• 제목/요약/키워드: slump test

검색결과 411건 처리시간 0.025초

초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용 (Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

조강시멘트를 이용한 속경성 자기충전 콘크리트의 배합인자별 품질특성 및 활용에 관한 연구 (Study on the qualities & application of Super High Early Strength -Self Compact Concrete using Type III Cement for productabilities-)

  • 엄태선;임채용;유재상;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.573-578
    • /
    • 2002
  • We carried out the feasibility study of super early self compacting concrete having the characteristics of 1 day demoulding without steam curing, high flowable concrete with self compacting, high strength and high durability etc. Here, We test and selected by several methods using high early cement with and without admixtures for the condition of super early strength self compacting concrete's manufacture (SSCC). We sucessed to meet at the goal of SSCC with 30∼35N/㎟ in 1 day, without steam curing and with slump flow about 60-65cm and suggest various concrete products to apply the developed SSCC for practical use in factory and in site place

  • PDF

고로슬래그 미분말을 혼합한 고강도 수중불분리성 콘크리트 (High-strength Antiwashout Underwater Concrete Containing the GGBF Slag)

  • 문한영;송용규;전중규;김태욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.199-202
    • /
    • 1999
  • Recently, the antiwahout underwater concrete with an natiwashout admixture has been increasingly used for underwater structures. However, the credibility of antiwahout underwater concrete was brought up as problems because it was seldom applied to fields. In this study, experiments were made on the basic properties of antiwashout underwater concrete replaced with GGBF Slag from 40% to 60% to improve its properties. Resultant to the test, we got the results as follows; the difference of U-type heght was decreased, and the slump flow was increased. Whereas the amount of suspended solids became high as to increasing the replacement ratio of GGBF Slag, pH value became low. Beacause the ratio of compressive strengths (in water compared to in air) at 28days was obtained over 90%, its value is satisfied with 70% of a criterion.

  • PDF

한중콘크리트에 있어서 폐부동액을 이용한 내한제의 효율성에 관한 기초적 연구 (A Fundamental Study on the Effectiveness of Anti-freeze Agent Using Waste Coolant in Cold Weather Concreting)

  • 김경민;원철;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.231-236
    • /
    • 2001
  • In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.

  • PDF

폐유리를 활용한 콘크리트의 물리.역학적 특성에 관한 실험적 연구 (An experimental Study on the Physical.Mechanical Properties of Concrete Utilizing Waste Glass Aggregate)

  • 김정환;조광연;조청휘;이봉춘;박승범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.251-256
    • /
    • 2001
  • Recently, as industrialization is rapidly growing and the standard of life is rising, the quantities of waste glasses have been hastily increased and most of them are not recycled but abandoned. It cause some problems such as the waste of natural resources and environmental Pollution. Therefore, this study was conducted basic experimental research to analyze the possibilities of recycling of waste glasses(crushed waste glasses outbreaking from our county such as brown, green, colorlessness) as fine aggregates for concrete. Test results of fresh concrete, slump and compacting factors decrease because grain shape is angular and air content increase due to involving small size particles so much in waste glasses. Also compressive, tensile and flexural strengths decrease with increase of the content of waste glasses. In conclusion, the content of waste glasses below 30% is reasonable

  • PDF

부순모래를 사용한 고강도콘크리트의 특성 및 레미콘 B/P 적용에 관한 연구 (A Study on the Remicon B/P Application and Properties of High Strength Concrete using Crushed Sand)

  • 최세진;이성연;이상수
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2007
  • Generally, the strength of concrete depends on factors of materials, mix proportions, compaction, manufacturing methods and curing and so on. And recently, it has increased the using of crushed sand for concrete due to the exhaustion of good natural aggregate. In case of Korea, in 2004, the using ratio of crushed sand occupies about 28% of whole fine aggregate. This is an experimental study to compare and analyze the influence of W/B ratio and replacement ratio of crushed sand on the fluidity and compressive strength of high strength concrete. For this purpose, the mix proportions of concrete according to the W/B (31.5, 27.5, 23.5%) and replacement ratio of crushed sand (0, 20, 40%) was selected. And then air content, slump-flow, a-lot, compressive strength test were performed.

폐유지류 혼입에 따른 플라이애시 다량 치환 콘크리트의 기초적 특성 (Fundamental Properties of High Volume Fly Ash Concrete due to Waste Oil Addition)

  • 김준호;황금광;조만기;허영선;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.67-69
    • /
    • 2012
  • This paper is to investigate the effect of waste oil on the fundamental properties of high volume fly ash concrete depending on W/B and waste oil contents. Test results reveals that the use of waste oil resulted in an increase of slump and a decrease of air contents due to the presence of emulsion in waste oil. And it is found that the addition of waste oil does not affect the strength development of the concrete significantly.

  • PDF

매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 현장 적용 -대전 가오지구 코오롱 하늘채 아파트 현장- (Field Application of Setting Time Difference Method Using SRA for Reduction of Hydration Heat of Mass Concrete)

  • 전충근;김종;신동안;윤기원;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.21-24
    • /
    • 2005
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows $25.6^{\circ}C$, and at bottom section, $35.4^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

열병합발전소의 열원폐자재를 골재로 활용한 콘크리트특성에 관한 연구 (The Study on Application of a Heat annexation power plant Source Waste Aggregate as Concrete Aggregate)

  • 이명효;김효열;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2005
  • This study is as a part of the new disposal and recycling plans of heat-resource waste of Daegu dyeing, industrial center we tried to examine applicable possibility of crushed thing(waste aggregate) as aggregates for mortar and concrete. To examine applicable possibility of waste aggregate as a lightweight-aggregate for concrete and mortar, we carried this study by mainly property examination of concrete according to replacement ratio of waste aggregate. We carried slump, unit weight, compressive strength and bending strength test according to replacement ratio of waste aggregate. As the result of that, if we use waste aggregate, lightweight of concrete and mortar will be possible. Specially it shows a strength improvement effect of cement hardening according to using this so it is judged that applicable possibility as aggregate for concrete and mortar is very excellent.

  • PDF

초기 재령에서 잔골재율의 변화에 따른 고강도 콘크리트의 수축특성 (Shrinkage Properties of High Strength Concrete According to S/A in Early Age)

  • 박신일;전철송;임병호;이승훈;손상현;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1135-1140
    • /
    • 2001
  • The purpose of this study is to investigate the shrinkage properties of high strength concrete according to the S/A ratio at early age. The main parameters are as follows : S/A ratio is 30, 35, 38, 41, 45%, W/B ratio 24.9%, SF/B ratio 8%. FA/B 15%. The size of specimen is l0$\times$10$\times$40cm and the shrinkage is measured by the embedded gage at each end of the specimens. From the test, it was found that the slump-flow of concrete was high, and also autogenous shrinkage increased and drying shrinkage decreased as S/A ratio increased.

  • PDF