• Title/Summary/Keyword: small displacement sensor

Search Result 75, Processing Time 0.021 seconds

Modal Analysis of Wind Turbine Blade Using Optical-Fiber Bragg-Grating Sensors (광섬유 브레그격자 센서를 이용한 풍력발전기 날개의 모드 해석)

  • Kim, Chang-Hwan;Paek, In-Su;Yoo, Neung-Soo;Nam, Yoon-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.513-516
    • /
    • 2011
  • The dynamic behavior of a small wind-turbine blade was analyzed experimentally. Arrays of fiber Bragg-Grating (FBG) sensors attached along the blade were used to measure the strains of the blade surface. An impact test was performed to estimate the resonance frequencies of the fundamental and higher modes of the cantilever blade system developed for this study. The results were similar to the results for conventional strain gages. However, FBG sensors could sense modes that strain gauges could not sense. The strains obtained from the FBG sensor array were used to estimate displacement-mode shapes of the blade.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Proposal of a piezoelectric floating mass transducer for implantable middle ear hearing devices (이식형 인공중이를 위한 압전 플로팅 매스 트랜스듀서의 제안)

  • Lee, Chang-Woo;Kim, Min-Kyu;Park, Il-Yong;Song, Byung-Seop;Roh, Yong-Rae;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.322-330
    • /
    • 2005
  • A new type of transducer, piezoelectric floating mass transducer (PFMT) which has advantages of piezoelectric and electromagnetic transducer has been proposed and implemented for the implantable middle ear hearing devices. By the uneven bonding of piezoelectric material to the inner bottom of transducer case, the PFMT can vibrate back-and-forth along the longitudinal axis of the transducer even though the piezoelectric material within the cylindrical case produces only the bilateral expansion and contraction according to the applied electrical signal. To improve efficiency of the PFMT, the multi-layered piezoelectric material has been adapted. The small number of components in the PFMT enables the simple manufacturing and the easy implanting into the middle ear. In order to examine the characteristics of vibration, mechanical modeling and finite element analyses of the proposed transducer have been performed. From the result of theoretical analyses and the measured data from the experiment, it is verified that the implemented PFMT can be used in implantable middle ear hearing devices.

Evaluation of Thermal Movements of a Cable-Stayed Bridge Using Temperatures and Displacements Data (온도와 변위 데이터를 이용한 사장교의 온도신축거동 평가)

  • Park, Jong Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.779-789
    • /
    • 2015
  • Because cable-supported bridges have long spans and large members, their movements and geometrical changes by temperatures tend to be bigger than those of small or medium-sized bridges. Therefore, it is important for maintenance engineers to monitor and assess the effect of temperature on the cable-supported bridges. To evaluate how much the superstructure expands or contracts when subjected to changes in temperature is the first step for the maintenance. Thermal movements of a cable-stayed bridge in service are evaluated by using long-term temperatures and displacements data. Displacements data are obtained from extensometers and newly installed GNSS (Global Navigation Satellite System) receivers on the bridge. Based on the statistical data such as air temperatures, each sensor's temperatures, average temperatures and effective temperatures, correlation analysis between temperatures and displacements has been performed. Average temperatures or effective temperatures are most suitable for the evaluation of thermal movements. From linear regression analysis between effective temperatures and displacements, the variation rate's of displacement to temperature have been calculated. From additional regression analysis between expansion length's and variation rate's of displacement to temperature, the thermal expansion coefficient and neutral point have been estimated. Comparing these parameters with theoretical and analytical results, a practical procedure for evaluating the real thermal behaviors of the cable-supported bridges is proposed.

3-D Analysis of Slope by Tension Wire Sensing (Tension Wire 계측을 통한 비탈면의 3차원 거동 분석)

  • Shin, Taeju;Kim, Taesoo;Hwang, Sanggoo;Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2015
  • Several sensor systems are used to estimate and predict the slope behaviors, however though slope sensing systems are much up-to-dated compared to before, they are mainly focused on the hardware developing. It means the analyzing software is deficient to apply the examining slope behavior for slope stability. In real case, slope behavior shows the 3-dimensional movement and failure; however the modeling methods for 3-D behavior are more difficult and need more variables. 1-D analysis shows only the length variation, however the real slope makes the 3-D behaviors. To fix the 3-D space coordinate, three values should be determined such as length, horizontal angle and vertical angle. Therefore if the 3-D coordinate system were composed by the points considered of two directions and length, the 3-D space could be separated into horizontal plane and vertical plane. The data from DY-slope in Chungbuk province was analyzed to the developed 3-D coordinate system. It is concluded from the results of 3-D analysis, the slope is generally moving to transverse direction, also the displacements are happening to road and vertical direction at the same time. Presently, the accumulated displacement between sensing points shows small value within 4.3 cm, and the displacements of all sensing points show the similar directions and magnitudes.