onshore, safe and precise jobs have not been accomplished in Korea because of the insufficiency of the test equipments especially for the site with deep water depth. The main objective of this study is to develop a new type of marine cone penetration testing(CPT) system, which can be utilized to even deep sea and high depth of soil layer. The system is one of seabed types and employs the conventional cone, which shows more reliable results than miniature cone. The most important parts of the marine CPT including continuous rod system, cone penetration system with wheel drive, automatic cone rod assembly/dissembly system etc., were designed and manufactured. Some tests to verify the developed marine CPT system were performed at both onshore and offshore sites as well as mechanical test in laboratory. The test results show the consistent and promising performance of the new equipment, and thereafter the system would be applicable to various sites with practical/economical advantages.

  • PDF