• Title/Summary/Keyword: slide

Search Result 982, Processing Time 0.027 seconds

Resistance of Biofilm Bacteria to Chlorination (생물막 세균의 염소소독제에 대한 내성)

  • 조재창;박성주;김상종
    • Korean Journal of Microbiology
    • /
    • v.31 no.3
    • /
    • pp.255-260
    • /
    • 1993
  • The Enterobacter cloacae biofilms developed on slide glasses and galvanized-iron coupons were applied to test the attached bacterial resistance to chlorination. The chlorine resistances of biofilm bacteria grown on the slide glasses and galvanized-iron coupons were 14 and 480 times that of the suspended bacteria, respectively. The chlorine resistance of particleattached bacterial populations was 48 times that of suspended bacterial populations. The biofilm bacterial densities developed on the slide glasses and galvanized-iron coupons which were immersed in the flowing tap water for 75 days were $4.75 {\times} 10^{4}$ and $1.12 {\times} 10^5 cfu/cm^{2}$ It is concluded that main mechanisms of enteric or HPC bacterial resistance to chlorination in tap waters are bacterial attachment or . adsorption to particles or bacterial aggregations and formation of biofilms on the inner wall of distribution systems by escaped bacteria from chlorination in water treatment processes, which results in bacterial regrowth in water distribution systems.

  • PDF

Hand Gesture Classification Using Multiple Doppler Radar and Machine Learning (다중 도플러 레이다와 머신러닝을 이용한 손동작 인식)

  • Baik, Kyung-Jin;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.33-41
    • /
    • 2017
  • This paper suggests a hand gesture recognition technology to control smart devices using multiple Doppler radars and a support vector machine(SVM), which is one of the machine learning algorithms. Whereas single Doppler radar can recognize only simple hand gestures, multiple Doppler radar can recognize various and complex hand gestures by using various Doppler patterns as a function of time and each device. In addition, machine learning technology can enhance recognition accuracy. In order to determine the feasibility of the suggested technology, we implemented a test-bed using two Doppler radars, NI DAQ USB-6008, and MATLAB. Using this test-bed, we can successfully classify four hand gestures, which are Push, Pull, Right Slide, and Left Slide. Applying SVM machine learning algorithm, it was confirmed the high accuracy of the hand gesture recognition.

Development of Error Compensation System and On the Machine Measurement System for Ultra-Precision Machine (초정밀가공기용 오차보상시스템 및 기상측정장치 개발)

  • 이대희;나혁민;오창진;김호상;민흥기;김민기;임경진;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.599-603
    • /
    • 2003
  • This paper present an error compensation system and On-Machine Measurement(OMM) system for improving the machining accuracy of ultra-precision lathe. The Fast-Tool-Servo(FTS) driven by a piezoelectric actuator is applied for error compensation system. The controller is implemented on the 32bit DSP for feedback control of piezoelectric actuator. The control system is designed to compensates three kinds of machining errors such as the straightness error of X-axis slide, the thermal growth error of the spindle. and the squareness between spindle and X-axis slide. OMM is preposed to measure the finished profile of workpiece on the machine-tool using capacitive sensor with highly accurate ruby tip probe guided by air bearing. The data acquisition system is linked to the CNC controller to get the position of each axis in real-time. Through the experiments, it is founded that the thermal growth of spindle and tile squareness error between spindle and X-axis slide influenced to machining error more than straightness error of X-axis slide in small travel length. These errors were simulated as a sinusoidal signal which has very low frequency and the FTS could compensate the signal less than 30 m. The implemented OMM system has been tested by measuring flat surface of 50 mm diameter and shows measurement error less than 400 mm

  • PDF

Analysis of Patellar Tracking and Q-angle During Semi-Squat Exercises (반 쪼그려 앉기(Semi-Squat) 운동 시 무릎뼈 주행(Tracking)과 Q-각도 분석)

  • Park, Seung-Kyu;Yang, Dae-Jung;Park, Jae-Man;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Closed kinematic chain exercises such as squatting have been widely indicated for knee rehabilitation in patients with patellofemoral disorders such as osteoarthritis and patellofemoral pain. Patellofemoral disorders are thought to be associated with abnormal patellar kinematics. In addition, the Q-angle may be undervalued in patients with patellofemoral pain and a laterally displaced patella. The purpose of this study was to assess patellar kinematics and the Q-angle during double-leg semi-squat and wall-slide semi-squat exercises. In this study, 28 asymptomatic subjects(16 male, 12 female) were assessed. Patellar tilt, patellar spin, and Q-angle were recorded using a motion analysis system during double-leg semi-squat and wall-slide semi-squat exercises. The Q-angle and patellar tilt were significantly increased, whereas patellar spin was significantly decreased, at $45^{\circ}$ of knee flexion compared with $0^{\circ}$. No differences were observed for the Q-angle, patellar tilt, and patellar spin during double-leg semi-squat and wall-slide semi-squat exercises. However, a significant interaction was observed between squat type and knee angle for patellar spin. We found that the patella is laterally tilted during semi-squat exercises and that there was no difference in patellar tracking between knee flexion during double-leg semi-squat and wall-slide semi-squat exercises.

In Situ PCR on the Glass Slide Using the Conventional DNA Thermal Cycler (기존의 핵산증폭기를 사용한 유리슬라이드상에서의 원위치 중합효소 연쇄반응)

  • 오정균;장진수;이재영
    • Korean Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.197-200
    • /
    • 2003
  • In order to establish effective in situ PCR on the glass slide using the conventional DNA thermal cycler, several parameters should be considered. These include full accessibility of PCR reagents into the cells, prevention of diffusing PCR products out of the cells, loss of PCR reagents by nonspecific adherence onto the glass slide, dryness of PCR reagents by heat, and heat conductivity from the heat block to the glass slide. Especially, to guarantee the full accessibility of PCR reagents to sample, relatively higher concentration of PCR reagents (particularly 4.5 mM of $Mg^{++}$) was required while 5 to 10 units/50 ${\mu}l$ reaction of Taq enzyme was enough as long as the step of pre-PCR incubation was included. Dryness of sample was prevented by addition of distilled water into the empty slots in the heat block, thereby providing the reproducible temperature-time profile of PCR. Observed temperature was lower than the programmed temperature by 3 to $4^{\circ}C$.

Modeling of the friction in the tool-workpiece system in diamond burnishing process

  • Maximov, J.T.;Anchev, A.P.;Duncheva, G.V.
    • Coupled systems mechanics
    • /
    • v.4 no.4
    • /
    • pp.279-295
    • /
    • 2015
  • The article presents a theoretical-experimental approach developed for modeling the coefficient of sliding friction in the dynamic system tool-workpiece in slide diamond burnishing of low-alloy unhardened steels. The experimental setup, implemented on conventional lathe, includes a specially designed device, with a straight cantilever beam as body. The beam is simultaneously loaded by bending (from transverse slide friction force) and compression (from longitudinal burnishing force), which is a reason for geometrical nonlinearity. A method, based on the idea of separation of the variables (time and metric) before establishing the differential equation of motion, has been applied for dynamic modeling of the beam elastic curve. Between the longitudinal (burnishing force) and transverse (slide friction force) forces exists a correlation defined by Coulomb's law of sliding friction. On this basis, an analytical relationship between the beam deflection and the sought friction coefficient has been obtained. In order to measure the deflection of the beam, strain gauges connected in a "full bridge" type of circuit are used. A flexible adhesive is selected, which provides an opportunity for dynamic measurements through the constructed measuring system. The signal is proportional to the beam deflection and is fed to the analog input of USB DAQ board, from where the signal enters in a purposely created virtual instrument which is developed by means of Labview. The basic characteristic of the virtual instrument is the ability to record and visualize in a real time the measured deflection. The signal sampling frequency is chosen in accordance with Nyquist-Shannon sampling theorem. In order to obtain a regression model of the friction coefficient with the participation of the diamond burnishing process parameters, an experimental design with 55 experimental points is synthesized. A regression analysis and analysis of variance have been carried out. The influence of the factors on the friction coefficient is established using sections of the hyper-surface of the friction coefficient model with the hyper-planes.

EMG effects of abdominal muscle on multiple forms of exercise (여러 형태의 복부 운동에 대한 복근의 EMG 효과)

  • Yoon, Wan-Young;Cho, Seok-Cheol
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.309-313
    • /
    • 2019
  • This study examined the response of the EMG of URA, LRA, IO, EO and RFM of various types of abdominal motion (crunch, spine V-up on ball, prone V-up on slide board, prone V-up on TRX, and prone V-up power wheel). The subjects performed anisometric contact of abs during these exercises. Tests have shown that there were no statistically significant differences between EO, URA and LRA between any movements. However, during the inspection of IO, the positive-wawed V-up motion showed significantly greater muscle activity than during the slide movement. Also, EMG activity during crunch was significantly lower than any other five exercises. These results indicate that in the implementation of equilateral absolutism, the equipment-free based exercise gives an impetus similar to equipment-based exercise. Abdominal muscle tissue is considered one of the five components that make up an individual's core. The abdominal muscles also ensure proper functioning of the lumbar spine. Although all abdominal muscles contribute to lumbar stabilization, TA & IO has been shown to perform major stabilizers.

Seismic responses of a free-standing two-story steel moment frame equipped with a cast iron-mortar sliding base

  • Chung, Yu-Lin;Kuo, Kuan-Ting;Nagae, Takuya;Kajiwara, Koichi
    • Earthquakes and Structures
    • /
    • v.17 no.3
    • /
    • pp.245-256
    • /
    • 2019
  • An experimental study was conducted to evaluate the dynamic behavior of a free-standing frame equipped with a movable base system using cast iron and mortar as the bearing materials. The preliminary friction test indicated that a graphite layer developed on the interface and exhibited stable friction behavior. The friction coefficient ranged from 0.33 to 0.36 when the applied normal compression stress ranged from 2.6 to 5.2 MPa. The effect of the variation of normal compression stress would be small. Shaking table tests on the free-standing frame showed that rock, slide, and rock-slide responses occurred. The cumulative slide distance reached 381 mm under JMA Kobe wave excitation; however, only a few cyclic slides occurred at the same locations along the moving track. Most surfaces sustained single slides. Similar results can be observed in other shaking conditions. The insufficient cyclic sliding and significant rocking resulted in a few graphite layers on the mortar surfaces. Friction coefficients were generally similar to those obtained in the preliminary friction tests; however, the values fluctuated when the rocking became significant. The collisions due to rocking caused strong horizontal acceleration responses and resulted in high friction coefficient. In addition, the strong horizontal acceleration responses caused by the collisions made the freestanding specimen unable to reduce the input horizontal acceleration notably, even when slippage occurred. Compared with the counterpart fixed-base specimen, the specimen equipped with the iron-mortar base could reduce the horizontal acceleration amplification response and the structural deformation, whereas the vertical acceleration response was doubled due to collisions from rocking.

Comparisons of Shoulder Muscle Activity and Muscle Activity Ratio during Serratus Anterior Exercise between CrossFit Practitioners with/without Shoulder Impingement Syndrome

  • Eunji Kang;Chaegil Lim;Hyoungwon Lim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.167-176
    • /
    • 2023
  • Purpose: Due to the high incidence of shoulder injuries, including shoulder impingement syndrome (SIS), among CrossFit practitioners due to frequent overhead movements, serratus anterior exercises are considered crucial for scapular stabilization in both intervention and prevention. Objective: The objective of this study is to compare the muscle activity and ratios of scapular stabilizing and shoulder girdle muscles between individuals with and without SIS during serratus punch and wall slide exercises, both targeting the serratus anterior muscle, in CrossFit training practitioners. Methods: Surface electromyography was used to compare the muscle activity and activity ratio of scapular stabilizing muscles and shoulder muscles during serratus punch and wall slide exercises in two groups of 20 CrossFit practitioners: ten with SIS and ten without symptoms. Results: The group with SIS showed higher activation of the pectoralis major, upper trapezius, and a higher pectoralis major/serratus anterior and upper trapezius/serratus anterior muscle activation ratio during the serratus punch exercise compared to the group without SIS. Similarly, during the wall slide exercise, the group with SIS exhibited higher activation of the upper trapezius and a higher upper trapezius/serratus anterior muscle activation ratio compared to the group without SIS. However, no significant difference in serratus anterior muscle activation was observed between the two groups. Conclusions: This study highlights the higher activation of the pectoralis major and upper trapezius muscles in CrossFit practitioners with SIS during the serratus anterior exercise, suggesting the importance of minimizing the overactivation of these muscles to prevent impingement syndrome in this population.

Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry (회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정)

  • Lee, Cha-Bum;Kim, Gyu-Ha;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.