• Title/Summary/Keyword: soft tissue change

Search Result 236, Processing Time 0.028 seconds

22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesions

  • Yuki Tanisaka;Masafumi Mizuide;Akashi Fujita;Ryuhei Jinushi;Rie Shiomi;Takahiro Shin;Kei Sugimoto;Tomoaki Tashima;Yumi Mashimo;Shomei Ryozawa
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.237-245
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

Nano-Structures on Polymers Evolved by Ion Beam/Plasma

  • Moon, Myoung-Woon;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.76-76
    • /
    • 2012
  • Surface engineering of polymers has a broad array of scientific and technological applications that range from tissue engineering, regenerative medicine, microfluidics and novel lab on chip devices to building mechanical memories, stretchable electronics, and devising tunable surface adhesion for robotics. Recent advancements in the field of nanotechnology have provided robust techniques for controlled surface modification of polymers and creation of structural features on the polymeric surface at submicron scale. We have recently demonstrated techniques for controlled surfaces of soft and relatively hard polymers using ion beam irradiation and plasma treatment, which allows the fabrication of nanoscale surface features such as wrinkles, ripples, holes, and hairs with respect to its polymers. In this talk, we discuss the underlying mechanisms of formation of these structural features. This includes the change in the chemical composition of the surface layer of the polymers due to ion beam irradiation or plasma treatment and the instability and mechanics of the skin-substrate system. Using ion beam or plasma irradiation on polymers, we introduce a simple method for fabrication of one-dimensional, two-dimensional and nested hierarchical structural patterns on polymeric surfaces on various polymers such as polypropylene (PP), polyethylene (PE), poly (methyl methacrylate) PMMA, and polydimethylsiloxane (PDMS).

  • PDF

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Balcony genioplasty: a novel technique for better esthetic results in patients with deep mentolabial fold

  • Keyhan, Seied Omid;Cheshmi, Behzad;Fallahi, Hamid Reza;Asayesh, Mohammad Ali;Fattahi, Tirbod
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.7.1-7.5
    • /
    • 2019
  • Background: To introduce a novel technique for advancement genioplasty helping surgeons to avoid soft tissue difficulties especially in short-faced patients with deep mentolabial fold and everted lower lip. Case presentation: In a trapezius-shaped, osteotomy was performed in the chin region. The mobilized segment was advanced, and the existing gap was grafted using interpositional allograft materials. Each side had been fixated by three-hole plates and two screws. The outcomes revealed no change in lower anterior teeth vitality. The patients did not report any changes of sensation in lower lip and chin either. The measurements indicated no increase in depth of mentolabial fold in patients undergoing this surgical technique. The postoperative evaluation showed a successful esthetic outcome for the patient and the surgeon concurrently. Conclusion: Based on our experience, the authors concluded that the Balcony technique is a simple and reliable procedure for patients with a deep mentolabial fold.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Fall-Related Injury and Balance of the Elderly (노인의 낙상과 균형)

  • Kim On-Ju;Kim Tae-Sook;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.161-171
    • /
    • 1998
  • Balance can be defined as the ability to maintain the body's center of gravity within the base of support with minimal sway. Falls occur frequently in the elderly persons by the physiological change and dysfunction with age. Injuries resulting from falls include soft tissue damage and fractures of the radius, humerus, and femoral neck other consequences of falls include decreased mobility, reduced confidence, long lies (which can give rise to hypothermia, dehydration and pneumonia), and death Risk factors for falls have beau classified as intrinsic (those related to the individual) and extrinsic(those associated with environmental features), Intrinsic factors include decreased strength, visual deficits, vestibular dysfunction, and decreased vibratory sensation in the feet. Improvement of the balance related to the increased probability for fells in the elderly persons and is important for fall preventions and improvement of the living quality ef the elderly persons

  • PDF

A Case of Schwannoma of the Larynx (후두에 발생한 신경 초종 1례)

  • Choi, Dong-Joon;Ko, Il-Ju;Kwon, Sung-Jin;Park, Il-Seok;Kim, Beom-Gyu;Kim, Yong-Bok;Jang, Woo-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.2
    • /
    • pp.200-202
    • /
    • 2008
  • Schwannoma is a benign soft tissue tumor arising from the schwann cells of the nerve sheath. Although 25 to 45% of schwannomas arise in the head and neck region, larynx is one of the rarest sites of involvement. Recently, we experienced a case of a laryngeal schwannoma causing voice change in a 53-years-old woman. Laryngeal schwannoma is located right false vocal fold with bulging, which was completely removed by microlaryngeal surgical excision. We report a rare case with a review of literature.

Distraction Osteogenesis of Maxillary Anterior Segment in Cleft Lip and Palate Patients (구순구개열 환자에서 상악전방골 신장술)

  • Kim, Eu-Gene;Cheon, Kang-Yong;Kim, Soo-Ho;Park, Hyong-Wook;Hwang, Soon-Jung
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.2
    • /
    • pp.89-96
    • /
    • 2012
  • Le Fort 1 osteotomy or maxillary advancement with distraction osteogenesis (DO) is main treatment strategy for cleft palate patients with maxillary hypoplasia. Maxillary DO allows greater maxillary advancement within physiological limit than Le Fort 1 osteotomy. Moreover, it is better for velopharyngeal function. However, there is a greater tendency for an increase in nasal sound when maxilla is advanced excessively. Therefore, the advancement of anterior maxillary segment using DO has been utilized. It offers advantages such as an increase in the length of the palate, a prevention of the change in palatopharyngeal depth, and a preservation of the velopharyngeal function. Moreover, it will obliterate the necessity of bone graft, and it prevents the occurrence of oronasal or oroantral fistula. Finally, it stimulates the regeneration of the soft and hard tissue of alveolus, and subsequently makes possible to place implant.

  • PDF

Differential Diagnosis and Treatment of Septic Arthritis in the Temporomandibular Joint: A Case Report and Literature Review

  • Kim, Bola;Choi, Hyo-Won;Kim, Jae-Young;Park, Kwang-Ho;Huh, Jong-Ki
    • Journal of Oral Medicine and Pain
    • /
    • v.44 no.3
    • /
    • pp.127-132
    • /
    • 2019
  • Septic arthritis of the temporomandibular joint (TMJ) is an uncommon disease caused by microbial pathogens through hematogenous infection, local spread, or iatrogenic infection. As the symptoms have an insidious onset, the early stage of septic arthritis is often confused with other diseases. A 49-year-old man was referred for increasing preauricular pain, swelling, and restricted mouth opening. He had been initially diagnosed as having a conventional temporomandibular joint disorder and trigeminal neuralgia and had been treated for the same. Imaging studies including panoramic view, lateral tomography, computed tomography with contrast enhancement, and magnetic resonance imaging were performed. Erosive bone change with displacement of the involved condyle, diffuse swelling of adjacent soft tissue, and fluid collection in the joint space were noted. Needle aspiration of the joint space and bacterial culture confirmed the diagnosis of septic arthritis of the TMJ and he was treated with antibiotic therapy and surgical drainage. Clinicians should always consider the diagnosis of septic arthritis of the TMJ in patients with preauricular pain or swelling.