• Title/Summary/Keyword: slice

Search Result 985, Processing Time 0.028 seconds

A Study on the Program Slicing Model (Program Slice 생성 모형에 관한 연구)

  • Yun Chang-Byeon;Cha Yeong-Heon;Jeong Chang-Mo
    • Journal of the military operations research society of Korea
    • /
    • v.13 no.2
    • /
    • pp.42-52
    • /
    • 1987
  • Many programmers start debugging by reading the faulty program from start to bottom without investigating carefully the erroneous program. Expert programmers, however, trace backward from a particular variable in a specific statement to identify all possible sources of influence on the value of variable (program slice). Weiser proposed a slicing algorithm (method) that is complex, iterative and still in modification [3,4]. This paper presents a method to generate a program slice by use of matrix computation which represents all possible slices of the program. The matrix representation of a program is soundly based on the graph theory of data dependency.

  • PDF

Static Slicing of First-Order Functional Language based on Operational Semantics (오퍼레이셔널 의미에 기반한 일차 함수형 언어의 정적 분할)

  • Ahn, Joon-Seon;Han, Tai-Sook
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.877-885
    • /
    • 2000
  • Static slice means a set of parts of a program that potentially affect the values computed at a slicing criterion considering all the possible input values. In this paper, we have formally defined static slice of a first-order functional language based on operational semantics. And, we have presented a sound method to analyze static slice using abstract interpretation.

  • PDF

Analysis of cladding failure in a BWR fuel rod using a SLICE-DO model of the FALCON code

  • Khvostov, G.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2887-2900
    • /
    • 2020
  • Cladding failure in a fuel rod during operation in a BWR is analyzed using a FALCON code-based model. Comparative calculation with a neighbouring, intact rod is presented, as well. A considerable 'hot spot' effect in cladding temperature is predicted with the SLICE-DO model due to a thermal barrier caused by the localized crud deposition. Particularly significant overheating is expected to occur on the affected side of the cladding of the failed rod, in agreement with signs of significant localized crud deposition as revealed by Post Irradiation Examination. Different possibilities (criteria) are checked, and Pellet-Cladding Mechanical Interaction (PCMI) is shown to be one of the plausible potential threats. It is shown that PCMI could lead to discernible concentrated inelastic deformation in the overheated part of the cladding. None of the specific mechanisms considered can be experimentally or analytically identified as an only cause of the rod failure. However, according to the current calculation, a possibility of cladding failure by PCMI cannot be excluded if the crud thickness exceeded 300 ㎛.

Research On Solutions To Slicing Errors In FDM 3D Printing Of Thin-walled Structures

  • QINGYUAN ZHANG;Byung-Chun Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.176-181
    • /
    • 2024
  • The desktop-level 3D printing machines makes it easier for independent designers to produce collectible models. Desktop 3D printers that use FDM (Fused Deposition Modeling) technology usually use a minimum nozzle diameter of 0.4mm. When using FDM printers to make Gunpla models, Thin slice structures are prone to slicing errors, which lead to deformation of printed objects and reduction in structural strength. This paper aims to analyze the printing model that produces errors, control a single variable among the three variables of slice layer height, slice wall thickness and filament type for comparative testing, and find a way to avoid gaps. To provide assistance for using FDM printers to build models containing thin-walled structures.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

A Study of Disposition of Archaeological Remains in Wolseong Fortress of Gyeongju : Using Ground Penetration Radar(GPR) (GPR탐사를 통해 본 경주 월성의 유적 분포 현황 연구)

  • Oh, Hyun Dok;Shin, Jong Woo
    • Korean Journal of Heritage: History & Science
    • /
    • v.43 no.3
    • /
    • pp.306-333
    • /
    • 2010
  • Previous studies on Wolseong fortress have focused on capital system of Silla Dynasty and on the recreation of Wolseong fortress due to the excavations in and around Wolseong moat. Since the report on the Geographical Survey of Wolseong fortress was published and GPR survey in Wolseong fortress was executed as a trial test in 2004, the academic interest in the site has now expanded to the inside of the fortress. From such context, the preliminary research on the fortress including geophysical survey had been commenced. GPR survey had been conducted for a year from March, 2007. The principal purpose of the recent 3D GPR survey was to provide visualization of subsurface images of the entire Wolseong fortress area. In order to obtain 3D GPR data, dense profile lines were laid in grid-form. The total area surveyed was $112,535m^2$. Depth slice was applied to analyse each level to examine how the layers of the remains had changed and overlapped over time. In addition, slice overlay analysis methodology was used to gather reflects of each depth on a single map. Isolated surface visualization, which is one of 3D analysis methods, was also employed to gain more in-depth understanding and more accurate interpretations of the remain The GPR survey has confirmed that there are building sites whose archaeological features can be classified into 14 different groups. Three interesting areas with huge public building arrangement have been found in Zone 2 in the far west, Zone 9 in the middle, and Zone 14 in the far east. It is recognized that such areas must had been used for important public functions. This research has displayed that 3D GPR survey can be effective for a vast area of archaeological remains and that slice overlay images can provide clearer image with high contrast for objects and remains buried the site.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Parallelization Method of Slice-based video CODEC (슬라이스 기반 비디오 코덱 병렬화 기법)

  • Nam, Jung-Hak;Ji, Bong-Il;Jo, Hyun-Ho;Sim, Dong-Gyu;Cho, Dae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.48-56
    • /
    • 2010
  • Recently, we need to dramatically speed up real-time video encoding and decoding on mobile devices because complexity of video CODEC is significantly increasing along with the demand for multimedia service of high-quality and high-definition videos by users. A variety of research is conducted for parallelism of video processing using newly developed multi-core platforms. In this paper, we propose a method of parallelism based on slice partition of video compression CODEC. We propose a novel concept of a parallel slice for parallelism and propose a new coding order to be adequate to the parallel slice which keeps high coding efficiency. To minimize synchronization time of multiple parallel slices, we also propose a synchronization method to determinate whether the parallel slice could be independently decoded or not. Experimental results shows that we achieved 27.5% (40.7%) speed-up by parallelism with bit-rate increase of 3.4% (2.7%) for CIF sequences (720p sequences) by implementing the proposed algorithm on the H.264/AVC.

The Influence of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of 64-slice Multidetector Cardiac CT in Coronary Artery Disease (심박동수 및 관상동맥 석회화가 64 절편 다중검출기 심장 CT의 관상동맥 질환 진단일치도에 미치는 영향)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.339-347
    • /
    • 2009
  • Purpose : This study was to investigate the influence of heart rate and coronary calcification on diagnostic accuracy of 64-slice multidetector CT(MDCT) in coronary artery disease. Methods : 178 patients(84 men, 94 women) undergoing cardiac CT were included in this study. 3 coronary arteries(LAD, LCX, RCA) were assessed the presence of significant stenosis($\geq50%$) and the results compared with those of coronary angiography. Results : On a patient-based analysis, the diagnostic accuracy of 64-slice MDCT was 96.6%. The diagnostic accuracy on left anterior descending, left circumflex, right coronary artery were 86.5%, 84.3%, 92.1% respectively. Body mass index and blood pressure were not influenced on diagnostic accuracy of 64-slice MDCT. In less than 60/min of heart rate, accuracy was 90.1% and $\kappa$ value was 0.78. While in more than 70/min of heart rate, accuracy was 75.8% and $\kappa$ value was 0.52. In less than 100 of coronary calcification, accuracy was 91.3% and $\kappa$ value was 0.81. While in more than 400, accuracy was 68.6% and $\kappa$ value was 0.33. Conclusion : 64-slice MDCT shows similar diagnostic accuracy as coronary angiography. But in the context of more than 70/min of heart rate and 400 of coronary calcification, diagnostic accuracy was decreased. So there needs to identify heart rate and coronary calcification in cardiac CT, and if heart rate shows more than 70/min, use beta-blocker to regulate it.

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF