• 제목/요약/키워드: slope reinforcement

검색결과 282건 처리시간 0.025초

완경사 사면붕괴 지역의 안전성 보강대책 연구 (A Study on Reinforcement for Slope Stability of Gentle Inclination Slope Collapse Occurrence Area)

  • 이승호;황영철;조성민;노흥제;이은동
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.83-91
    • /
    • 2003
  • Always slope according to construct road exist danger because of environment unstability factor in slope, Since this research an inclination of slope is gentle slope (1:1.5∼1:9.0) but falling happened by conduct of continuous ground movement. And this study considered more economical and efficient reinforcement method for slope stability. The various reinforcement methods are applied to execute examination of slope stability. Applied reinforcement methods satisfied safety factor And this research region is performing continuous measurement about ground movements and displacements.

  • PDF

사면녹화 보강토공법의 보강재길이 산정에 관한 연구 (The Computation of Reinforcement Length of Afforestation Slope)

  • 박춘식;남광온;김종환;이수양
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1302-1308
    • /
    • 2010
  • This study the change of the safety factor before and after the reinforcement were compared by performing the parameter research based on the limit equilibrium analysis regarding the same cross section after carrying out the safety factor before the reinforcement on the virtual section in order to observe the change of the safety factor of the slop reinforced with the slope planting reinforced earth, and the variation of the safety factor according to the increase of the length of the reinforcement materials and the change of the slope height was analyzed. As the result, the reinforcement effect was insignificant at no more than 0.6 of L/H, the reinforcement length ratio when the reinforcement length was increased, as the increase of the safety factor was slow comparing with the non-reinforced slope. At 3.0m of the slope height, reinforcement on the slope is not necessary, and at 3.0m to 5.0m of the slope height, the inclination was not influencing at no less than 0.6 of L/H. At 5.0m to 9.0m of the slope height, the safety factor was mostly secured on the slope at 0.8 of L/H and the over-reinforced slope appeared at no less than 1.0 of L/H. Also, the safety factor increased as the slope height increases and the slope gets steeper till 0.8 of L/H, but the slope steepness affects more on the increase of the safety factor than the reinforcement material, as the reinforcing force by the reinforcement material became steady.

  • PDF

사면보강 공사시 관리 방안 (Plan of Construction Management for Reinforcement Method of Slope)

  • 박종호;정희석;이재덕;홍익표
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.44-51
    • /
    • 2002
  • The construction road and addition work are increasing now. Therefore, slope stability is important in construction slope on the fault and fractured zone. Rock bolt method, soil nailing method and anchor method are applied to reinforcement method of slope. This paper is the study for construction management on reinforcement method of slope.

  • PDF

사면보수보강을 위한 FPF 보강공법개발 (FPF(Fibrillated Polypropylene Fiber) Reinforcement Method for Slope Repair)

  • 김낙경;박동원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.257-264
    • /
    • 2001
  • This study presents the slope stability analysis results for the model slope test. The model slope was made of the soil reinforced by FPF(Fibrillated Polyprophylene Fiber). The shear strength properties of the soil reinforced by FPF fibers were evaluated through the direct shear tests. The model slope 1:1 and 1:1.5 were made and the load tests were performed. Back analysis using limit equilibrium method was carried out to evaluate the shear strength increase on the FPF reinforced slope. The factor of safety of the FPF reinforce slope increased about 23% over unreinforced slope.

  • PDF

절개사면에서의 보강단계별 사면안정성에 대한 해석적 연구 (An Analytical Study of Slope Stability to Reinforcement Stage in Cut Slope)

  • 강기천;송영석;홍원표;김태형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.724-731
    • /
    • 2006
  • The purpose of this study is to estimate a landslide using the SLOPILE program from the slope reinforced by slope stability systems such as soil nailing and pile. To do this, cutting slope located at Donghae-Highway in Kwangwon-Do was considered. The behavior of slope was monitored for a long term by using instrumentation according to the reinforcement stages. The sequence of reinforcement stages was followed as pile installation, boring, soil nailing installation, anchoring and embankment. The result from this case study shows that the safety factor of slope depends on the reinforcement stage more or less.

  • PDF

사면보강공법 시공불량사례 검토를 통한 개선방안 연구 (A Case study on the construction badness for slope reinforcement)

  • 권성주;김용수;장범수;나광희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.739-744
    • /
    • 2005
  • The construction road work are increasing now. And the domestic slope construction are steadily increased and changed the complicated and large-scale. Therefore ground reinforcement for slope stabilization has been increasingly used during the past few decades with a wide variety of techniques including soil nailing, rock bolt, anchor and different types. But in some cases which applied slope reinforcement construction by badness or mistake. So this paper is the study of construction badness for slope reinforcement.

  • PDF

Numerical investigation of geocell reinforced slopes behavior by considering geocell geometry effect

  • Ardakani, Alireza;Namaei, Ali
    • Geomechanics and Engineering
    • /
    • 제24권6호
    • /
    • pp.589-597
    • /
    • 2021
  • The present study evaluates geocell reinforced slope behavior. A three dimensional analysis is carried out to simulate soil and geocell elastoplastic behavior using the finite difference software FLAC3D. In order to investigate the geocell reinforcement effect, the geocell aperture size, thickness, geocell placement condition and soil compaction had been considered as variable parameters. Moreover, a comparison is evaluated between geocell reinforcing system and conventional planar reinforcement. The obtained results showed that the pocket size, thickness and soil compaction have considerable influence on the geocell reinforcement slope performance. Moreover, it was found that the critical sliding surface was bounded by the first geocell reinforcement and the slope stability increases, by increasing the vertical space between geocell layers. In addition, the comparison between geocell and geogrid reinforcement indicates the efficiency of using cellular honeycomb geosynthetic reinforcement.

압성토 및 억지말뚝으로 보강된 도로의 확장공사로 인한 추가 보강사례 연구 (A Case Study of Extra Reinforcement by Road Extension work on Existing Cut Slope Reinforced with Counterweight Fill and Stabilizing Piles)

  • 박정용;김우성;김제경;양태선;나경준
    • 한국재난관리표준학회지
    • /
    • 제1권2호
    • /
    • pp.67-72
    • /
    • 2008
  • 본 논문에서는 도로확장공사 현장의 절토사면 안정검토를 위해서 몇가지 조사 및 분석을 수행하였다. 압성토 및 억지말뚝으로 보강된 절토사면의 추가 보강사례를 그 연구대상으로 하며, 절토사면에 보강된 안정화파일의 효과를 분석하기위한 시험장비 또한 설계 및 설치하였다. 결론적으로, 추가보강방법으로써 억지말뚝공법과 Earth Anchor공법을 검토한 결과, 억지말뚝공법과 Earth Anchor공법 모두 안정성은 확보하였으나 기존 보강공법의 연계성과 경제성을 고려하여 억지말뚝공법을 추가보강공법으로 선정하였다.

  • PDF

The behaviour of a strip footing resting on geosynthetics-reinforced slopes

  • Hamed Yazdani;Mehdi Ashtiani
    • Geomechanics and Engineering
    • /
    • 제34권6호
    • /
    • pp.623-636
    • /
    • 2023
  • This study utilized small-scale physical model tests to investigate the impact of different types of geosynthetics, including geocell, planar geotextile, and wraparound geotextile, on the behaviour of strip footings placed on 0.8 m thick soil fills and backfills with a slope angle of 70°. Bearing capacity and settlement of the footing and failure mechanisms are discussed and evaluated. The results revealed that the bearing capacity of footings situated on both unreinforced and reinforced slopes increased with a greater embedment depth of the footing. For settlement ratios below 4%, the geocell reinforcement exhibited significantly higher stiffness, carrying greater loads and experiencing less settlement compared to the planar and wraparound geotextile reinforcements. However, the performance of geocell reinforcement was influenced by the number and length of the geocell layers. Increasing the geocell back length ratio from 0.44 to 0.84 significantly improved the bearing capacity of the footing located at the crest of the reinforced slope. Adequate reinforcement length, particularly for geocell, enhanced the bearing pressure of the footing and increased the stiffness of the slope, resulting in reduced deflections. Increasing the length of reinforcement also led to improved performance of the footing located on wraparound geotextile reinforced slopes. In all reinforcement cases, reducing the vertical spacing between reinforcement layers from 100 mm to 75 mm allowed the slope to withstand much greater loads.

지오그리드로 보강된 도로제방 사면의 안정성 해석 (Stability Analysis of Road Embankment Reinforced by Geogrid)

  • 이한민;유한규;서영찬;박언상
    • 한국지반환경공학회 논문집
    • /
    • 제2권4호
    • /
    • pp.39-50
    • /
    • 2001
  • 본 연구에서는 지오그리드로 보강된 도로제방 사면에 대해 한계평형해석에 근거한 보강사면해석 프로그램인 RSS를 이용하여 보강길이와 간격의 변화에 따른 사면의 안전율 변화를 살펴보았다. 해석결과 비보강시 기준안전율을 만족하지 못하는 사면에서 보강재길이의 증가에 따라 비보강사면에 비해 최대 50~150%의 안전율이 증가되었으며 보강길이를 증가시켜도 안전율의 추가상승이 없는 한계길이를 확인하였다. 또한 동일 가상보강단면에 대하여 범용프로그램인 FLAC을 이용하여 유한차분해석을 실시하여 안정성이 확보된 사면에 발생하는 수평변위, 수평응력, 보강재의 인장력을 산출하여 보강길이의 추가적인 증가에 의한 효과를 알아보았다. 해석결과, 파괴형태는 선단파괴 또는 사면내 파괴로 나타났으며 안정성을 확보한 상태에서는 한계평형해석결과와 동일하게 보강길이의 추가적인 증가에 의한 안정성 증대효과는 미미한 것으로 나타났다.

  • PDF