• Title/Summary/Keyword: smart meter

Search Result 165, Processing Time 0.036 seconds

A Real-Time Demand Response Management Using Smart Box (스마트 박스를 활용한 실시간 수요관리)

  • Ko, Dong-Kwan;Bea, Jun-Cheol;Min, Kyoung-Chon;Lee, Jae-Kyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • The Demand Response Market is a nation-wide power and energy management program of electric power demand response operated by KPX (Korea Power eXchange). Therefore, any savings could be determined by KEPCO's AMR(Automatic Meter Reading) data. However, the customers and the service providers participating in the market could not know the real time value due to the 15 minute or even more delayed AMR data communicated. Here, a new concept of a smart box has been introduced and demonstrated to provide the real time saving values compared to the current KEPCO's AMR data approach.

A study on the practical use of smart meter end-user demand data (스마트미터 데이터 활용 방법에 대한 연구)

  • Park, Geunyeong;Jung, Donghwi;Jun, Sanghoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.10
    • /
    • pp.759-768
    • /
    • 2021
  • This work introduces a new approach that classifies individual household water usage by examining the characteristics of smart meter end-user demand data. Here, one of the most well-known unsupervised machine learning, K-means algorithm, is applied to classify water consumptions by each household. The intensity and duration of end-user demands are used as main features to determine the households with similar water consumption pattern. The results showed that 21 households are classified into 13 clusters with each cluster having one, two, three, or five houses. The reasoning why multiple households are classified into the same cluster is described in this paper with respect to the collected data and end-user water consumption behavior.

Design of Advanced Metering Infrastructure Network Based on Multi-Channel Cluster (다중채널 클러스터 기반의 AMI 네트워크 설계)

  • Choi, Seok-Jun;Shim, Byoung-Sup;Chae, Soo-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.3
    • /
    • pp.207-215
    • /
    • 2013
  • This paper is channel assignment and scheduling techniques for efficient wireless AMI network. In AMI system, the multi-channel cluster network to be proposed defines the communication channel between NC (Network Coordinator) and CDA (Clustered Data Aggregator) as the network channel. CDA and OMD(Out Meter display) and communication channel between SMD(Smart Meter Device) are defined as the group channel. AMI network of the multi-channel cluster based in which the network channel and group channel is mixed increases the administration efficiency through the physical/logical consumer channel clustering. The reliability of inspection data through the channel use distinguished between the adjacent cluster is enhanced. In addition, the fast aggregation of data is possible and the size of a metering network is increased through the channel allocation of the multichannel cluster based.

Development of Smart Tendon Instrumented with Optical FBG Sensors (FBG 센서를 내장한 스마트 강연선 개발)

  • Kim, Jae-Min;Kim, Young-Sang;Kim, Hyoun-Wo;Seo, Dong-Nam;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper reports an attempt to develop 7-wire steel tendon which is instrumented with optical FBG sensors. The tendon is devised to replace the king cable, which is located in the center of the tendon, by a steel tube in which the FBG sensor are attached along the hole using a high-mobility polyester resin. The circular steel tube has typical of 5 mm outer diameter and 1 mm inner diameter, and can easily be manufactured by means of an pultrusion process. Using the tube, in this study, three different types of one meter-long smart tendons are fabricated depending on mixture ratio of polyester resin and initiator. The performance of the FBG sensors as well as mechanical characteristics of the prototype are tested through the tensile test. Test results shows that the proposed smart tendon is in principle very effective for measuring the working strain of the tendon.

  • PDF

Information and Communication Technologies for Smart Water Grid Applications

  • Ballhysa, Nobel;Choi, Gyewoon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.218-226
    • /
    • 2019
  • The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.

The Analysis of Conductive fibers for Smart Wear (스마트웨어 적용을 위한 전도성 소재분석)

  • Park, Yeong-Min;Jin, Sang-U;Jo, Gwang-Nyeon;Kim, Hong-Je;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.10a
    • /
    • pp.31-32
    • /
    • 2008
  • In this study, we have investigated a conductive fiber properties for smart wear. The effect of factors such as fiber length, denier, sewing method, washing on conductivity achieved was investigated and determined using stereoscopic microscope, SEM and LCR meter.

  • PDF

A Study on the development of big data-based AI water meter freeze and burst risk information service (빅데이터 기반 인공지능 동파위험 정보서비스 개발을 위한 연구)

  • Lee, Jinuk;Kim, Sunghoon;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.3
    • /
    • pp.42-51
    • /
    • 2023
  • Freeze and burst water meter in winter causes many social costs, such as meter replacement cost, inability of water use, and secondary damage by freezing water. The government is making efforts to modernize local waterworks, and in particular, is promoting SWM(Smart Water Management) project nationwide. In this study suggests a new freeze risk notification information service based on the temperature by IoT sensor inside the water meter box rather than outside temperature. In addition, in order to overcome the quantitative and regional limitation of IoT temperature sensors installed nationwide, and AI based temperature prediction model was developed that predicts the temperature inside water meter boxes based on data acquired from IoT temperature sensors and other information. Through the prediction model optimization process, a nationwide water meter freezing risk information service was convinced.

A Diagnosis Method of Communication Networks for AMI Smart Meters (AMI 시스템 구축용 스마트 미터의 통신 상태 진단방법)

  • Jung, Joonhong;Choi, Gilyong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.55-56
    • /
    • 2015
  • A smart meter is a kind of electronic meters that measures and records consumption of electric energy in intervals of an hour or less and transmits that information to the remote places. AMI provides two-way communication path between utilities and consumers and should be able to support smart grid's new functionalities such as demand-response actions and real time pricing. The main objective of this paper is to provide a new diagnosis method and system for testing of smart meters in AMI neighborhood area network.

  • PDF

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Cortex M3 Based Lightweight Security Protocol for Authentication and Encrypt Communication between Smart Meters and Data Concentrate Unit (스마트미터와 데이터 집중 장치간 인증 및 암호화 통신을 위한 Cortex M3 기반 경량 보안 프로토콜)

  • Shin, Dong-Myung;Ko, Sang-Jun
    • Journal of Software Assessment and Valuation
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • The existing smart grid device authentication system is concentrated on DCU, meter reading FEP and MDMS, and the authentication system for smart meters is not established. Although some cryptographic chips have been developed at present, it is difficult to complete the PKI authentication scheme because it is at the low level of simple encryption. Unlike existing power grids, smart grids are based on open two-way communication, increasing the risk of accidents as information security vulnerabilities increase. However, PKI is difficult to apply to smart meters, and there is a possibility of accidents such as system shutdown by sending manipulated packets and sending false information to the operating system. Issuing an existing PKI certificate to smart meters with high hardware constraints makes authentication and certificate renewal difficult, so an ultra-lightweight password authentication protocol that can operate even on the poor performance of smart meters (such as non-IP networks, processors, memory, and storage space) was designed and implemented. As a result of the experiment, lightweight cryptographic authentication protocol was able to be executed quickly in the Cortex-M3 environment, and it is expected that it will help to prepare a more secure authentication system in the smart grid industry.