소수력발전용 용적형수차의 성능해석과 최적설계법에 관한 연구 (Performance Analysis and Optimum Design Method of Positive Displacement Turbine for Small Hydropower)

  • 최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.514-521
    • /
    • 2007
  • There has been considerable interest recently in the topic of renewable energy. This is primarily due to concerns about environmental impacts. Moreover, fluctuating and rising oil prices, increases in demand, supply uncertainties and other factors have led to increased calls for alternative energy sources. Small hydropower, especially using water supply system, attracts high attentions because of relatively lower cost and smaller space requirements to construct the plant. Moreover. newly developed positive displacement turbine has high acceptability for the system. Therefore, the purpose of this study is focused on the examination of the performance characteristics and proposition of a optimum design method of the turbine for the improvement of the performance. The results show that newly proposed optimum design method for the turbine has high accuracy of performance prediction and good applicability for the performance improvement of the turbine.

논산지역 마을상수도 수질의 수리지화학 및 통계 분석 (Hydrogeochemistry and Statistical Analysis of Water Quality for Small Potable Water Supply System in Nonsan Area)

  • 고경석;안주성;석희준;이진수;김형수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권6호
    • /
    • pp.72-84
    • /
    • 2008
  • 본 연구는 논산지역 마을상수도를 대상으로 수질 모니터링, 수리지화학적 고찰 및 다변량 통계분석을 통하여 수질에 관한 문제점과 원인을 규명하고 타당한 관리 방안을 마련하고자 수행되었다. 논산지역은 마을상수도 이용이 많은 전형적인 농촌지역으로 지질은 화강암이 가장 넓은 면적을 차지하며 옥천대 변성퇴적암, 편마암과 화산암이 분포한다. 마을상수도의 수질 모니터링 결과 전국 평균인 2.5%보다 5-8배 높은 13-21% 정도가 수질기준을 초과하였으며 주요 오염성분은 질산성질소, 탁도, 총대장균, 일반세균, 불소 및 비소로 조사되었다. 연구지역 남쪽과 북쪽에서 높게 나타나는 질산성질소 오염의 주요 원인으로서 비닐하우스 같은 시설영농의 영향이 가장 큰 것으로 나타났다. 마을상수도 수질은 Ca와 $HCO_3$가 지배적이나 화강암 지역에서는 농경지와 주거지 등의 인위적인 오염의 영향으로 Na, Cl 및 $NO_3$가 증가되었다. 주성분분석 결과 주로 농경과 인위적 오염의 영향을 나타내는 주성분 2에 의하여 크게 두 개의 그룹인 화강암과 편마암 및 옥천대 지하수로 구분된다. 판별분석은 초기 지질분류와 판별분석 예측결과의 오차가 5.56%로서 주성분분석보다 더 명확하게 각 지질별 지하수 특징을 보여준다. 다변량 통계분석은 수리지화학적 특성의 종합적 분석을 가능하게 하여 지질특성에 의한 지하수 수질의 변화를 명확하게 구분할 수 있는 방법으로 사료되었다. 논산시 마을상수도 수질에 대한 연구결과는 지질에 의해 영향받는 토지이용, 토양 특성 및 지형 등이 복합적으로 작용하여 지하수 수리지화학적 특성을 결정하는 것임을 확인하였다. 따라서 향후 정부 및 지자체의 마을상수도관리는 지질, 토지이용, 지형 및 토양 특성 등에 대한 종합적 자료 구축 및 해석이 필요하다.

프로판-이소부탄 혼합냉매를 적용한 소형 냉동시스템의 성능 특성에 관한 연구 (Performance Characteristics of Propane/isobutane Mixtures in a Small Refrigeration System)

  • 윤원재;김용찬
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.73-82
    • /
    • 2002
  • A small refrigeration system used in a water purifier was tested by employing propane/isobutane (R-290/R-6OOa) mixtures as an alternative refrigerant of R-12. The drop-in tests were performed by varying mass fraction of propane at 0.25, 0.5 and 0.75 with a change of both refrigerant charge amount and capillary tube length in order to find an optimum composition in aspect of performance and reliability of the system. As a result, the mixture of 50% propane-50% isobutane showed the best performance and reliability among them in a small refrigeration system. During steady state operations, both the COP and refrigeration capacity increased by 4% and 9%, respectively, as compared to the baseline R-12 system. In addition, the propane/isobutane (50/50) mixture system yielded advantages in the minimization of modification and redesigning of system components due to very similar saturation tempera- ture and pressure characteristics with R-12.

다중수원 수처리 의사결정에 관한 실험적 연구 (An experimental study on decision making for multi-source water)

  • 정정우;조형락;이상호;채수권
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2015
  • A combined treatment system using multiple source water is becoming important as an alternative to conventional water supply for small-scale water systems. In this research, combined water treatment systems were investigated for simultaneous use of multi-source water including rainwater, ground water, river water, and reclaimed wastewater. A laboratory-scale system was developed to systematically compare various combinations of water treatment processes, including sand filtration, microfiltration (MF), granular activated carbon (GAC), and nanofiltration (NF). Results showed that the efficiency of combined water treatment systems was affected by the quality of feed waters. In addition, a simply approach based on the concept of linear combination was suggested to support a decision-making for the optimum water treatment systems with the consideration of final water quality.

소규모 댐의 운영기준 및 기법 연구 (A Study of Operation Standard and Method of Small Dams)

  • 김필식;김선주;이주용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.260-265
    • /
    • 2005
  • The purpose of this study is to established a storage management method and operation standard for irrigation dams occupying the largest portion of small dams using storage management system. The system can be applied to seongju dam for effective management. The storage management method was established considering hydrology simulation and statistical analysis using the system. This method and operation standard are capable of analyzing additional available water, considering the water demand and supply of basin actually. It can improve the flood control capacity and water utilization efficiency by the flexible operation of storage space.

  • PDF

2중 단동비닐하우스의 태양열 축열이용 효과 (Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse)

  • 이성현;유영선;문종필;윤남규;권진경;이수장;김경원
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Second Law Optimization of Water-to-Water Heat Pump System

  • Kim, Kyu-Hyung;Woo, Joung-Son;Lee, Se-Kyoun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.122-128
    • /
    • 2003
  • This paper presents a thermodynamic analysis of heat pump system using water as a heat source and heat sink. The primary object in this study is the optimization of exergetic efficiency. Two different systems, 2-stream and 1-stream system, are analyzed in detail. Mass flow ratio (the ratio of mass flow rate of water through evaporator to that through condenser) is identified as the most important parameter to be optimized. It is shown that there exists an optimum mass flow ratio to maximize exergetic efficiency. The variation of optimum exergetic efficiency of 2-stream system is quite small and the value lies between 0.2∼0.23 for the range of investigation in this study. However, far better performance can be obtained from 1-stream system. This means considerable irreversibilities are generated through condenser of the 2-stream system. The effects of adiabatic efficiency of compressor-motor unit on the overall system performance are also examined in the analysis.

상수도 관망 유량관측 자료의 주성분 분석을 위한 분석기간의 설정 (Identifying an Appropriate Analysis Duration for the Principal Component Analysis of Water Pipe Flow Data)

  • 박수완;전대훈;정소연;김주환;이두진
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.351-361
    • /
    • 2013
  • In this study the Principal Component Analysis (PCA) was applied to flow data in a water distribution pipe system to analyze the relevance between the flow observation dates, which have the outliers of observed night flows, and the maintenance records. The data was obtained from four small size water distribution blocks to which 13 maintenance records such as pipe leak and water meter leak belong. The flow data during four months were used for the analysis. The analysis was carried out to identify an appropriate analysis period for a PCA model for a water distribution block. To facilitate the analyses a computational algorithm was developed. MATLAB was utilized to realize the algorithm as a computer program. As a result, an appropriate PCA period for each of the case study small size water distribution blocks was identified.

구미하수처리장 방류구에서의 소수력발전 설치 및 운영에 관한 연구 (Feasibility Study on the Construction of Small Hydro-Power Plants in Gumi Sewage Treatment Plant Discharge Point)

  • 나동훈;이승환
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.173-181
    • /
    • 2010
  • This study was conducted to investigate the possible installation of small hydro-power plant at the discharge point of Gumi sewage treatment plant (STP) using treated wastewater. Sufficient amount of water to transfer to electric power and the selection of proper location are two essential elements for the construction of small hydro-power facility. Preliminary analysis based on site visit and existing data in Gumi STP were made. Capacity of the small hydro-power plants and exact location were determined by geomorphological condition and flow duration characteristics. Flow duration characteristics and its duration curve were identified using monthly rainfall data in Gumi STP. Relevant facts of small hydro-power system in other STP were referred to adopt to Gumi STP situation. Flowrate of treated effluents and effective head between flow chamber and the location of hydraulic turbine in Gumi STP are found to be $3.70m^3$/sec and 3.5m respectively. Electric generation rate based on this feasibility study was estimated to be 86.3kW/h. Yearly electric generation rate was expected to be 932.4MMh. Proposed small hydro-power plant construction in Gumi STP is to be reasonable.

소규모 고도 수처리 기술 -가정용 정수시스템 중심으로-

  • 성경학;조봉연;박호완
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.207-231
    • /
    • 1997
  • The use household water purifier is continuously increasing due to the distrust of the piped, rap water, which may be caused by the deterioration of water quality and water supply facilities in Korea. The water purifier distributing in the domestic market is the membrane type that composes of membrane as a basic filter, sediment filter as a prefilter and activated carbon filter instead of one purifying water system. The membrane type using as a water cleaning system is mainly the method of micro filtration(NIF) as well as ultra filtration(UF) and reverse osmosis(RO). The types of MF and UF are using to remove suspended solids and virus, and RO is using to remove ionic compound in chemical organic compounds. At the beginning the household water purifier was imported as end-product or assembled by only importing module from small businesses in Korea. Therefore, people was hard to confide in the product quality because the sales policy and management of water purifier by small business were not effectively organized. However, the defects of water purifier having up to now ate improving by the efforts of special branches of water purifier and large enterprises, and new great products are developing and producing. To develop the best quality product of water purifier in Korea, it should be considered seasonal water characteristrics rather than any other condition. For example, the water purifier can be affected by the water temperature change, increase of suspended solids in the rainy season and inflow of raw water having concentration in a dry season. The subject we have to investigate in the future is to develop the water purifying system adaptable in Korea which can treat the water quality using close analyses of local and seasonal water characteristics.