• Title/Summary/Keyword: small water system

Search Result 1,317, Processing Time 0.03 seconds

A Study on Economics of Air Stripping Towers and Activated Carbon Adsorption(Multicomponent System) (충전탑 공기 스트리핑과 활성탄 흡착의 경제성에 관한 연구(다중성분계))

  • Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.33-42
    • /
    • 1998
  • The optimum design and preliminary cost estimations of air stripping towers ASTs with granular activated carbon adsorption (GAC) systems as the off-gas treatment were done and compared to liquid-phase GAC system. The optimum design and preliminary cost estimations were done for either single or multicomponent systems. A computer program was developed for this study. 15 single compounds and their multicomponent systems were studies. Even with off-gas treatment, AST was generally a less expensive process for treatment of volatile organics than liquid-phase GAC system. Treatment costs of small systems were sensitive to system capacity. Accumulative effect of treatment costs was found in multicomponent systems. The cost of a multicomponent system was highly dependent on the least strippable component in ASTs even with gas-phase GAC or the least adsorbable component in liquid-phase GAC system.

  • PDF

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (I) - Energy Efficiency Comparison for Working Fluids of R245fa and Water - (선박용 디젤엔진의 배기가스 열회수 시스템 (I) - R245fa 및 Water 의 작동유체에 대한 에너지효율 비교 -)

  • Choi, Byung-Chul;Kim, Young-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.293-299
    • /
    • 2012
  • The thermodynamic efficiency characteristics of R245fa and water as working fluids have been analyzed for the electricity generation system applying the Rankine cycle to recover the waste heat of the exhaust gas from a diesel engine for the propulsion of a large ship. The theoretical calculation results showed that the cycle, system, and total efficiencies were improved as the turbine inlet pressure was increased for R245fa at a fixed mass flow rate. In addition, the net work rate generated by the Rankine cycle was elevated with increasing turbine inlet pressure. In the case of water, however, the maximum system efficiencies were demonstrated at relatively small ratios of mass flow rate and turbine inlet pressure, respectively, compared to those of R245fa. The optimized values of the net power of the cycle, system efficiency, and total efficiency for water had relatively large values compared to those of R245fa.

A study on the Thermal Design of the Compact Type Small Fresh Water Generator (콤팩트형 소형 담수화장치의 열설계에 관한 연구)

  • 김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • In Korea accelerated industry development and urbanization during the last three decades have led serious water pollution problems in many parts of the nation. Especially in the regions of west and south coast have low fresh water in the dry season of spring and summer. In the place isolated from land it is important to secure the fresh water for drinking and general service. This study is concerned on the thermal system design to develop low-pressure evaporation type fresh water gen-erator of capacity 1 ton/day using the heat source of non-operating boiler in the season of spring and summer. The results obtained from this study are as follows. the water quantitieds generated from experi-mental evaporator showed good coincidence with the calculated values. The maximum production quantity was 1.38ton/day at pressure 40mmHg abs. and temperature $80^{\circ}C$.

  • PDF

Test of Heat Recovery Performance of a Microturbine (마이크로터빈의 열회수 성능시험)

  • Jeon, Mu-Sung;Lee, Jong-Jun;Kim, Tong-Seop;Chang, Se-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

Development of flood forecasting system on city·mountains·small river area in Korea and assessment of forecast accuracy (전국 도시·산지·소하천 돌발홍수예측 시스템 개발 및 정확도 평가)

  • Hwang, Seokhwan;Yoon, Jungsoo;Kang, Narae;Lee, Dong-Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.3
    • /
    • pp.225-236
    • /
    • 2020
  • It is not easy to provide sufficient lead time for flood forecast in urban and small mountain basins using on-ground rain gauges, because the time concentration in those basins is too short. In urban and small mountain basins with a short lag-time between precipitation and following flood events, it is more important to secure forecast lead times by predicting rainfall amounts. The Han River Flood Control Office (HRFCO) in South Korea produces short-term rainfall forecasts using the Mcgill Algorithm for Precipitation-nowcast by Lagrangian Extrapolation (MAPLE) algorithm that converts radar reflectance of rainfall events. The Flash Flood Research Center (FFRC) in the Korea Institute of Civil Engineering and Building Technology (KICT) installed a flash flood forecasting system using the short-term rainfall forecast data produced by the HRFCO and has provided flash flood information in a local lvel with 1-hour lead time since 2019. In this study, we addressed the flash flood forecasting system based on the radar rainfall and the assessed the accuracy of the forecasting system for the recorded flood events occurred in 2019. A total of 31 flood disaster cases were used to evaluate the accuracy and the forecast accuracy was 90.3% based on the probability of detection.

Evaluation of Flow Characteristics of Mud Treatment System for Onshore Drilling (육상시추용 Mud treatment system의 유동특성 평가)

  • Kim, Seung-Chan;Chun, Joong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.763-772
    • /
    • 2021
  • Drilling Mud Treatment Systems are widely used for Oil Gas drilling mud circulation, horizontal directional drilling mud recycling, geothermal drilling, mining, coal exploration drilling, water well drilling. Degasser is a device used in drilling to remove gasses from drilling fluid which could otherwise form bubbles. For small amounts of entrained gas in a drilling fluid, the degasser can play a major role of removing small bubbles that a liquid film has enveloped and entrapped. As with the desander, its purpose is to remove unwanted solids from the mud system. The smaller cones allow the desilter to efficiently remove smaller diameter drill solids. In this study, a simulation study is conducted on the degasser of the facility in the Mud Treatment System to conduct a performance review on the gas separation in the mud.

A Development of Real-time Flood Forecasting System for U-City (Ubiquitous 환경의 U-City 홍수예측시스템 개발)

  • Kim, Hyung-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.181-184
    • /
    • 2007
  • Up to now, a lot of houses, roads and other urban facilities have been damaged by natural disasters such as flash floods and landslides. It is reported that the size and frequency of disasters are growing greatly due to global warming. In order to mitigate such disaster, flood forecasting and alerting systems have been developed for the Han river, Geum river, Nak-dong river and Young-san river. These systems, however, do not help small municipal departments cope with the threat of flood. In this study, a real-time urban flood forecasting service (U-FFS) is developed for ubiquitous computing city which includes small river basins. A test bed is deployed at Tan-cheon in Gyeonggido to verify U-FFS. Wireless sensors such as rainfall gauge and water lever gauge are installed to develop hydrologic forecasting model and CCTV camera systems are also incorporated to capture high definition images of river basins. U-FFS is based on the ANFIS (Adaptive Neuro-Fuzzy Inference System) that is data-driven model and is characterized by its accuracy and adaptability. It is found that U-FFS can forecast the water level of outlet of river basin and provide real-time data through internet during heavy rain. It is revealed that U-FFS can predict the water level of 30 minutes and 1 hour later very accurately. Unlike other hydrologic forecasting model, this newly developed U-FFS has advantages such as its applicability and feasibility. Furthermore, it is expected that U-FFS presented in this study can be applied to ubiquitous computing city (U-City) and/or other cities which have suffered from flood damage for a long time.

  • PDF

Fundamental Study for Ocean Wave Energy Converter Using a Rack-Pinion Gear Based One-way Mechanism (일방향 기구 기반 랙-피니언 기어를 이용한 병진형 파력발전장치에 대한 기초연구)

  • Lee, Junkyoung;Cho, Sungil;Lee, Sehan;Lee, Sangchun;No, Hyunchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.167.1-167.1
    • /
    • 2011
  • Sustainable energy generation is becoming extremely imperative due to the expected limitations in current energy resources and to reduce pollution. Especially, because of its considerable energy potential, ocean wave energy has been investigated with regard to power generation. To develop large high power wave generator system, it is important to make a small scale proto type and to test that. Thus the objective of this research is to examine the characteristics of a mechanically excited generator system having small power capacity experimentally. The water reservoir (4 m length, 1.5 m width and 1.8 m depth) having a wave maker to make arbitrary height and period of the water wave was made. The proto type consists of three main parts; a buoy, rack-pinion base one-way mechanism, and a wave generator(Fig.1). The water wave is going up and down and the hexahedron buoy is following the wave. The rack gear attached to the buoy is also going up and down to roll the pinion connected to an electric generator then it produces electricity. The experiments were performed with several conditions of water waves, and the power outputs over 30 W could be measured for some conditions. In future works, to achieve higher performance for the proto type, the effects of primary parameters (buoy shape and mass, etc.) on the system efficiency will be identified.

  • PDF

Circuit Capacity of Water Cooling on Domestic Small Diesel Engine (소형(小型)디젤 기관(機關)의 냉각수(冷却水) 순환량(循環量)에 대(對)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.91-96
    • /
    • 1992
  • Diesel engine being used on power tiller has over heating problem while running at the rated power range, The reason for overheating the engine is mainly owing to so small capacity of cooling system. This study was conducted to determine relatively optimum capacity of cooling system for the diesel engine. The results obtained are summarized as follows. 1. The capacity of cooling system for the diesel engine being used in the rural area was not sufficient to cool the engine at the rated power. 2. It is desirable that the cooling water flow rate was $12{\ell}/min$ if we used supplementary pump for increasing the cooling efficiency. 3. As cooling water was circuited $12{\ell}/min$, highest temperature of cooling water was $91^{\circ}C$. This value is within $88^{\circ}C{\pm}5^{\circ}C$ of SAE Standard criterion.

  • PDF