• 제목/요약/키워드: sludge solids

검색결과 179건 처리시간 0.028초

Influence of sludge solids content on sludge dewaterability using bioleaching

  • Wong, Jonathan W.C.;Zhou, Jun;Zhou, Lixiang;Kurade, Mayur B.;Selvam, Ammaiyappan
    • Advances in environmental research
    • /
    • 제3권3호
    • /
    • pp.199-206
    • /
    • 2014
  • Dewatering is an extremely important step in wastewater treatment process to reduce the final sludge volume in order to minimize the cost of sludge transportation and disposal. In the present study, the effect of different sludge solids content (1, 2 and 3.8%) on the dewaterability of anaerobically digested sludge using Acidithiobacillus ferrooxidans and Acidithiobacillus thiooxidans was studied. The pH reduction rate was higher during initial process in the sludge having low solids content, but after 48 h of bioleaching, similar pH of below 3 was observed with all the different solids content. Bio-oxidation rate of $Fe^{2+}$ was initially higher in sludge with low solids content, but 100% $Fe^{2+}$ was oxidized within 60 h in all the three treatment levels. Compared to the control, specific resistance to filtration was reduced by 75, 78 and 80% in the sludge with a solids content of 1, 2 and 3.8% respectively, showing improvement in dewaterability with an increase in sludge solids content. Sludge effluent quality and sludge settling rate were also improved in treatments with higher solids content after the bioleaching process.

생물반응공정에 대한 고액분리조로서 부상공정의 적용성 평가 (An assessment on feasibility of flotation as a secondary clarifier of an activated sludge process)

  • 정종민;김윤중;조강우;이상협;홍석원;정태학
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.551-559
    • /
    • 2008
  • An experimental study was carried out to evaluate the potential of flotation process for the secondary clarifier of an activated sludge process. Flotation techniques, applied in this study, include electrofloation (EF) which generated fine bubbles smaller than $35{\mu}m$ in average and diffuser flotation (DF) which generated fine bubbles smaller than $55{\mu}m$ in average. The batch experiments were done with activated sludge displaying various characteristics. It was shown that the efficiency of solids/liquid separation was reduced as the diluted sludge volume index ($DSVI_{30}$) of activated sludge increased. The dependency, however, gradually decreased as the gas to solids (G/S) ratio increased. Thickening efficiency of EF was more than 2~10 times and DF process was more than 1.5~5 times as compared with gravity sedimentation (GS). Stable sludge blanket was maintained regardless of sludge settleability when the G/S ratio was 0.019 in the EF. On the other hand, Serious deterioration in the sludge blanket was observed in the DF depends on G/S ratio and sludge settleability. And For EF and DF, the suspended solids concentration of effluent was not nearly influenced on settleability of activated sludge and more clear than GS. A biological nutrient removal (BNR) process, combined with EF as a secondary clarifier was operated for three months. The mean MLSS (mixed liquid suspended solids) concentration in the reactor and mean solids concentration of return sludge were estimated to be 5,340 mg/L and 16,770 mg/L, respectively. The water quality of effluent was considerably stable and low value was accomplished, that was, standard suspended solids concentration $0.07{\pm}0.51mg/L$ and standard turbidity $1.44{\pm}0.56NTU$. The EF could be applicable for enhancement of efficiency of activated sludge system as well as improvement of the water quality of effluent.

슬러지 전처리와 고농도 MBR을 이용한 슬러지 감량화 공정연구 (Performances of a Sludge Reduction Process Using High Concentration Membrane Bioreactor with Sludge Pretreatment)

  • 한규철;염익태;정우진;김형수
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.559-566
    • /
    • 2003
  • From this research, the performances of a sludge reduction in the sewage sludge aerobic digestion was experimented by using a sludge pretreatment and membrane bioreactor. The submerged plate membrane was used as the solid-liquid separation membrane. After drawing small amounts of sludge in a bioreactor and then doing the alkaline treatment and ozone treatment, the sludge was sent to back to the reactor. The HRT in the reactor was set as 5 days and the operation in the reactor was carried out at the DO of 1mg/L on average. After 100 days of operation in the reactor, it was shown that the reduction efficiency of total solids was more than 83%. Most of volatile solids were removed through mineralization, and the considerable portion of the non-volatile solids was dissolved and then flowed out with the effluent. Only about 16.3% of total solids in the sludge was accmulated in the reactor even without the loss of volatile fraction. Also, by deriving nitrification and denitrification in one reactor simultaneously, more than 90% of nitrogen removal effect was realized and the experiment was run smoothly without fouling of membrane, even in the high concentration of MLSS. Based on this experiment, sludge can be reduced considerably at a low HRT by these two newly suggested approach.

정수장에서 발생된 탈수슬러지의 량에 의한 배출수처리시설용량에 대한 평가 (Estimation on the Design Capacities of Residuals Treatment Facilities by the Quantity of Dewatered Sludge Generated from Water Treatment Plants)

  • 문용택
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.715-723
    • /
    • 2004
  • The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS occurs under quiescent conditions in the primary clarifier, where suspended solids are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. The relative solid and liquid fractions of a slurry are most commonly described by the solids concentration, expressed as mg/L or percent solids. The purpose of the present investigation is to estimate a suitability on the design capacities of residuals treatment facilities by the quantity of dewatered sludge generated from water treatment plants.

도시 하수 및 공장 폐수 슬러지의 바이오가스화에 관한 연구 (A Study on the Biogasification of Municipal and Industrial Wastewater Sludge)

  • 김자현;김석구;황인주;안재환;강성원;이원태;임준혁;이제근;이태윤
    • 한국지반환경공학회 논문집
    • /
    • 제15권9호
    • /
    • pp.5-12
    • /
    • 2014
  • 슬러지의 안정화, 휘발성 고형물 감소, 바이오가스 생산을 위해 혐기성 소화공정이 슬러지의 처리 방안으로 연구됐다. 본 연구에서는 하 폐수 슬러지(MWS, IWS), 혼합슬러지(Mix), 탈수슬러지(MWSC)를 대상으로 바이오가스 생산 가능성을 살펴보기 위해 Total solids, Volatile solids, 원소분석, BMP 실험을 하였다. Total solids 함량은 11.2~20.6 %의 값을 가지며 Volatile solids의 함량은 TS의 62.1~83.1 %의 값을 가지고 있다. C/N비는 4.96~8.33의 값을 나타났다. BMP test를 한 결과 혼합슬러지의 경우 약 20일, 하 폐수 슬러지의 경우 약 16~17일에 메탄발생이 종료되었다. 탈수케이크는 약 10일까지 메탄이 발생하였으며 가장 빨리 메탄발생이 종료되었다. 누적 메탄발생량의 경우 혼합슬러지가 395.50 mL $CH_4/g$ VS으로 가장 높은 누적 메탄 발생량을 가진다. 누적 이산화탄소 발생량은 탈수케이크를 제외하고 비슷한 값을 보이고 있다.

중온 혐기성 연속회분식 공정에 의한 도시하수슬러지의 소화가능성 평가 (Application of Anaerobic Sequencing Batch Reactor to Mesophilic Digestion of Municipal Sewage Sludge)

  • 허준무;장덕;정태학;손부순;박종안
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.9-19
    • /
    • 1998
  • Laboratory experiments were carried out to investigate the performance of anaerobic sequencing batch reactor(ASBR) for digestion of a municipal sludge. Each cycle of the ASBR comprised feeding, two-or three-day reaction, one-day thickening, and withdrawal. The reactors were operated at an HRT of 10days and 5days with an equivalent organic loading rate of 0.8-1.54 gVS/l/d, 1.81-3.56 gVS/l/d at 35$\circ$C, respectively. Solids accumulation was remarkable in the ASBR during start-up period, and directly affected by settleable solids in the feed sludge. Floatation thickening occured in the ASBRs, and Solids profiles at the end of thickening step dramatically changed at solid-liquid interface. Slight difference in solids concentrations was observed within thickened sludge bed. Efficiencies through floatation thickening were comparable to that of additional thickening of the completely mixed control reactor. Average solids concentrations in the ASBRs were 2.2-2.6 times higher than that in the control throughout the total operation period. The dehydrogenase activity had a strong correlation with the solids concentration. Organics removals based on clarified effluent of the ASBRs were consistently above 86%. Remarkable increase in equivalent gas production of 27-52% was observed at the ASBRs compared with the control though the control and ASBRs showed similiar effluent quality. Thus, digestion of a municipal sludge was possible using the ASBR in spite of high concentration of solids in the sludge.

  • PDF

전해부상에 의한 상수 슬러지 농축효율 (Sludge Thickening using Electro-Flotation in Water Treatment Plant)

  • 이준;한무영;독고석;박용효;김충일;김미경
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.155-160
    • /
    • 2005
  • Gravity thickening process has been widely used in WTP sludge thickening at domestic water treatment plant. The operation method of the process is very simple, however, the process requires long detention time about 24~48 hours for sludge thickening, uses polymer, and low total solids of thickened sludge to increase sludge thickening efficiency. To solve there problems, we studied about flotation process, especially, electro-flotation (EF) process in WTP sludge thickening. Electro-flotation process is simpler than dissolved-air-flotation(DAF) process because EF needs only electrode and current to generate micro-bubbles and the operation is easy. This study was performed at two batch columns to compare interface height, total solids, effluent turbidity between an electro-flotation thickening and a gravity thickening. According to the result, an electro-flotation thickening was that interface height was decreasing, total solids had high concentration, and effluent turbidity was low in comparison with a gravity thickening. Also, it will make the high efficiency of following process, such as a dehydrating process and digestive process. because of high total solids and low moisture content in the sludge.

혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가 (Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation)

  • Hur, Joon-Moo;Park, Jong-An
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.77-85
    • /
    • 2002
  • 중온과 고온의 혐기성 연속회분식 공정(anaerobic sequencing batch reactor ; ASBR)에서 소화슬러지의 고액분리특성이 처리효율에 미치는 영향을 규명하고자 하였다. 연구결과 침전가능 고형물농도가 높은 도시하수슬러지 처리시 고액분리특성 및 고액분리형태가 전체처리의 안정성 및 처리효율에 상당한 영향을 미쳤다. 중온ASBR에서는 부상농축현상이 일어났으나, 고온ASBR에서는 중력농축에 의한 고액분리가 일어났으며, 상대적으로 고온 ASBR의 처리효율이 우수하였다. 그리고 수리학적 체류시간, cycle period 및 고액분리형태는 소화슬러지의 농축 특성과 임계 고형물농축을 지배하는 중요한 인자였다. 중온ASBR에서 고액분리 후 농축슬러지베드용적(thickened sludge bed volume)은 매우 중요한 운전 요소이며, 소화슬러지의 중력농축특성은 배출시 농축고형물의 유실현상과 침전시 계속적으로 발생하는 소화가스에 의한 슬러지계면의 파괴현상 및 슬러지베드의 불안전성을 야기시켜 처리효율을 감소시켰다. 중력농축의 경우 소화가스와 슬러지농축용적간의 상호작용(cyclic mutual effect)이 주기적으로 일어났으나, 부상농축에서는 이러한 현상이 일어나지 않았다.

SRF측정에 의한 하수슬러지의 탈수 개선을 위한 오존 효과 (The Effect of Ozone of the Improvement of Dehydration in Treatment of Sewage Sludge Measuring SRF)

  • 황상용;손종렬;이용성
    • 한국환경보건학회지
    • /
    • 제19권4호
    • /
    • pp.44-50
    • /
    • 1993
  • This paper has concentrated on estimating the improvement of sludge dewaterability for the application of ozone in sewage treatment plant sludge. The experiment for the study was conducted by batch reactor, contacting ozone (5.0 g O$_3$/hr/l) to waste sludge and measured the Specific Resistance to Filtrate (SRF) varying pH, pressure and reaction time of ozone. And then checked the dissolved solids concentration of flitrate. The results of experiment were as follows: 1. When the total solids concentration of excess sludge was 9, 000 mg/l, the optimum injection rate of ozone was 5.0 g O$_3$/hr/l, and then pressure was 50 cm Hg for the measuring SRF. 2. In the range of pH 3~5, the effect of ozone injection was excellent, but it was unsatisfactory in the range of pH 9~11. Therefore, the ozone injection by acidifying pH level was effective in improving the dewaterability of sludge. 3. It was estimated that the dissolved solids concentration of flitrate was increased in proportion to the injection rate of ozone.

  • PDF

총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구 (Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank)

  • 김종오;정동기;권혜정;황준석
    • 한국수처리학회지
    • /
    • 제26권6호
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.