• Title/Summary/Keyword: soft film

Search Result 299, Processing Time 0.039 seconds

BGA Deveop Process Optimization for the Vertical Wet Equipment Using Taguchi Experiment (다구찌 방법을 이용한 BGA 현상 공정용 수직 습식 장비의 공정 최적화)

  • Ryu, Sun-Joong
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.310-317
    • /
    • 2009
  • Vertical wet equipment for the BGA develop process was newly developed substituted for conventional horizontal wet equipment. The benefits of vertical equipment are that the pattern damages generated by the collision between the patterns and transferring rollers can be eliminated because the direct contact between the equipment's transferring units and the soft dry film patterns does not occurs. Taguchi experiment was conducted to optimize the process characteristics for the vertical equipment. The experiment was organized as the smaller the better problem which includes adequate uncontrollable factor and controllable factors. The uncontrollable factors are the 4 sides of two panels which are loaded to the equipment at the same time. By the analysis of the experiment, temperature of the develop chemicals and develop spraying time are analyzed as the main controllable factors. Finally, line pattern's minimum width which is not damaged for the develop process was improved from $13.8{\mu}m$ for the horizontal equipment to $10.4{\mu}m$ for the vertical equipment. And dot pattern's minimum width is improved from $22.1{\mu}m$ to $16.3{\mu}m$.

Memory Effect of $In_2O_3$ Quantum Dots and Graphene in $SiO_2$ thin Film

  • Lee, Dong Uk;Sim, Seong Min;So, Joon Sub;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.240.2-240.2
    • /
    • 2013
  • The device scale of flash memory was confronted with quantum mechanical limitation. The next generation memory device will be required a break-through for the device scaling problem. Especially, graphene is one of important materials to overcome scaling and operation problem for the memory device, because ofthe high carrier mobility, the mechanicalflexibility, the one atomic layer thick and versatile chemistry. We demonstrate the hybrid memory consisted with the metal-oxide quantum dots and the mono-layered graphene which was transferred to $SiO_2$ (5 nm)/Si substrate. The 5-nm thick secondary $SiO_2$ layer was deposited on the mono-layered graphene by using ultra-high vacuum sputtering system which base pressure is about $1{\times}10^{-10}$ Torr. The $In_2O_3$ quantum dots were distributed on the secondary $SiO_2$2 layer after chemical reaction between deposited In layer and polyamic acid layer through soft baking at $125^{\circ}C$ for 30 min and curing process at $400^{\circ}C$ for 1 hr by using the furnace in $N_2$ ambient. The memory devices with the $In_2O_3$ quantum dots on graphene monolayer between $SiO_2$ thin films have demonstrated and evaluated for the application of next generation nonvolatile memory device. We will discuss the electrical properties to understating memory effect related with quantum mechanical transport between the $In_2O_3$ quantum dots and the Fermi level of graphene layer.

  • PDF

Nanostructuring the Polyimide Alignment Layer and Uniform Liquid Crystal Alignment by Solvent Assisted Micromolding (Solvent Assisted Micromolding을 이용한 Polyimide 나노구조 형성 및 이를 통한 균일 액정 배향)

  • Kim, Jongbok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.72-77
    • /
    • 2019
  • The display that provides information to us through the visual sense is a very important information transmission means by intuitively transmitting information, and the liquid crystal display (LCD) is the most widely used information transmission display. In this paper, we studied solvent assisted micromolding as an alternative for the rubbing that is essential to align the liquid crystals in LCD and successfully aligned the liquid crystal molecules by constructing the nanostructures on conventional polyimide alignment layer. When generating the nanostructures on the polyimide film, there was a competitive correlation between the dissolution effect of the polymer by the solvent and the capillary effect of the polyimide molecules into the nanostructures of the mold depending on the process temperature. It was possible to form nanostructures with high step by deriving the optimum temperature. These nanostructures were able to align the liquid crystal molecules uniformly and demonstrated that they could form a desirable pretilt angle.

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

Dose Distribution According to the Tissue Composition Using Wedge Filter by Radiochromic Film (쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구)

  • Kim, Yon-Lae;Lee, Jeong-Woo;Park, Byung-Moon;Jung, Jae-Yong;Park, Ji-Yeon;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.157-164
    • /
    • 2012
  • The purpose of this study is to analyze the dose distribution when wedge filter is used in the various tissue electron density materials. The dose distribution was assessed that the enhanced dynamic wedge filter and physical wedge filter were used in the solid water phantom, cork phantom, and air cavity. The film dosimetry was suitable simple to measure 2D dose distribution. Therefore, the radiochromic films (Gafchromic EBT2, ISP, NJ, USA) were selected to measure and to analyze the dose distributions. A linear accelerator using 6 MV photon were irradiated to field size of $10{\times}10cm^2$ with 400 MUs. The dose distributions of EBT2 films were analyzed the in-field area and penumbra regions by using dose analysis program. In the dose distributions of wedge field, the dose from a physical wedge was higher than that from a dynamic wedge at the same electron density materials. A dose distributions of wedge type in the solid water phantom and the cork phantom were in agreements with 2%. However, the dose distribution in air cavity showed the large difference with those in the solid water phantom or cork phantom dose distributions. Dose distribution of wedge field in air cavity was not shown the wedge effect. The penumbra width, out of the field of thick and thin, was observed larger from 1 cm to 2 cm at the thick end. The penumbra of physical wedge filter was much larger average 6% than the dynamic wedge filter. If the physical wedge filter is used, the dose was increased to effect the scatter that interacted with photon and physical wedge. In the case of difference in electron like the soft tissue, lung, and air, the transmission, absorption, and scattering were changed in the medium at high energy photon. Therefore, the treatment at the difference electron density should be inhomogeneity correction in treatment planning system.

Studies on the Processing and Keeping Quality of Retort Pouched Foods (2) Preparation and Keeping Duality of Retort Pouched Seasoned-Oyster Products (레토르트파우치식품의 가공 및 품질안정성에 관한 연구(2) 조미굴 레토르트파우치제품의 제조 및 품질안정성)

  • LEE Eung-Ho;CHA Yong-Jun;LEE Tae-Hum;AHN Chang-Bum;YOO Gyung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.24-32
    • /
    • 1984
  • In order to process instant foods which hold appropriate moisture contents and soft texture, four kinds of retort pouched seasoned-oyster products were prepared as control, seasoned products, solid smoked and liquid smoked product after seasoning and their processing conditions and quality stability during 100 days of storage were investigated. The optimum processing conditions of retort pouched seasoned-oyster product were as follows ; namely, raw oyster was seasoned at $105^{\circ}C$ for 10 min with seasoning solution prepared from sugar, sorbitol, salt, monosodium glutamate and 5'-ribonucleotide and then dipped for 30 seconds in Smoke-EZ solution(Alpha Foods Co., Ltd.) after predried for 30 min in hot-air drier. After. smoking, the seasoned and liquid smoked oyster was dried at $40-42^{\circ}C$ for 2.5 hours, vacuum packed in plastic film bag, and sterilized in a hot water circulating retort at $120^{\circ}C$ for 16 min. Comparing their quality before and after sterilization, TBA value of all the products after sterilization slightly decreased and among texture profiles hardness, toughness and chewiness slightly decreased, while elasticity and cohesiveness were rarely changed. Color value (a value) of the product treated with solid smoke or liquid smoke increased after sterilization. During storage pH, VBM and water activity of all products changed little and TBA values of the solid smoked product and liquid smoked one were lower than that of the others. Viable cell count was negative and texture changed little during storage. As for color difference during storage, green meat appeared on the surface of control and seasoned product after 15 days storage, while the masking of green meat could achieved by solid and liquid smoking treatment. And liquid smelling treatment was more effective than solid smoking. As a conclusion, retort pouched seasoned-oyster product treated with liquid smoke kept their good quality during 100 days storage and it seemed to be consumed as one of the instant foods which hold appropriate moisture contents and soft texture.

  • PDF

Three cases of Pulmonary Epithelioid Hemangioendothelioma (폐 유상피 혈관내피종 3예)

  • Lee, Seung-Hyun;Seo, Chang-Gyun;Park, Sun-Hyo;Kim, Kyung-Chan;Kim, Min-Soo;Han, Seung-Beom;Kwon, Kun-Young;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.1
    • /
    • pp.56-65
    • /
    • 2002
  • A pulmonary epithelioid hemangioendothelioma (PEH) is a rare tumor with a vascular origin. A PEH can arise in many organ systems, such as the lung, liver, bone and soft tissues. It is a borderline malignancy but the clinical course is usually benign. In this report, we describe three cases of PEH. Case 1, a 61-year-old man, had nonspecific chest discomfort and the chest X-ray showed a solitary lung nodule. This nodule was diagnosed by an open lung biopsy. The pathologic findings including abundant necrosis, mitosis and hyperchromatic and pleomorphic nuclei, indicated a malignancy. The electron microscopic study showed Weibel-Palade bodies and the immunohistochemical stain for CD31 showed a positive reaction in the tumor cells, and linear staining along the vascular lumina. Case 2, a 34-year-old man, was admitted for an evaluation of multiple small nodules, incidentally detected a screening chest X-ray. The nodules were diagnosed by a immunohistochemical stain for the factor VIII-related antigen. Case 3, a 34-year-old woman, complained of left pleuritic chest pain. A simple chest film and the chest CT scan revealed multiple bilateral nodules and a left pleural effusion. An immunohistochemical stain for the factor VIII-related antigen was used to diagnose the nodules. Forth-one months after the diagnosis, she died of pulmonary insufficiency.

Phase transformation and magnetic properties of $Ni_xFe_{100-x}$ thin films deposited by a co-sputtering (동시 스퍼터링법으로 제조된 $Ni_xFe_{100-x}$ 박막의 상변화와 자기적 특성)

  • Kang, Dae-Sik;Song, Jong-Han;Nam, Joong-Hee;Cho, Jeong-Ho;Chun, Myoung-Pyo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.6
    • /
    • pp.282-287
    • /
    • 2009
  • $Ni_xFe_{100-x}$ films with a thickness of about 100nm were deposited on Si(100) substrates at room temperature by a DC magnetron co-sputtering using Fe and Ni targets. Compositional, structural, electrical and magnetic properties of the films were investigated. $Ni_{67}Fe_{33}$, $Ni_{55}Fe_{45}$, $Ni_{50}Fe_{50}$, $Ni_{45}Fe_{55}$, $Ni_{40}Fe_{60}$ films are obtained by increasing the sputtering power of the Fe target. The films of x < 55 have BCC structure and show the phase transformation after annealing at the range of $300{\sim}450^{\circ}C$ for 2 h. On the other hand, the films of x < 50 have the mixed crystalline phases of BCC and FCC after the annealing treatment. The saturation magnetization was decreased initially by the phase transformation effect but then increased again after annealing at $450^{\circ}C$ due to the grain growth and crystallization of BCC phases.

Contact Transfer Printing Using Bi-layer Functionalized Nanobio Interface for Flexible Plasmonic Sensing

  • Lee, Jihye;Park, Jiyun;Lee, Junyoung;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.413-413
    • /
    • 2014
  • In this paper, we present a fabrication method of functionalized gold nanostructures on flexible substrate that can be implemented for plasmonic sensing application. For biomolecular sensing, many researchers exploit unconventional lithography method like nanoimprint lithography (NIP), contact transfer lithography, soft lithography, colloidal transfer printing due to its usability and easy to functionalization. In particular, nanoimprint and contact transfer lithography need to have anti-adhesion layer for distinctive metallic properties on the flexible substrates. However, when metallic thin film was deposited on the anti-adhesion layer coated substrates, we discover much aggravation of the mold by repetitive use. Thus it would be impossible to get a high quality of metal nanostructure on the transferred substrate for developing flexible electronics based transfer printing. Here we demonstrate a method for nano-pillar mold and transfer the controllable nanoparticle array on the flexible substrates without an anti-adhesion layer. Also functionalization of gold was investigated by the different length of thiol applied for effectively localized surface plasmonic resonance sensing. First, a focused ion beam (FIB) and ICP-RIE are used to fabricate the nanoscale pillar array. Then gold metal layer is deposited onto the patterned nanostructure. The metallic 130 nm and 250 nm nanodisk pattern are transferred onto flexible polymer substrate by bi-layer functionalized contact imprinting which can be tunable surface energy interfaces. Different thiol reagents such as Thioglycolic acid (98%), 3-Mercaptopropionic acid (99%), 11-Mercaptoundecanoic acid (95%) and 16-Mercaptohexadecanoic acid (90%) are used. Overcoming the repeatedly usage of the anti-adhesion layer mold which has less uniformity and not washable interface, contact printing method using bi-layer gold array are not only expedient access to fabrication but also have distinctive properties including anti-adhesion layer free, functionalized bottom of the gold nano disk, repeatedly replicate the pattern on the flexible substrate. As a result we demonstrate the feasibility of flexible plasmonic sensing interface and anticipate that the method can be extended to variable application including the portable bio sensor via mass production of stable nanostructure array and other nanophotonic application.

  • PDF