• Title/Summary/Keyword: soft breakdown

Search Result 28, Processing Time 0.024 seconds

A Study on the Auto Fuel Feeding Control System using Hall Sensor (홀 센서를 이용한 자동연료공급 제어장치에 관한 연구)

  • Kim, Gyu-Sung;Cho, Myung-Hyun
    • 전자공학회논문지 IE
    • /
    • v.43 no.3
    • /
    • pp.34-40
    • /
    • 2006
  • Usually, fluid or fuel supply device need space to need special sensor to control motor, attaches with ancillary equipment to attach sensor. Also, difficult point follows need signal line and other circuit etc. In this paper, used that proposed control system that use hall sensor to solve discomfort and problem and difference control principle of system happens in current flow according to motor action step. Also, could reduce breakdown by sensor establishment, reduce material costs and personnel expenses as well as control system superior. Auto-pumping system sees that will can apply, develop several kind of device that use system hereafter to all fluid supply systems through soft-ware adaptation.

Loss Analysis and Soft-Switching Behavior of Flyback-Forward High Gain DC/DC Converters with a GaN FET

  • Li, Yan;Zheng, Trillion Q.;Zhang, Yajing;Cui, Meiting;Han, Yang;Dou, Wei
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.84-92
    • /
    • 2016
  • Compared with Si MOSFETs, the GaN FET has many advantages in a wide band gap, high saturation drift velocity, high critical breakdown field, etc. This paper compares the electrical properties of GaN FETs and Si MOSFETs. The soft-switching condition and power loss analysis in a flyback-forward high gain DC/DC converter with a GaN FET is presented in detail. In addition, a comparison between GaN diodes and Si diodes is made. Finally, a 200W GaN FET based flyback-forward high gain DC/DC converter is established, and experimental results verify that the GaN FET is superior to the Si MOSFET in terms of switching characteristics and efficiency. They also show that the GaN diode is better than the Si diode when it comes to reverse recovery characteristics.

Gracilis Muscle Free Flap Transplantation Followed Up Over 10 Years (10년 이상 추시된 박 근 유리 판 이식술)

  • Yu, Chang Eun;Park, Ki Tae;Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.2
    • /
    • pp.108-112
    • /
    • 2011
  • Purpose: Gracilis muscle free flap transplantation is chosen in the medium sized soft tissue defect and bone exposure from trauma and chronic osteomyelitis in the lower extremity. We set a study to search for gracilis free flaps to know whether symptoms were cured or recurred in patients that have passed over 10 years from flap transplantation. Materials and Methods: From August 1995 through September 2010, we have performed 28 cases of gracilis muscle free flap in the lower extremities. Ever since no case visited to demand any discomfort, breakdown or recurrence in the flap site on outpatient basis. We made a telephone call to patients or relatives documented in the medical record and only 2 cases visited outpatient department and 9 cases postponed the visit who satisfied with the final result but 17 cases had wrong telephone numbers. Causes, area of lower extremity, recipient vessels in the lower extremity, condition of the donor thigh and overall satisfaction of the flap transplantation in activities of daily living were investigated and written down in the medical record. Results: 11 cases were reviewed after average postoperative 13.7 years. Gracilis muscle flaps were not break down at the recipient site in all cases. The wound of donor thigh wound healed good and overall activities of daily living was satisfied in all cases. Conclusion: Gracilis muscle flaps which had performed and followed up average 13.7 years revealed confident in the medium sized soft tissue defect and bone exposure from trauma and chronic osteomyelitis in the lower extremity.

  • PDF

A study on the fabrication and its electrical characteristics of the schottky diodes on the laser anneled poly-si substrate (레이저 열처리된 다결정 실리콘 기판을 이용한 소트키 다이오드의 제작 및 그 전기적 특성에 관한 연구)

  • Kim, Jae-Yeong;Kang, Moon-Sang;Koo, Yong-Seo;An, Chul
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.106-111
    • /
    • 1996
  • Schottky diodes are fabricated on laser annealed and unannealed polysilicon substrate and their electrical characteristics are studied and analyzed. Current of laser annealed devices are larger than that of unannealed devices because of grain growth, decrease of grain boundary and trap density, lowering of grain boundary barrier height, decrease of dopant segregation. At low forward bias (<0.7V), currents of unanealed devices are larger. Soft breakdown voltages of laser annealed devices are larger than that of unannealed devices.

  • PDF

The Sinus Tarsi Approach for the Treatment of Intra-Articular Calcaneal Fractures (족근동 접근법을 이용한 관절 내 종골 골절의 치료)

  • Sato, Toru;Shiota, Naofumi;Tetsunaga, Tomonori;Kim, Bom Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.257-263
    • /
    • 2013
  • Open reduction and internal fixation is currently considered as a gold standard of treatment in most of the intra-articular calcaneal fractures. Among various different approaches, extensile lateral approach is the most popular since it provides good exposure to the subtalar joint. However, wide skin incision followed by extensive soft tissue dissection leading to increased risk of wound breakdown is the most serious drawback. Sinus tarsi approach, a minimal invasive technique to approach the subtalar joint and reduce the intra-articular calcaneal fractures, provides good clinical outcome and less wound complications compared to the extensile lateral approach. This article introduces the surgical technique and review of the literature regarding the sinus tarsi approach.

Clinical Experience of Pyoderma Gangrenosum with Extensive Soft Tissue Necrosis (광범위 연조직 괴사를 동반한 괴저농피증의 치험례)

  • Lim, Sung Yoon;Park, Dong Ha;Pae, Nam Suk;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.615-618
    • /
    • 2008
  • Purpose: Pyoderma gangrenosum is a rare cutaneous ulcerative disease. First described in 1930, the condition is characterized by progressive ulceration with deeply undermined purple-red edge. The lower extremities are most commonly affected but other parts of the skin and mucous membranes may also be involved. Although medical treatments with topical wound therapy are commonly used, surgical intervention is still controversial. In this paper, we report an atypical case of pyoderma gangrenosum which was characterized by extensive soft tissue breakdown. Methods: A 27-year-old male patient was referred to our institution with a $7{\times}8cm$ sized deeply undermined ulceration with pus-like discharge and fever. Incision and drainage was performed at another clinic 3 days prior to admission to our institution. After a thorough physical examination and the MRI review, a diagnosis of necrotizing faciitis was made. Accordingly, fasciotomy and debridement was performed. However, the wound enlarged progressively and the patient remained highly febrile for 9 days after the treatment. Septic screening did not reveal any occult infection. After a secondary review of the case, the initial diagnosis of necrotizing fasciitis was rejected and changed to pyoderma gangrenosum. With the use of dexamethasone intravenously, the wound improved dramatically and the fever was eliminated. Steroid mediation was tapered with duration of 1 month. The wound was stabilized and subsequently covered with split-thickness skin graft. Results: Split-thickness skin grafting with 1 : 1.5 mesh was successfully taken. Conclusion: Initial clinical features of pyoderma gangrenosum are very similar to that of necrotizing fasciitis. High fever and progressive ulceration with severe pain could invite earlier surgical approach. The advancing wound margins (the well defined violaceous, undermined border and necrotic ulcer base) and lack of isolation of pathogenic organism was used to make the correct diagnosis of pyoderma gangrenosum. We achieved a good result with proper medication and split-thickness skin graft.

Review on Advanced Health Monitoring Methods for Aero Gas Turbines using Model Based Methods and Artificial Intelligent Methods

  • Kong, Changduk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.123-137
    • /
    • 2014
  • The aviation gas turbine is composed of many expensive and highly precise parts and operated in high pressure and temperature gas. When breakdown or performance deterioration occurs due to the hostile environment and component degradation, it severely influences the aircraft operation. Recently to minimize this problem the third generation of predictive maintenance known as condition based maintenance has been developed. This method not only monitors the engine condition and diagnoses the engine faults but also gives proper maintenance advice. Therefore it can maximize the availability and minimize the maintenance cost. The advanced gas turbine health monitoring method is classified into model based diagnosis (such as observers, parity equations, parameter estimation and Gas Path Analysis (GPA)) and soft computing diagnosis (such as expert system, fuzzy logic, Neural Networks (NNs) and Genetic Algorithms (GA)). The overview shows an introduction, advantages, and disadvantages of each advanced engine health monitoring method. In addition, some practical gas turbine health monitoring application examples using the GPA methods and the artificial intelligent methods including fuzzy logic, NNs and GA developed by the author are presented.

A Stator Fault Diagnosis of an Induction Motor based on the Phase Angle of Park's Vector Approach (Park's Vector Approach의 위상각 변이를 활용한 유도전동기 고정자 고장진단)

  • Go, Young-Jin;Lee, Buhm;Song, Myung-Hyun;Kim, Kyoung-Min
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.4
    • /
    • pp.408-413
    • /
    • 2014
  • In this paper, we propose a fault diagnosis method based on Park's Vector Approach using the Euler's theorem. If we interpreted it as Euler's theorem, it is possible to easily find the phase angle difference between the healthy condition and the fault condition. And, we analyzed the variation of the phase angle and performed the diagnostic method of the induction motor using feature vectors that were obtained by using a Fourier transform. The analysis of time and speed variation of the motor was performed and, as a result, we could find more soft variations than rough variations. In particular, the analysis of the distortion through each phase shows that two-turn and four-turn shorted motors are linearly separable. In this experiment, we know that the maximum breakdown threshold value for determining steady-state fault detection is 49.0788. Simulation and experimental results show the more detectable than conventional method.

The Reconstruction of Foot using Medial Plantar Flap (내측 족저 피판을 이용한 족부의 재건)

  • Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.2
    • /
    • pp.153-161
    • /
    • 2002
  • Purpose : Plantar surfaces, calcaneal area, and region of Achilles insertion, which are extremely related with weight-bearing area and shoes application, must be reconstructed with glabrous and strong fibrous skin. Numerous methods of reconstructing defects of these regions have been advocated, but the transfer of similar local tissue as a cutaneous flap with preservation of sensory potential would best serve the functional needs of the weight-bearing and non-weight-bearing surfaces of this region. Therefore it is recommended to use the limited skin of medial surface of foot that is similar to plantar region and non-weight-bearing area. In this paper we performed the medial plantar flap transfered as a fasciocutaneous island as one alterative for moderate-sized defects of the plantar forefoot, plantar heel, and area around the ankle in 25 cases and report the result, availability and problem of medial plantar flap. Materials and methods : We performed proximally based medial plantar flap in 22 cases and reverse flow island flap in 3 cases. Average age was $36.5(4{\sim}70)$ years and female was 3 cases. The causes of soft tissue defect were crushing injury on foot 4 cases, small bony exposure at lower leg 1 case, posterior heel defect with exposure of calcaneus 8 cases, severe sore at heel 2 cases, skin necrosis after trauma on posterior foot 4 cases, and defect on insertion area of Achilles tendon 6cases. Average follow up duration was 1.8(7 months-9.5 years) years. Results: Medial plantar flaps was successful in 22 patients. 18 patients preserved cutaneous branches of medial plantar nerve had sensation on transfered flap but diminished sensation or dysesthesia. At the follow up, we found there were no skin ulceration, recurrence of defect or skin breakdown in all 18 patients. But there was one case which occurred skin ulceration postoperatively among another 4 cases not contained medial plantar nerve. At the last follow up, all patients complained diminished sensation and paresthesia at medial plantar area distally to donor site, expecially with 4 patients having severe pain and discomfort during long-time walking. Conclusion : Medial plantar island flap based on medial plantar neurovascualr pedicle have low failure rate with strong fibrous skin and preserve sensibility of flap, so that it is useful method to reconstruct the skin and soft tissue defect of foot. But it should be emphasized that there are some complications such like pain and paresthesia by neuropraxia or injury of medial plantar nerve at more distal area than donor site. We may consider that medial plantar flap have limited flap size and small arc of rotation, and require skin graft closure of the donor defect and must chose this flap deliberately.

  • PDF

Occurrence of bi-flagellated protists in the tunics of ascidians Halocynthia roretzi with tunic-softness syndrome collected from Tongyeong, south coast of Korea (통영산 물렁증 멍게 피막의 편모충 감염)

  • Shin, Yun-Kyung;Kim, Hyoun-Joong;Park, Kyung-Il;Choi, Min-Soon;Jun, Je-Cheon;Kim, Eung-Oh
    • Journal of fish pathology
    • /
    • v.24 no.3
    • /
    • pp.197-204
    • /
    • 2011
  • The edible ascidian Halocynthia roretzi is a commercially important fisheries resource in Korea. However, for the last several years, outbreaks of mass mortalities of the species have been occurring along the south and east coasts of Korea, where most ascidians are produced. Although it is known that tunic-softness syndrome is associated with these mortality events, the agent causing the syndrome has not yet been confirmed. To determine the agent causing tunic-softness syndrome, healthy and diseased ascidians were collected in March 2011 from Tongyeong, on the south coast of Korea, and were used for biological and pathological investigations. The results showed that diseased ascidians exhibited remarkably reduced body fluid, fatness index, and tunic index compared with healthy specimens. Interestingly, bi-flagellated protozoans were observed specifically in the tissue imprints and tunic cultures of diseased ascidians at an occurrence rate of 97.5%. Histological observation showed that the thickness of the tunics of diseased ascidians was reduced by half, and irregular structure and breakdown of the tunic fiber bundles were observed. In particular, flagellate-like cells were observed in the diseased ascidians. Our study clearly shows that bi-flagellated protists are present only in the softened ascidians, suggesting that the flagellates are partly or entirely associated with soft-tunic syndrome. Accordingly, further investigations to verify the effects of the flagellates found in the present study on soft-tunic syndrome should be conducted.