• Title/Summary/Keyword: soft tissue

Search Result 3,065, Processing Time 0.029 seconds

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Dependency of Generator Performance on T1 and T2 weights of the Input MR Images in developing a CycleGan based CT image generator from MR images (CycleGan 딥러닝기반 인공CT영상 생성성능에 대한 입력 MR영상의 T1 및 T2 가중방식의 영향)

  • Samuel Lee;Jonghun Jeong;Jinyoung Kim;Yeon Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2024
  • Even though MR can reveal excellent soft-tissue contrast and functional information, CT is also required for electron density information for accurate dose calculation in Radiotherapy. For the fusion of MRI and CT images in RT treatment planning workflow, patients are normally scanned on both MRI and CT imaging modalities. Recently deep-learning-based generations of CT images from MR images became possible owing to machine learning technology. This eliminated CT scanning work. This study implemented a CycleGan deep-learning-based CT image generation from MR images. Three CT generators whose learning is based on T1- , T2- , or T1-&T2-weighted MR images were created, respectively. We found that the T1-weighted MR image-based generator can generate better than other CT generators when T1-weighted MR images are input. In contrast, a T2-weighted MR image-based generator can generate better than other CT generators do when T2-weighted MR images are input. The results say that the CT generator from MR images is just outside the practical clinics and the specific weight MR image-based machine-learning generator can generate better CT images than other sequence MR image-based generators do.

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.

Sonographic Appearance of Steatocystoma: An Analysis of 14 Pathologically Confirmed Lesions (지선낭종의 초음파 소견: 조직학적으로 진단된 14개 병변의 분석)

  • Hyeyoung Yoon;Yusuhn Kang;Hwiryong Park;Joong Mo Ahn;Eugene Lee;Joon Woo Lee;Heung Sik Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.382-392
    • /
    • 2021
  • Purpose To evaluate the ultrasonographic characteristics of steatocystomas focusing on the features that aid in differentiating them from epidermal inclusion cysts and lipomas. Materials and Methods The ultrasonographic findings of 14 histologically proven steatocystomas in 10 patients were retrospectively reviewed. The following features were assessed: the layer of involvement, shape, margin, echogenicity, posterior acoustic features, and the presence of a visible wall or intralesional striations. The findings were compared with those of subcutaneous lipomas and epidermal inclusion cysts to identify those findings that aid in the differential diagnosis of steatocystomas. Results The majority of steatocystomas appeared as a subcutaneous mass (n = 6, 42.9%) or a mass involving both the dermal and subcutaneous layers (n = 6, 42.9%). Steatocystomas exhibited a well-defined smooth margin (n = 12, 85.7%) and homogeneous echogenicity (n = 9, 64.3%), and showed no specific posterior acoustic features (n = 9, 64.3%). The most important features that differentiated steatocystomas from epidermal inclusion cysts were a homogeneous internal echotexture (p = 0.009) and absent or less prominent posterior acoustic enhancement (p < 0.001). The features that distinguished steatocystomas from lipomas were the margin (p < 0.001), echogenicity (p = 0.034), internal echotexture (p = 0.004), and the absence of intralesional striations (p < 0.001). Conclusion Steatocystomas appeared as well-defined homogeneous masses with mild or absent posterior acoustic enhancement.

Pathophysiology and MRI Findings of Infectious Spondylitis and the Differential Diagnosis (감염성 척추염과 감별질환의 병태생리와 MRI 소견)

  • Sunjin Ryu;Yeo Ju Kim;Seunghun Lee;Jeongah Ryu;Sunghoon Park;Jung Ui Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1413-1440
    • /
    • 2021
  • On MRI, abnormal signals of the intervertebral disc, destruction of the upper and lower vertebral body endplate around the disc, and bone marrow edema around the endplate are considered typical findings of infectious spondylitis. These findings can also appear in various non-infectious spinal diseases, such as degenerative changes, acute Schmorl's node, spondyloarthropathy, synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO), chronic recurrent multifocal osteomyelitis, and calcium pyrophosphate dihydrate crystal deposition disease. The imaging findings of infectious spondylitis that can be differentiated from these non-infectious spinal diseases on MRI are high signal intensity and abscess of the disc space, an abscess in the paraspinal soft tissue, and the loss of the linear low signal intensity on T1-weighted images of the bony endplate. However, these differentiation points do not always apply since there are many similarities in the imaging findings of infectious and non-infectious diseases. Therefore, for an accurate diagnosis, it is important to know the imaging characteristics related to the pathophysiology of not only infectious spondylitis but also non-infectious spinal diseases, which requires differentiation from infection.

MRI Evaluation of Suspected Pathologic Fracture at the Extremities from Metastasis: Diagnostic Value of Added Diffusion-Weighted Imaging

  • Sun-Young Park;Min Hee Lee;Ji Young Jeon;Hye Won Chung;Sang Hoon Lee;Myung Jin Shin
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.812-822
    • /
    • 2019
  • Objective: To assess the diagnostic value of combining diffusion-weighted imaging (DWI) with conventional magnetic resonance imaging (MRI) for differentiating between pathologic and traumatic fractures at extremities from metastasis. Materials and Methods: Institutional Review Board approved this retrospective study and informed consent was waived. This study included 49 patients each with pathologic and traumatic fractures at extremities. The patients underwent conventional MRI combined with DWI. For qualitative analysis, two radiologists (R1 and R2) independently reviewed three imaging sets with a crossover design using a 5-point scale and a 3-scale confidence level: DWI plus non-enhanced MRI (NEMR; DW set), NEMR plus contrast-enhanced fat-saturated T1-weighted imaging (CEFST1; CE set), and DWI plus NEMR plus CEFST1 (combined set). McNemar's test was used to compare the diagnostic performances among three sets and perform subgroup analyses (single vs. multiple bone abnormality, absence/presence of extra-osseous mass, and bone enhancement at fracture margin). Results: Compared to the CE set, the combined set showed improved diagnostic accuracy (R1, 84.7 vs. 95.9%; R2, 91.8 vs. 95.9%, p < 0.05) and specificity (R1, 71.4% vs. 93.9%, p < 0.005; R2, 85.7% vs. 98%, p = 0.07), with no difference in sensitivities (p > 0.05). In cases of absent extra-osseous soft tissue mass and present fracture site enhancement, the combined set showed improved accuracy (R1, 82.9-84.4% vs. 95.6-96.3%, p < 0.05; R2, 90.2-91.1% vs. 95.1-95.6%, p < 0.05) and specificity (R1, 68.3-72.9% vs. 92.7-95.8%, p < 0.005; R2, 83.0-85.4% vs. 97.6-98.0%, p = 0.07). Conclusion: Combining DWI with conventional MRI improved the diagnostic accuracy and specificity while retaining sensitivity for differentiating between pathologic and traumatic fractures from metastasis at extremities.

Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model

  • Xuee Zhu;Jichen Wang;Dan Zhou;Chong Feng;Zhiwen Dong;Hanxiao Yu
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.641-648
    • /
    • 2019
  • Objective: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. Materials and Methods: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1-1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were rescanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. Results: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776-0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. Conclusion: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.

Multicentric Epithelioid Angiosarcoma of Bones Showing Angiotropic Spread: A Case Report (뼈에 발생한 혈관성 파종 양상을 보이는 다발성 상피상 혈관육종: 증례 보고)

  • Woo Suk Choi;Seul Ki Lee;Jee-Young Kim;Jun-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.240-246
    • /
    • 2024
  • Epithelioid angiosarcoma is a rare variant of angiosarcoma characterized by an epithelioid morphology that mimics carcinoma. Therefore, multicentric epithelioid angiosarcoma is easily misdiagnosed as bone metastasis from carcinoma and has an aggressive clinical course. Here, we present a rare case of a 61-year-old male with multicentric epithelioid angiosarcoma of the bone. Plain radiography, CT, and MRI revealed multiple osteolytic lesions in both femurs; some lesions showed soft tissue extension with cortical bone destruction. Interestingly, PET-CT revealed that the lesions were only distributed along the bones of the lower extremities, including the pelvic bones, femurs, and tibiae. Despite histological analysis initially suggesting metastatic carcinoma, after additional immunohistological staining, including that for vascular markers (CD31 and ERG), the final diagnosis was epithelioid angiosarcoma. A better understanding of the clinicoradiological features of this disease may help eliminate diagnostic confusion and provide better management.

Real-Time 3D Volume Deformation and Visualization by Integrating NeRF, PBD, and Parallel Resampling (NeRF, PBD 및 병렬 리샘플링을 결합한 실시간 3D 볼륨 변형체 시각화)

  • Sangmin Kwon;Sojin Jeon;Juni Park;Dasol Kim;Heewon Kye
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.3
    • /
    • pp.189-198
    • /
    • 2024
  • Research combining deep learning-based models and physical simulations is making important advances in the medical field. This extracts the necessary information from medical image data and enables fast and accurate prediction of deformation of the skeleton and soft tissue based on physical laws. This study proposes a system that integrates Neural Radiance Fields (NeRF), Position-Based Dynamics (PBD), and Parallel Resampling to generate 3D volume data, and deform and visualize them in real-time. NeRF uses 2D images and camera coordinates to produce high-resolution 3D volume data, while PBD enables real-time deformation and interaction through physics-based simulation. Parallel Resampling improves rendering efficiency by dividing the volume into tetrahedral meshes and utilizing GPU parallel processing. This system renders the deformed volume data using ray casting, leveraging GPU parallel processing for fast real-time visualization. Experimental results show that this system can generate and deform 3D data without expensive equipment, demonstrating potential applications in engineering, education, and medicine.