• Title/Summary/Keyword: smooth

Search Result 6,576, Processing Time 0.046 seconds

Effects of The Substrate Temperature and The Thin film Thickness on The Properties of The Ga-doped ZnO Thin Film (기판온도 및 박막두께가 Ga-doped ZnO 박막의 특성에 미치는 영향)

  • Cho, Won-Jun;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.6-13
    • /
    • 2010
  • In this study, Ga-doped ZnO (GZO) thin films have been fabricated on Eagle 2000 glass substrates at various substrate temperatures $100{\sim}400^{\circ}C$ and thin film thickness by RF magnetron sputtering in order to investigate the structural, electrical, and optical properties of the GZO thin films. It is observed that all the thin films exhibit c-axis orientation and a (002) diffraction peak only. The GZO thin films, which were deposited at $T=300^{\circ}C$ and 400 nm, shows the highest (002) orientation, and the full width at half maximum (FWHM) of the (002) diffraction peak is $0.4^{\circ}$. AFM analysis shows that the formation of relatively smooth thin films are obtained. The lowest resistivity ($8.01{\times}10^{-4}\;{\Omega}cm$) and the highest carrier concentration ($3.59{\times}10^{20}\;cm^{-3}$) are obtained in the GZO thin films deposited at $T=300^{\circ}C$ and 400 nm. The optical transmittance in the visible region is approximately 80 %, regardless of process conditions. The optical band-gap shows the slight blue-shift with increase in doping which can be explained by the Burstein-Moss effect.

Optical and Electrical Properties of Al-doped ZnO Thin Films Fabricated by Sol-gel Method with Various Al Doping Concentrations and Annealing Temperatures (Sol-gel 법으로 제작한 Al-doped ZnO 박막의 도핑 농도 및 열처리 온도에 따른 광학적 및 전기적 특성)

  • Shin, Hyun-Ho;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.5
    • /
    • pp.1-7
    • /
    • 2007
  • AZO thin films have been fabricated on quartz substrate with various Al doping concentrations and annealing temperatures by sol-gel method. The bset condition of (002) orientation and smooth surface (rms = 1.082 nm) is obtained for the AZO thin film doped with 1 mol % Al and annealed at 550 $^{\circ}C$. The optical transmittance of AZO thin films is higher than 80 % in the visible region. We observe that the energy band gap extends with increasing the Al doping concentration. This phenomenon is due to the Burstein-Moss effect. Through the measurement of Hall effect, it is observed that the AZO thin film has larger carrier concentration and smaller electrical resistivity than the pure ZnO thin film. However, the AZO thin film shows the decrease of carrier concentration and the increase of resistivity with the increase of Al concentration, that is due to the segregation of Al at grain boundaries. The maximum carrier concentration of $1.80{\times}10^{19}\;cm^{-3}$ and the minimum resistivity of 0.84 ${\Omega}cm$ are obtained for the AZO thin film doped with 1 mol % Al and annealed at 550 $^{\circ}C$.

Evaluation of Effect of Rock Joints on Seismic Response of Tunnels (터널의 지진응답에 대한 암반 절리의 영향 평가)

  • Yoo, Jin-Kwon;Chang, Jaehoon;Park, Du-Hee;Sagong, Myung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.9
    • /
    • pp.41-55
    • /
    • 2014
  • In performing seismic analysis of tunnels, it is a common practice to ignore the rock joints and to assume that the rock mass surrounding the tunnel is continuous. The applicability of this assumption has not yet been validated in detail. This study performs a series of pseudo-static discrete element analyses to evaluate the effect of rock joint on the seismic response of tunnels. The parameters considered are joint intersection location, joint spacing, joint stiffness, joint dip, and interface stiffness. The results show that the joint stiffness has the most critical influence on the tunnel response. The tunnel response increases with the spacing, resulting in localized concentration of moment and shear stress. The response of the tunnel is the lowest for joints dipping at $45^{\circ}$. This is because large shear stresses result in rotation of the principal planes by $45^{\circ}$. In summary, the weathered and smooth, vertical or horizontal, and widely spaced joint set will significantly increase the tunnel response under seismic loading. The tunnel linings are shown to be most susceptible to damage due to induced shear stress, and therefore should be checked in the seismic design.

A Model Curriculum Development for Clinical Nurse Specialist Training Program in Organ Transplant (장기이식 전문간호사를 위한 교육과정 연구)

  • Kim, Jung-Soon
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.6 no.2
    • /
    • pp.171-185
    • /
    • 2000
  • The twenty-first century may be said to be entering into a specialized qualification age to meet the needs of new technical innovations such as environmental changes, demographical changes, changes in the constitution of diseases, changes in the needs of the national health, reforms of information and knowledge, etc., which requires the provision of competitive services that can fulfill the high level needs of consumers. In consequence, it is needed to apply a practical nursing model that can serve as a guide for healthy society and to secure the sphere that can affect nursing policy-making by keeping pace with the changing environment. Furthermore, it is also urgent to expand more the activity sphere of nurse specialists with authority and autonomy, establish their legal foundation, establish a qualification accreditation system for nurse specialists, and develop educational programs. In Korea, the law relative to organ transplant past the national assembly on February 9, 2000, legally acknowledged brain death, which indicated to us the emergence of an age of organ transplant. Therefore, it necessitates to find out those of brain death from whom organ transplant is feasible in clinical practices, with their families' consent link to those terminal organ failure patients who are in need of an organ, and mediate both parties so that smooth transplant can be accomplished. A series of these complicated procedures require systematically trained specialists with high level techniques of organic management. With this in mind, this study was conducted on 69 clinical nurse specialists for organ transplant, accredited by the hospital, who are in active service in clinical practices. The resultant findings were revealed, as follows: 1. The qualifications of clinical nurse specialists for organ transplant should be accredited by Ministry of Health and Welfare or Korea Nurses Association. 2. The validity of qualifications should be for three years, and their renewal should be based on marks of a supplemental training or an education course for more than 12 hours a year. 3. The qualification of the clinical nurse specialist necessitates theoretical lectures and practices on those nurses who have had clinical experience in the pertinent field. 4. The course of training is required to be one year in the length of training and take more than 20 credits (320 hours) and 5 credits (240 hours).

  • PDF

The Modelling and Machining of Leisure Boat Plug using CAD/CAM System (CAD/CAM 시스템을 이용한 레저보트의 플러그 모델링 및 가공)

  • Kim, Seong-Il
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.259-272
    • /
    • 2008
  • In order to improve the productivity and quality of boat's mold in leisure boat industry, the development of modelling and machining technology of leisure boat's plug is strongly required. The traditional lines drawing approach by hand required the designer to both create fair curves and to make sure that the curves matched up to each other in the three main drawing views: profile, plan, and section. However, one will find when studying lines drawings in books that the curves might look smooth and fair, but the lines do not agree exactly in the three views. Therefore, the 2 dimensional drawing data of leisure boat are transformed using 3 dimensional design s/w and CAM s/w. In addition, the leisure boat is designed with a 3 dimensional s/w. The NC cutting data are generated by the CAM s/w. The surface characteristics of machined surface are investigated at various cutting conditions such as spindle speed, feed speed, and cutting material.

Real-Time Hierarchical Techniques for Rendering of Translucent Materials and Screen-Space Interpolation (반투명 재질의 렌더링과 화면 보간을 위한 실시간 계층화 알고리즘)

  • Ki, Hyun-Woo;Oh, Kyoung-Su
    • Journal of Korea Game Society
    • /
    • v.7 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • In the natural world, most materials such as skin, marble and cloth are translucent. Their appearance is smooth and soft compared with metals or mirrors. In this paper, we propose a new GPU based hierarchical rendering technique for translucent materials, based on the dipole diffusion approximation, at interactive rates. Information of incident light, position, normal, and irradiance, on the surfaces are stored into 2D textures by rendering from a primary light view. Huge numbers of pixel photons are clustered into quad-tree image pyramids. Each pixel, we select clusters (sets of photons), and then we approximate multiple subsurface scattering term with the clusters. We also introduce a novel hierarchical screen-space interpolation technique by exploiting spatial coherence with early-z culling on the GPU. We also build image pyramids of the screen using mipmap and pixel shader. Each pixel of the pyramids is stores position, normal and spatial similarity of children pixels. If a pixel's the similarity is high, we render the pixel and interpolate the pixel to multiple pixels. Result images show that our method can interactively render deformable translucent objects by approximating hundreds of thousand photons with only hundreds clusters without any preprocessing. We use an image-space approach for entire process on the GPU, thus our method is less dependent to scene complexity.

  • PDF

Effect of GABA on the Contractility of Small Intestine Isolated from Rat (흰쥐 적출 소장의 수축성에 미치는 GABA의 영향)

  • Huh, Joon-Young;Kwon, Oh-Cheol;Ha, Jeong-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.95-105
    • /
    • 1991
  • This study was designed to investigate the effect of GABA and related substances on the spontaneous contraction of rat small intestine. The rats(Sprague-Dawley), weighing 200-250g, were sacrificed by cervical dislocation, and the small intestine was isolated. Longitudinal muscle strips from duodenum, jejunum and ileum were suspended in Biancani's isolated muscle chambers and myographied isometrically. GABA and muscimol, a GABA A receptor agonist relaxed the duodenum and jejunum significantly, but baclofen-induced relaxation in those muscle strips was negligible. The effectiveness of GABA and muscimol in various regions were the greatest on duodenum, and greater on jejunum than on ileum The effect of GABA and muscimol was antagonized by bicuculline, a compeptitive GABA A receptor antagonist and picrotoxin, a noncomptitive GABA A receptor antagonist. Duodenal relaxation induced by GABA and muscimol was unaffected by hexamethonium, but was prevented by tetrodotoxin. These results suggest that GABA inhibit the contractility of smooth muscle with distinct regional difference of efficacy, and the site of inhibitory action is the GABA A receptor existing at the presynaptic membrane of postganglionic excitatory nerves.

  • PDF

Teratoma Formation in Immunocompetent Mice After Syngeneic and Allogeneic Implantation of Germline Capable Mouse Embryonic Stem Cells

  • Aldahmash, Abdullah;Atteya, Muhammad;Elsafadi, Mona;Al-Nbaheen, May;Al-Mubarak, Husain Adel;Vishnubalaji, Radhakrishnan;Al-Roalle, Ali;Al-Harbi, Suzan;Manikandan, Muthurangan;Matthaei, Klaus Ingo;Mahmood, Amer
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5705-5711
    • /
    • 2013
  • Background: Embryonic stem cells (ESCs) have the potential to form teratomas when implanted into immunodeficient mice, but data in immunocompetent mice are limited. We therefore investigated teratoma formation after implantation of three different mouse ESC (mESC) lines into immunocompetent mice. Materials and Methods: BALB/c mice were injected with three highly germline competent mESCs (129Sv, BALB/c and C57BL/6) subcutaneously or under the kidney capsule. After 4 weeks, mice were euthanized and examined histologically for teratoma development. The incidence, size and composition of teratomas were compared using Pearson Chi-square, t-test for dependent variables, one-way analysis of variance and the nonparametric Kruskal-Wallis analysis of variance and median test. Results: Teratomas developed from all three cell lines. The incidence of formation was significantly higher under the kidney capsule compared to subcutaneous site and occurred in both allogeneic and syngeneic mice. Overall, the size of teratoma was largest with the 129Sv cell line and under the kidney capsule. Diverse embryonic stem cell-derived tissues, belonging to the three embryonic germ layers, were encountered, reflecting the pluripotency of embryonic stem cells. Most commonly represented tissues were nervous tissue, keratinizing stratified squamous epithelium (ectoderm), smooth muscle, striated muscle, cartilage, bone (mesoderm), and glandular tissue in the form of gut- and respiratory-like epithelia (endoderm). Conclusions: ESCs can form teratomas in immunocompetent mice and, therefore, removal of undifferentiated ESC is a pre-requisite for a safe use of ESC in cell-based therapies. In addition the genetic relationship of the origin of the cell lines to the ability to transplant plays a major role.

Development of a Chameleonic Pin-Art Equipment for Generating Realistic Solid Shapes (실감 입체 형상 생성을 위한 카멜레온형 핀아트 장치 개발)

  • Kwon, Ohung;Kim, Jinyoung;Lee, Sulhee;Kim, Juhea;Lee, Sang-won;Cho, Jayang;Kim, Hyungtae
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.497-506
    • /
    • 2020
  • A chameleonic surface proposed in this study was a pin-art and 3D display device for generating arbitrary shapes. A smooth and continuous surface was formed using slim telescopic actuators and high-elasticity composite material. Realistic 3D shapes were continuously generated by projecting dynamic mapping images on the surface. A slim telescopic actuator was designed to show long strokes and minimize area for staking. A 3D shape was formed by thrusting and extruding the high-elasticity material using multiple telescopic actuators. This structure was advantageous for generating arbitrary continuous surface, projecting dynamic images and lightening weight. Because of real-time synchronization, a distributed controller based on EtherCAT was applied to operate hundreds of telescopic actuators smoothly. Integrated operating software consecutively generated realistic scenes by coordinating extruded shapes and projecting 3D image from multiple projectors. An opera content was optimized for the chameleon surface and showed to an audience in an actual concert.

Lack of Influence of the ACE1 Gene I/D Polymorphism on the Formation and Growth of Benign Uterine Leiomyoma in Turkish Patients

  • Gultekin, Guldal Inal;Yilmaz, Seda Gulec;Kahraman, Ozlem Timirci;Atasoy, Hande;Dalan, A. Burak;Attar, Rukset;Buyukoren, Ahmet;Ucunoglu, Nazli;Isbir, Turgay
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1123-1127
    • /
    • 2015
  • Uterine leiomyomas (ULM), are benign tumors of the smooth muscle cells of the myometrium. They represent a common health problem and are estimated to be present in 30-70% of clinically reproductive women. Abnormal angiogenesis and vascular-related growth factors have been suggested to be associated with ULM growth. The angiotensin-I converting enzyme (ACE) is related with several tumors. The aim of this study was to identify possible correlation between ULM and the ACE I/D polymorphism, to evaluate whether the ACE I/D polymorphism could be a marker for early diagnosis and prognosis. ACE I/D was amplified with specific primer sets recognizing genomic DNA from ULM (n=72) and control (n=83) volunteers and amplicons were separated on agarose gels. The observed genotype frequencies were in agreement with Hardy-Weinberg equilibrium ($x^2=2.162$, p=0.339). There was no association between allele frequencies and study groups ($x^2=0.623$; p=0.430 for ACE I allele, $x^2=0.995$; p=0.339 for ACE D allele). In addition, there were no significant differences between ACE I/D polymorphism genotype frequencies and ULM range in size and number ($X^2=1.760;$ p=0.415 for fibroid size, $X^2=0.342;$ p=0.843 for fibroid number). We conclude that the ACE gene I/D polymorphism is not related with the size or number of ULM fibroids in Turkish women. Thus it cannot be regarded as an early diagnostic parameter nor as a risk estimate for ULM predisposition.