Parameters Affecting India Ink Artifacts on Opposed-Phase MR Images

  • Kim, Bo Ra;Ha, Dong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.341-350
    • /
    • 2019
  • Purpose: To determine the MR parameters affecting India ink artifacts on opposed-phase chemical shift magnetic resonance (MR) imaging. Materials and Methods: The use of a female Sprague-Dawley rat was approved by our Institutional Animal Care and Use Committee. Using an iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) images, which is a modified Dixon method, axial opposed-phase images of the abdominal cavity were obtained with different MR parameters: series 1, different repetition times (TRs; 400, 2000, and 4000 ms); series 2, different echo times (TEs; 10, 50, and 100 ms); series 3, different field of views (FOVs; 6, 8, 16, and 24 cm); series 4, different echo train lengths (ETLs; 2, 4, and 8); series 5, different bandwidths (25, 50, and 85); and series 6, different slice thicknesses (1, 2, 4, 8, and 16 mm). Artifacts on opposed images obtained with different parameters were compared subjectively by two radiologists. For objective analysis, the thickness of the artifact was measured. Spearman's correlation between altered MR parameters and thicknesses of India ink artifact was obtained via objective analysis. Results: India ink artifact was increasingly apparent using shorter TE, larger FOV and ETL, and thicker slices upon subjective analysis. The objective analysis revealed a strong negative correlation between the thickness of the artifact and TE (r = -0.870, P < 0.01); however, strong positive correlations were found between FOV (r = 0.854, P < 0.01) and slice thickness (r = 0.971, P < 0.01). Conclusion: India ink artifact was thicker with shorter TE, larger FOV, and larger slice thickness.

뇌종양 확산강조영상에서 High B-value의 유용성 평가 (Usefulness of the High B-value DWI in Brain Tumors)

  • 김진태;변재후;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

격병구(隔餠灸)(부자구(附子灸),호초구(胡椒灸))의 연소특성(燃燒特性)에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Study on the Characteristics of Combustion in Indirect Moxibustion with Cake Insulation)

  • 이건휘;이건목;국우석
    • Journal of Acupuncture Research
    • /
    • 제21권6호
    • /
    • pp.233-248
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with monkshood cake, slice & black pepper cake. objectively, to be used as the quantitative data through the measurement of temperatqre, and to grasp the thermodynamic characteristics of moxibustion with monkshood cake, slice & black pepper cake. Methods : We have selected of the moxibustion with monkshood cake, slice & black pepper cake. indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with monkshood cake, slice & black pepper cake. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results & Conclusions : 1. We can design the moxibustion with monkshood cake that it has thermodynamic characteristics of 173sec effective combustion time, $44^{\circ}C$ maximum temperature, $0.22^{\circ}C/sec$ ascending maximum temperature, if we use 3mm thickness or 3mm and below of monkshood cake and the moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^3$. 2. We can design the moxibustion with monkshood cake that it has thermodynamic characteristics of 205~271sec effective combustion period time, $44.6{\sim}46.1^{\circ}C$ maximum temperature, $0.18{\sim}0.24^{\circ}C/sec$ ascending maximum temperature, if we use 3mm thickness of monkshood cake and the moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $480{\sim}720mg/cm^3$.

  • PDF

금속조형법을 위한 실시간 형상 모델링과 VRML 응용에 관한 연구

  • 정영대;최홍태;이석희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.321-326
    • /
    • 1997
  • This paper present how VRML file format can be used for RP Technology. VRML standards provids compact and powerful interface between remote RP manufacturer in network independent environment. We have constructed integrated and network-connected server system which can share the CAD data and varios process which is STL-to-VRML translater,slicing process,slice anchor process etc. This Server system consisted in file converter between STL and VRML,CGI system which sends a generated data to VRML client or browser, slice-generator which can re-slice at varied thickness and simulator which can show and check simultaneously status between near slices with support. This system aims to the integrated simulator which supports graphic animator and FEA analysis system.

Analysis of cladding failure in a BWR fuel rod using a SLICE-DO model of the FALCON code

  • Khvostov, G.
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2887-2900
    • /
    • 2020
  • Cladding failure in a fuel rod during operation in a BWR is analyzed using a FALCON code-based model. Comparative calculation with a neighbouring, intact rod is presented, as well. A considerable 'hot spot' effect in cladding temperature is predicted with the SLICE-DO model due to a thermal barrier caused by the localized crud deposition. Particularly significant overheating is expected to occur on the affected side of the cladding of the failed rod, in agreement with signs of significant localized crud deposition as revealed by Post Irradiation Examination. Different possibilities (criteria) are checked, and Pellet-Cladding Mechanical Interaction (PCMI) is shown to be one of the plausible potential threats. It is shown that PCMI could lead to discernible concentrated inelastic deformation in the overheated part of the cladding. None of the specific mechanisms considered can be experimentally or analytically identified as an only cause of the rod failure. However, according to the current calculation, a possibility of cladding failure by PCMI cannot be excluded if the crud thickness exceeded 300 ㎛.

마늘뜸의 연소특성에 관한 연구 (Experimental Study on the Characteristics of Combustion in Indirect Moxibustion with Garlic)

  • 이건목;이건휘;조남근;박소영
    • Journal of Acupuncture Research
    • /
    • 제21권4호
    • /
    • pp.31-51
    • /
    • 2004
  • Objective: The propose of this study is to investigate the characteristics of combustion in indirect moxibustion with garlic. Methods: We observed the characteristics of combustion by the variations of the thickness(3mm, 4mm, 5mm) of a slice for indirect moxibustion with garlic and mass(80mg, 100mg, 120mg) of moxa cone and existence of holes. The temperature of indirect moxibustion for garlic insulation with holes was higher than temperature of indirect moxibustion for garlic insulation without holes. Combustions time in the preheating period is about 1 minute, it varies by the existence of holes, the thickness of a slice for indirect moxibustion with garlic, and the density of moxa cone. Results: Maximum temperature of heating period was $38.7{\sim}46.2^{\circ}C$, combustion time in the heating period was 118~164sec and maximum ascending temperature gradient was $0.102{\sim}0.264^{\circ}C/sec$. Retaining period was shorter than heating period and stimulus of heating retains more, because it is higher than body temperature. By this report, indirect moxibustion with garlic is more effective with holes and the appropriate thickness of a slice for indirect moxibustion with garlic is 3.5~4mm. It is appropriate that the diameter of moxa cone is 8mm and height of that is 10mm. With this condition, effective combustion period is 120sec, maximum temperature is $42{\sim}44^{\circ}C$, maximum ascending temperature gradient is $0.14{\sim}0.16^{\circ}C/sec$. It is necessary to study clinical correlations for more accurate quantitative standard.

  • PDF

Reliability of Coronary Artery Calcium Severity Assessment on Non-Electrocardiogram-Gated CT: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1034-1043
    • /
    • 2021
  • Objective: The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. Materials and Methods: PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. Results: A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89-0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79-0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. Conclusion: The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.

흉부 전산화 단층촬영을 이용한 혈흉의 정량분석 (Quantitative analysis of hemothorax by computed tomography)

  • 강청희
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술 (Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet)

  • 문치웅;김상태;이대근;임태환;노용만;조장희;이윤
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.55-66
    • /
    • 1994
  • 4.7T의 고자장 자기공명 영상(Magnetic Resonance imaging : MRI) 장치에서 Tailored RF 경사자계반향(Tailored RF Gradient-Echo : TRGE)기법을 이용하여 phantom 영상과 고양이 뇌의 정맥혈관 영상을 얻었다. 증류수에 MgCl$_2$를 섞어 T1을 짧게한 지름 6cm의 원통형 phantom으로 TRGE기법에 대한 검증을 먼저 하였다. 이후 halothane으로 전신 마취된 몸무게 3.0~4.0kg의 고양이 뇌로부터 얻은 시단면(sagittal slice) 영상에서 Dorsal sagittal sinus, Straight sinus, Vein of corpus callosum과 Internal cerebral vein등의 혈관이 강조되어 나타남을 고양이 뇌의 해부학적 그림과 비교해 보였다. Tailored RF 파형은 ASPECT 3000 computer(스위스 BRUKER사 제품)의 PASCAL 언어를 이용하여 제작하였다. 사각형의 절편모양(slice profile)과 원하는 절편의 두께(slice thickness)에 선택절편내에서 절편방향으로 위상분포가 최대 2$\pi$가 되는 bi-linear ramp 모양을 갖는 절편함수를 공간상에서 Fourier 변환시켜 Tailored RF를 만들었다. TR/TE=205/10 msec, 절편두께 TH=7mm, 화소배열수(matrix size)=256$\times$256, 평면해상도(in-plane resolution)=0.62$\times$0.31mm$^2$, 관심영역 크기(field of view : FOV)=8cm의 영상조건으로 자기공명 TRGE 영상을 얻었다.

  • PDF