• Title/Summary/Keyword: small motion

Search Result 1,403, Processing Time 0.042 seconds

A Study on the Distance Error Correction of Maritime Object Detection System (해상물체탐지시스템 거리오차 보정에 관한 연구)

  • Byung-Sun Kang;Chang-Hyun Jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.139-146
    • /
    • 2023
  • Maritime object detection systems, which detects small maritime obstacles such as fish farm buoys and visualizes distance and direction, is equipped with a 3-axis gimbal to compensate for errors caused by hull motion, but there is a limit to distance error corrections necessitated by the vertical movement of the camera and the maritime object due to wave motions. Therefore, in this study, the distance error of maritime object detection systems caused by the movement of the water surface according to the external environment is analyzed and corrected using average filter and moving average filter. Random numbers following a Gaussian standard normal distribution were added to or subtracted from the image coordinates to reproduce the rise or fall of the buoy under irregular waves. The distance calculated according to the change of image coordinates, the predicted distance through the average filter and the moving average filter, and the actual distance measured by laser distance meter were compared. In phases 1 and 2, the error rate increased to a maximum of 98.5% due to the changes of image coordinates due to irregular waves, but the error rate decreased to 16.3% with the moving average filter. This error correction capability was better than with the average filter, but there was a limit due to failure to respond to the distance change. Therefore, it is considered that use of the moving average filter to correct the distance error of the maritime object detection system will enhance responses to the real-time distance change and greatly improve the error rate.

The Effects of Weekly Reports as a Method for Encouraging Student Questions in Middle School Science Instruction (중학교 과학 수업에서 학생 질문을 촉진하는 방안으로서의 주단위 보고서의 효과)

  • Kang, Hun-Sik;Lee, Sung-Mi;Kwon, Eun-Kyung;Noh, Tae-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.3
    • /
    • pp.385-392
    • /
    • 2006
  • This study investigated the effects of weekly reports as a method for encouraging student questions in middle school science instruction by focusing on student conceptual understanding, achievement, concept map, and perceptions of weekly reports. Seventh graders (N=211) from a middle school were assigned to control and weekly reports (WR) groups. All students were taught about the 'three states of matter', the 'motion of molecules', and the 'change of states and thermal energy' for eighteen class hours. Students in the WR group were required to write weekly reports for six of those periods. Results revealed that conception test scores for the WR group were significantly higher than those for the control group. Compared conception test scores by learning strategy, students using a surface learning strategy in the WR group scored significantly higher than those in the control group. While students employing a deep learning strategy in the WR group also performed better than those in the control group, the difference was relatively small. The scores of an achievement test and a concept map test for the WR group were significantly higher than those for the control group. However, there were no significant interactions between instruction and students' learning strategy in the two variables. It was also found that most students in the WR group positively perceived weekly reports.

Analysis of Research Trends on the Korean Medicine Treatments of Subacromial-Subdeltoid Bursitis (견봉하-삼각근하 점액낭염의 한의치료에 대한 국내외 연구동향 분석)

  • Hyunsuk Park;Dong-Jin Jang;Jonghyun Lee;Sungjae Yoo;Minji Sun;Junsoo Kim;Yongjun Kim;Jeong-Hee Noh;Si-Hyoung Kim;Jung-Min Yun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.34 no.2
    • /
    • pp.85-100
    • /
    • 2024
  • Objectives This study aims to analyze clinical studies on subacromial-subdeltoid (SA-SD) bursitis and propose future directions for clinical research on SA-SD bursitis. Methods We searched eight databases to investigate research trends in Korean medicine treatments for SA-SD bursitis up to November 2023. A total of thirty-one studies were included in this analysis. Results Among the included studies, there were six case reports from Korea, fifteen case reports, and ten randomized controlled trials from abroad. Various interventions were uesd, including acupuncture, pharmacopuncture, manual therapy, electro-acupuncture, cupping, physiotherapy, acupotomy, warm-acupuncture, herbal medicine, and moxibustion. The evaluation tools used in these studies included the total effective rate, visual analogue scale, range of motion, and numeral rating scale. Conclusions This study provides an overview of the research trends in Korean medicine treatments for SA-SD bursitis. However, given the low quality and small sample sizes of the studies, the evidence supporting effect of Korean medicine treatments for SA-SD bursitis was insufficient. Further clinical trials and systematic reviews are required.

A Study of the Relationship Between Number of Ground Motions and Parameters of Seismic Fragility Curve (지진취약도 곡선 생성시 선택된 지진파 수에 따른 입력변수 변화에 관한 연구)

  • Park, Sangki;Park, Ki-Tae;Kim, Jaehwan;Jung, Kyu-San;Seo, Dong-Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.5
    • /
    • pp.285-294
    • /
    • 2024
  • Seismic fragility curves present the conditional probability of damage to target structures due to external seismic load and are widely used in various ways. When constructing such a seismic fragility curve, it is essential to consider various types and numbers of ground motions. In general, the earthquake occurrence characteristics of an area where the target structure of the seismic fragility curve exists are analyzed, and based on this, appropriate ground motions are selected to derive the seismic fragility curve. If the number of selected ground motions is large, the diversity of ground motions is considered, but a large amount of computational time is required. Conversely, if the number of ground motions is too small, the diversity of ground motions cannot be considered, which may distort the seismic fragility curve. Therefore, this study analyzed the relationship between the number of ground motions considered when deriving the seismic fragility curve and the parameters of the seismic fragility curve. Using two example structures, numerical analysis was performed by selecting a random number of ground motions from a total of two hundred, and a seismic fragility curve was derived based on the results. Analysis of the relationship of the parameter of the seismic fragility curve and the number of selected ground motions was performed. As the number of ground motions considered increases, uncertainty in ground motion selection decreases, and when deriving seismic fragility curves considering the same number of ground motions, uncertainty increases relatively as the degree of freedom of the target structure increases. However, considering a relatively large number of ground motions, uncertainty appeared insignificant regardless of increased degrees of freedom. Finally, it is possible that the increase in the number of ground motions could lower the epistemic uncertainty and thus improve the reliability of the results.

Clinical Significance of Creatine Kinase MB mass and Cardiac Troponin I as a Marker of Perioperative Myocardial Infarction After Coronary Artery Bypass Grafting (관상동맥 우회술 후 심근경색의 표지자로서 Creatine Kinase MB 농도와 Cardiac Troponon I의 임상적 의의)

  • 이재진;김응중;이원용;신윤철;지현근
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2002
  • Background: A perioperative myocardial infarction(PMI) is one of the major complications after CABG. Among diagnostic methods of PMI, CK-MB activity assays have been increasingly replaced by CK-MB mass assays, which have more sensitive, simple measurement. Also, new cardiac-specific and -sensitive marker, cardiac troponin I(cTnl), has been shown to be a marker of myocardial infarction. We report our evaluation of clinical significance of CK-MB mass and cTnl as a marker of PMI after CABG. Material and Method: We studied 32 patients who underwent CABG at Kangdong Sacred Hospital between April 2000 and April 2001. Postoperative serum CK-MB activity level, serum CK-MB mass, cTnl, electrocardiogram, echocardiogram, and clinical data were recorded prospectively The diagnosis of PMI was defined as positive 2 among 3 or all of the following , by a new Q wave on the electrocardiogram, by serum CK-MB activity higher than 200 lU/L within 72 hours after operation, and by new regional wall motion abnormality on the echocardiogram. Result: After CABG, 3 patients had sustained a PMI according to current diagnostic criteria. As serum CK-MB activity time course, a level of CK-MB activity 12 hours after CABG had very linear correlated significance with serum CK-MB mass 24hours(R=0.946) and cTnl 48 hours(R=0.933) after CABG(p=0.000). As we used a receiver operating characteristics curve(ROC curve) for a diagnostic cutoff value in patients with PMI, serum CK-MB mass levels higher than 30.05 ug/L 24 hours after CABG detected the presence of PMI with an area under the ROC curve of 1.0, a sensitivity of 100%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 100%. Also serum cTnl levels higher than 17.15 ug/L 48 hours after CABG detected the presence of PMI with an area under the ROC curve of 0.98, a sensitivity of 100%, a specificity of 96.6%, a positive preclictive value of 75%, and a negative predictive value of 100% Conclusion: We concluded that both the measurement of CK-MB mass and cTnl are the easier, accurate methods as a diagnostic marker of PMT after CABG, also as a proposal of diagnostic cutoff value enables to an early detection of PMI. However, a 1arger number of patient will be needed because of statistic limitation that a small number of participating patients, a small number of PMI.

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF