• Title/Summary/Keyword: sludge storage tank

Search Result 8, Processing Time 0.01 seconds

Quantitative Study of the Reformation of Excess Sludge by Intense Aeration Under Nutrient-poor Conditions

  • L Guang Wei;Chen Liming;Toda Kiyoshi;Zhang Shuting
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.519-522
    • /
    • 2004
  • In the course of anaerobic storage of excess sludge, odors due to chemicals such as hydrogen sulfide are produced. These odors cause many problems. Many methods have been developed to eliminate odors, but all current methods are not only costly, but also largely inef­fective. In this paper, we investigate the process of transformation of sludge microorganism cul­tures through intense aeration under nutrient-poor conditions, in terms of the selective adjust­ment and control of microorganism culture. The aerated sludge is subsequently returned to the adjusting pool, where the microorganisms inhibit odors, thus the excess sludge itself will act as an odor inhibitor. The process can be verified in terms of viability, in that the degradation capac­ity of the sludge was maintained after the intensely-aerated sludge was returned to the treat­ment system.

Dewatering characteristics of sludge generating water treatment plant (정수장슬러지의 탈수특성)

  • Kim, Eun-Ho;Lee, Mi-Kyung;Kim, Hyeong-Seok;Sung, Nak-Chang;Heo, Jong-Soo;Hwang, Young-Gi
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.316-320
    • /
    • 1999
  • The purpose of this research was to estimate dewatering characteristics of generating water treatment plant by dewatering velocity, suitable polymer and mixing condition. Zeta potential of sludge in storage tank was negative and in case of adding cation, anion and nonion polymer for sludge conditioning, specific resistance coefficients of conditioned sludge were similar at zeta potential -5㎷. But above zeta potential -15㎷, canon polymer was more effective than others for reduction of specific resistance coefficients. Using of cation acrylate polymer showed better dewatering coefficients than cation methacrylate polymer.

  • PDF

The Effect of Organic Matter and Lime Treatment on Trichloroethylene Adsorption by Soil (유기물과 석회 처리 수준이 토양의 Trichloroethylene 흡착에 미치는 영향)

  • 이군택;류순호;이민효
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1996
  • Trichloroethylene(TCE) is the organic compound which is used variously at the industrial areas. It contaminates soils and groundwater by leaked storage tank, careless treatment in field and the effluent from waste landfills. This study was carried out to identify adsorptive behavior of TCE by soil. Batch experiments were conducted at different soil-organic matter content and lime treatment to determine Freundlich isothermal adsorption equation constant, k and n, for TCE. Sewage sludge cake was applied to make different soil-organic matter content with the level of Oton/ha(S1), 50ton/ha(S2), 100ton/ha(S3). Lime(calcium hydroxide) was treated with the level of 2ton/ha, 4ton/ha, 6ton/ha, 10ton/ha. Freundlich isothermal adsorption equations obtained from experiment with sewage sludge cake were as follows (on condition that the level of TCE applied to soil ranged from 0.5ng/g soil to 2.5 ng/g soil.) : S1 :x/m = 0.393 $C^2$, S2 : x/m = 0.436 $C^2$, S3 : x/m = 0.636 $C^2$Value of k was increased in higher order of 51, 52, 53 with increased level of sewage sludge cake application. From this results, soil which was applied higher level of sewage sludge cake had a good ability on TCE adsorption. With increased the level of lime application, pH of the soil was increased and the ability of the soil in TCE adsorption was decreased.

  • PDF

Development of an Solid Separation System for Pig Slurry (돈 슬러리용 고형물 분리시스템 개발)

  • 김민균;김태일;최동윤;백광수;박진기;양창범;탁태영
    • Journal of Animal Environmental Science
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was conducted to develope the new solid separating system which can be efficiently and economically removed the solid parts in high pollutants concentration of pig slurry. The pollutants concentration, BOD$_{5}$ , COD and SS of the slurry used in this study was 15,990($\pm$2,389)mg/l, 20,004($\pm$5,512)mg/l and 26,486($\pm$5,935)mg/l, respectively. After removal of solid part in slurry, the pollutants concentration, BOD$_{5}$, COD and SS was change into 5,617($\pm$690)mg/l, 5,553($\pm$633)mg/land 1,456($\pm$341)mg/l, respectively in the Fixed biological membrane tank. The reduction of the pollutants concentration of suspend liquid through membrane will be allowed to greatly improve the water purification by an Activated sludge method. This separating system consisted of a temporary storage, a circulating tank and a Fixed Biological membrane tank. A temporary storage which has a draining system of screw type and an aeration device played a tremendous role in draining the solid by filled an aeration of 0.3 l/min. A Fixed Biological membrane tank of which a styrofoam filled in a 2/3 volume as a Biological media was fixed by a stainless steel net (pore size : 0.5mm) to separate the liquid layer of influx in them. The separating system efficiency factors were the speed of screw motor, cycle number of slurries in a circulating tank and moisture contents of solid effluent through the screw path. Although the pollutants concentration was very variable in temporary storage, the final concentration of $BOD_5$ and SS, except COD of the suspended liquid in a Fixed biological membrane were not different regardless of cycle number of a circulating tank. Moisture contents of effluent from temporary storage was 73% under the speed 1 ppm of screw motor and 62% under the 1/4rpm of it.

  • PDF

Removal of Nutrients from Stream Water Polluted with Nonpoint Source Pollution by Cultivation of Phytoplankton. (비점오염원으로부터 오염된 하천수에서 식물플랑크톤 배양을 이용한 영양염류 제거)

  • Cho, Ahn-Na;Jung, Da-Woon;Jung, You-Jung;Choi, Seung-Ik;Ahn, Tae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A phytoplankton cultivation system was installed and operated for removal of nutrients from stream water polluted by nonpoint source pollution. The system was a continuous-flow culture comprising a phytoplankton tank that received inflow from a storage reservoir. When the system was operated as a batch culture for the purpose of determining hydraulic retention time (HRT), the proper HRT value was three days, and the removal rate of TP and TN averaged 70% and 44%, respectively. When the system was operated with the continuous flow from a stream for 45 days, 53.9% of TP and 53.1% of TN were removed as sludge. Due to active growth of phytoplankton, pH and dissolved oxygen in the phytoplankton tank were extremely high, reaching 10.8 and 16mg $L^{-1}$, respectively. It was concluded that nutrients can be effectively removed from polluted stream waters by cultivating phytoplankton.

Dewaterability Improvement and Volume Reduction of Bio-Solid using Ultrasonic Treatment (Bio-Solid의 탈수성 개선 및 감량화를 위한 초음파 적용)

  • Park, Cheol;Ha, Jun Soo;Kim, Young Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.4019-4023
    • /
    • 2014
  • This study examined the effectiveness of ultrasound on enhancing the dewaterability and volume reduction of bio solids from a waste treatment plant. The test specimen was obtained from a storage tank immediately before the dewatering process at a local treatment plant. The test conditions included the energy levels of ultrasonic waves and treatment time. The tests were undertaken using three types of different treatment processors (7 liter, 1 ton, 7 ton container). The capillary suction time (CST) and the viscosity of sludge, which is one of the influencing factors for dewaterbility, were obtained under various test conditions. The results showed that ultrasound increases the CST of the raw specimens, whereas a significant reduction (20 % of the maximum value) of CST occurred in the sample with ultrasound and flocculent. The decrease in viscosity reached 40 % of the maximum value. A centrifugal test was performed to examine the characteristics of the sludge settlement. The settling rate and time required to reach the final values were both enhanced by the ultrasonic energy. An ultrasonic treatment is potentially useful tool for reducing the amount of released sludge. To examine the possible use of field application, the real scale sonic processor was designed and operated. The results were similar (50 % of the maximum value) to those of laboratory experiments.

Exposure Assessment of Hazardous gases in Confined Spaces (밀폐공간 종류별 유해가스 발생 농도 평가)

  • Park, Hyunhee;Yoo, Kye-mook;Ham, Seung-hon;Chung, Kwang-Jae;Shin, Min-a;Lee, Koo-yong;Jang, Kyung-jo;Yoon, Chung-sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.381-389
    • /
    • 2009
  • Confined spaces are inherently dangerous workplace and many fatal and nonfatal accidents have been reported. Even though these accidents occur in various kinds of confined spaces, there has rarely been reported on the health hazard agent, i.e., the types of gases and their concentration ranges. Therefore in this study, we evaluated several toxic and asphyxiating gas concentrations in various confined spaces. We surveyed 57 manholes, 3 sewage treatment plants, 2 yellow radish manufacturing companies and 7 barges to measure the concentrations of oxygen($O_2$), hydrogen sulfide($H_2S$), carbon monoxide(CO), ammonia($NH_3$). Lower Explosion Limits(LEL) and Volatile Organic Compounds (VOCs). Those four types of confined spaces occupies 56% of accidents during last 9 years in Korea. In 57 manholes, the concentration varied according to the types of manholes; rainfall and sewage, and by location; residential and industrial areas. Sewage manhole in industrial area was evaluated as the most hazardous than other types of manhole like rainfall manholes, residential sewage manholes. The highest $H_2S$ concentration and the lowest $O_2$ concentration at sewage manhole in industrial area were 300 ppm, 8.7% respectively. In 3 sewage treatment plants, $H_2S$ and $NH_3$ concentrations were reached up to the 500 ppm and 200 ppm respectively. Two yellow radish manufacturing companies showed the concentrations of 316 ppm, 505.2 ppm, 90 ppm and 15.7% for $H_2S$, CO, VOCs and $O_2$, respectively. Seven barges showed 15.9%~20.9% oxygen concentration. Gas species and concentration ranges varied by the types and location of confined spaces; CO, $H_2S$, $O_2$ could be hazardous in manhole, especially manhole connected to sewage plants. CO, $H_2S$, LEL, $O_2$, $NH_3$ should be controlled in sludge silo and sluge pumping confined spaces in sewage treatment plant. The activity of lifting out radish from the storage tank was evaluated more hazardous rather than the other activities in yellow radish manufacturing industry. The employers must conduct the survey to identify all possible confined spaces in their local workplace prior to performing the tasks. At the national level to reduce the accidents in the confined spaces, we suggest that systemic approach and active education program including possible hazards, standard operation procedures, ventilation plan, and personal protective equipment in confined spaces should be implemented.

Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process (식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가)

  • An, Sang-Hyung;Song, Jang-Heon;Kim, San;Chung, Jin-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.378-384
    • /
    • 2019
  • In the food wastewater treatment facilities, the water quality improvement effect and the greenhouse gas emission amount followed by the change in electricity usage through a change of the aeration tank ventilation system were evaluated. also, the amount of greenhouse gas emission followed by the change in electricity usage through the change of the sludge dewatering, storage, transporting method was also evaluated. The total GHG emission from food wastewater treatment facility improvement were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The water quality improvement effect of wastewater treatment plant was found to be 63.3% for BOD removal rate, 42.0% for COD removal rate, 71.0% for SS removal rate and 39.6% for T-N removal rate. and according to the results of calculating output by applying both direct emissions of greenhouse gas (Scope 1) and the indirect emission (Scope 2) of greenhouse gas followed by changes in power consumption. It was estimated that there was a total of 276.0tCO2eq./yr(7.5%) greenhouse gas reduction effect from 3,668.8tCO2eq./yr before improvement to 3,392.8tCO2eq./yr after improvement. In this result is not due to the effects of water quality improvement of emission source, but because the reduction in electricity use has reduced the amount of greenhouse gas emissions.