• 제목/요약/키워드: small-scale cable

검색결과 22건 처리시간 0.032초

멀티케이블을 이용한 초전도 전력케이블의 구성에 관한 연구 (A Study on the Composition of Superconducting Power Cable Using the Multi-cable)

  • 최석진;이상진;심기덕;조전욱;이수길;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.42-46
    • /
    • 2010
  • The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. The superconducting tapes of transmission layers and shield layer are wound in a cylindrical shape with a winding pitch. The radius of cylinder and the number of superconducting tapes are decided considering to the transmission current capacity and the critical current of superconducting tapes. The increasement of transmission current capacity will increase in volume of HTS cable system. In this paper, the composition method of supercondcuting power cable using the multi-cable is presented. The coated conductor tape can be wound on the smaller cylinder because it has the smaller critical bending diameter than the BSCCO tape. A small-scale cable was composed using the coated conductor tapes and a multi-cable is composed using a small-scale cable considering to transmission current capacity. Even increase of transmission current capacity, this method has advantage that the HTS superconducting power cable can be composed easily. The 22.9 kV and 154 kV superconducting power cable was composed using the presented method.

Nb_{3}$Sn 초전도 CICC의 sub-cable to sub-cable 접합 및 접합저항 측정 (Measurement of electrical resistance at the Nb_{3}$Sn CICC joint fabricated by sub-cable to sub-cable joining)

  • 이호진;홍계원;김기백;권선칠;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.89-92
    • /
    • 1999
  • A small scale joint sample of Nb3Sn CICC was fabricated by sub-cable to sub-cable joining. This joint was produced by parallel insertion of one end of each sub-cable into the sub-cable space of the other side of cable, which can decrease the equivalent electrical resistance at the joint is expected to have average properties, dc resistance and ac losses, in view of the shapes of ITER type joint and strand to strand joint. The 3.8nOhm of dc resistance was measured in the range of 10-200A transport current. The normalized resistivity of the joint was about 6.7 $\mu}$Ohm-$^mm{2}$. Considering the normalized resistivity, the full scale joint prepared by sub-cable to sub-cable joining may have similar joint dc resistance with other conventional full scale joints with a shorter joining length.

  • PDF

Numerical Simulation of Electro-Mechanical Impedance Response in Cable-Anchor Connection Interlace

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권1호
    • /
    • pp.11-23
    • /
    • 2011
  • In this study, a finite element(FE) analysis on electro-mechanical impedance response of cable-anchor connection interface under various anchor force is presented. In order to achieve the objective, the following approaches are implemented. Firstly, an interface washer coupled with piezoelectric(PZT) material is designed for monitoring cable-force loss. The interface washer is a small aluminum plate on which a PZT patch is surface-bonded. Cable-force loss could be monitored by installing the interface washer between the anchor plate and the anchorage of cable-anchor connection and examining the changes of impedance of the interface washer. Secondly, a FE model for cable-anchor connection is established to examine the effect of cable-force on impedance response of interface washer. Also, the effects of geometrical and material properties of the interface washer on impedance responses under various cable-forces are investigated. Finally, validation of the FE analysis is experimentally evaluated by a lab-scale cable-anchor connection.

재긴장과 무선 모니터링이 가능한 유압식 케이블 접합부시스템의 실험에 대한 연구 (Experimental study of Hydraulic Cable Connection Systems with Re-tensioning and Wireless Monitoring)

  • 김민수;이기학;김성범;이성민;백기열
    • 한국공간구조학회논문집
    • /
    • 제11권2호
    • /
    • pp.71-79
    • /
    • 2011
  • 케이블 구조시스템의 경우 자기 평형 상태를 유지하기 때문에 장력이 손실된 특정 케이블을 재긴장을 하지 않으면 구조엔지니어가 요구한 하중보다 더 큰 하중이 다른 케이블에 전달되어 손상을 야기 할 수 있다. 또한, 턴버클을 이용한 재긴장 방법이 기존에 널리 적용되고 있지만 정확한 장력조절과 대구경 케이블에는 적절하지 못하고 인장재의 하중의 크기를 측정하는 것이 어렵다. 따라서 효과적으로 재긴장 할 수 있는 유압식 볼팅 접합부를 개발하고 인장력을 실시간으로 확인할 수 있는 모니터링 시스템을 적용하였다. 본 논문에서는 개발된 시스템의 현장 적용성 실험과 결과를 제시하였다.

Damping and frequency of twin-cables with a cross-link and a viscous damper

  • Zhou, H.J.;Yang, X.;Peng, Y.R.;Zhou, R.;Sun, L.M.;Xing, F.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.669-682
    • /
    • 2019
  • Vibration mitigation of cables or hangers is one of the crucial problems for cable supported bridges. Previous research focused on the behaviors of cable with dampers or crossties, which could help engineering community apply these mitigation devices more efficiently. However, less studies are available for hybrid applied cross-ties and dampers, especially lack of both analytical and experimental verifications. This paper studied damping and frequency of two parallel identical cables with a connection cross-tie and an attached damper. The characteristic equation of system was derived based on transfer matrix method. The complex characteristic equation was numerically solved to find the solutions. Effects of non-dimensional spring stiffness and location on the maximum cable damping, the corresponding optimum damper constant and the corresponding frequency of lower vibration mode were further addressed. System with twin small-scale cables with a cross-link and a viscous damper were tested. The damping and frequency from the test were very close to the analytical ones. The two branches of solutions: in-phase modes and the out-of-phase modes, were identified; and the two branches of solutions were different for damping and frequency behaviors.

Particle filter approach for extracting the non-linear aerodynamic damping of a cable-stayed bridge subjected to crosswind action

  • Aljaboobi Mohammed;Shi-Xiong Zheng;Al-Sebaeai Maged
    • Wind and Structures
    • /
    • 제38권2호
    • /
    • pp.119-128
    • /
    • 2024
  • The aerodynamic damping is an essential factor that can considerably affect the dynamic response of the cable-stayed bridge induced by crosswind load. However, developing an accurate and efficient aerodynamic damping model is crucial for evaluating the crosswind load-induced response on cable-stayed bridges. Therefore, this study proposes a new method for identifying aerodynamic damping of the bridge structures under crosswind load using an extended Kalman filter (EKF) and the particle filter (PF) algorithm. The EKF algorithm is introduced to capture the aerodynamic damping ratio. PF technique is used to select the optimal spectral representation of the noise. The effectiveness and accuracy of the proposed solution were investigated through full-scale vibration measurement data of the crosswind-induced on the bridge's girder. The results show that the proposed solution can generate an efficient and robust estimation. The errors between the target and extracted values are around 0.01mm and 0.003^o, respectively, for the vertical and torsional motion. The relationship between the amplitude and the aerodynamic damping ratio is linear for small reduced wind velocity and nonlinear with the increasing value of the reduced wind velocity. Finally, the results show the influence of the level of noise.

Cable-tensioning에 의한 SCST 구조의 형상 형성과 거동 특성 (Shaping Formation and Behaviour Characteristic for SCST Structure by Cable-tensioning)

  • 김진우;권민호
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.819-825
    • /
    • 2008
  • 이 논문은 케이블텐션을 이용해서 SCST 구조의 형상 형성과 시공에 대해 연구한 논문인데, 이 공법은 균일한 모양의 피라미드로 만들어진 공간구조를 신속하고 경제적으로 시공할 수 있는 공법이 될 수 있다. 초기의 배치에 있어서 상현재와 웨브부재는 일정한 길이이나 하현재는 원하는 최종적인 형상에 비례해서 갭이 주어져 있다. 본 연구에서 제안된 형상 형성법의 적용성과 신뢰성은 축소된 모델과 실물 크기의 실험 모델에 대한 비선형 유한요소 해석과 실험적인 조사를 통해 확인할 수 있다. 연구의 결과, MERO 조인트의 거동 특성은 공간 구조의 형상 해석에서 매우 중요하며 본 논문은 실무에서 형상을 예측할 수 있는 가장 적합한 모델링 기법을 제시하고 있다. 그리고 실제 설계에 필요한 형상 실험의 거동 특성을 보여 주고 있다.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

농업용 트랙터 기반 소형 타워야더의 견인 성능 개선에 관한 연구 (Traction Performance Improvement Study on a Small-scale Tower Yarder Attached to a Farm Tractor)

  • 백승호;최윤성;조민재;문호성;한상균;김대현;오재헌
    • 한국산림과학회지
    • /
    • 제108권4호
    • /
    • pp.562-573
    • /
    • 2019
  • 국내 임목수확작업에 사용되고 있는 트랙터 기반 소형 타워야더는 소경재 생산을 목적으로 개발되었으며, 중대경재 수확 체제로 변화함에 따라 견인 성능의 개선이 필요하다. 이 연구는 동력 전달방식을 기존의 기계식에서 기계 유압식으로 개선하여 타워야더의 최대 견인력을 비교·분석하였으며, 트랙터 엔진속도, 유압식 동력 전달 기구의 압력을 변수로 두고 견인 성능 실험을 실시하였다. 실험 수준은 트랙터 엔진속도(1,200, 1,400, 1,600, 1,800, 2,000, 2,200 rpm) 6수준, 동력 전달 기구의 압력(4.9, 6.9, 8.8 MPa) 3수준으로 선정하였다. 기존의 경우 최대 견인력은 엔진 회전속도 757 rpm에서 15,146.6 N의 최대견인력을 발휘하였으나 개선된 타워야더는 엔진 회전속도 1,575 rpm에서 36,140 N의 최대 견인력이 나타나, 최대 견인력이 2.4배 증가되었다. 이에 따라 중대경재 위주의 목재수확 현장에서 작업이 가능할 것으로 판단된다. 또한 기존 장비를 재활용하여 성능 개선함으로써 견인력이 큰 집재장비의 신규 도입 및 운영에 필요한 비용을 줄일 수 있을 것으로 기대된다.

Distributed crack sensors featuring unique memory capability for post-earthquake condition assessment of RC structures

  • Chen, Genda;McDaniel, Ryan;Sun, Shishuang;Pommerenke, David;Drewniak, James
    • Smart Structures and Systems
    • /
    • 제1권2호
    • /
    • pp.141-158
    • /
    • 2005
  • A new design of distributed crack sensors based on the topological change of transmission line cables is presented for the condition assessment of reinforced concrete (RC) structures during and immediately after an earthquake event. This study is primarily focused on the performance of cable sensors under dynamic loading, particularly a feature that allows for some "memory" of the crack history of an RC member. This feature enables the post-earthquake condition assessment of structural members such as RC columns, in which the earthquake-induced cracks are closed immediately after an earthquake event due to gravity loads, and are visually undetectable. Factors affecting the onset of the feature were investigated experimentally with small-scale RC beams under cyclic loading. Test results indicated that both crack width and the number of loading cycles were instrumental in the onset of the memory feature of cable sensors. Practical issues related to dynamic acquisition with the sensors are discussed. The sensors were proven to be fatigue resistant from shake table tests of RC columns. The sensors continued to show useful performance after the columns can no longer support additional loads.