• 제목/요약/키워드: slant shear test

검색결과 5건 처리시간 0.023초

Bond behaviour at concrete-concrete interface with quantitative roughness tooth

  • Ayinde, Olawale O.;Wu, Erjun;Zhou, Guangdong
    • Advances in concrete construction
    • /
    • 제13권3호
    • /
    • pp.265-279
    • /
    • 2022
  • The roughness of substrate concrete interfaces before new concrete placement has a major effect on the interface bond behaviour. However, there are challenges associated with the consistency of the final roughness interface prepared using conventional roughness preparation methods which influences the interface bond performance. In this study, five quantitative interface roughness textures with different roughness tooth angles, depths, and tooth distribution were created to ensure consistency of interface roughness and to evaluate the bond behaviour at a precast and new concrete interface using the splitting tensile test, slant shear test, and double-shear test. In addition, smooth interface specimens and two separate the pitting interface roughness were also utilized. Obtained results indicate that the quantitative roughness has a very limited effect on the interface tensile bond strength if no extra micro-roughness or bonding agent is added at the interface. The roughness method however causes enhanced shear bond strength at the interface. Increased tooth depth improved both the tensile and shear bond strength of the interfaces, while the tooth distribution mainly influenced the shear bond strength. Major failure modes of the test specimens include interface failure, splitting cracks, and sliding failure, and are influenced by the tooth depth and tooth distribution. Furthermore, the interface properties were obtained and presented while a comparison between the different testing methods, in terms of bond strength, was performed.

초고성능 섬유보강 콘크리트로 보강된 콘크리트의 계면 전단강도 결정을 위한 경사전단 실험 (Slant Shear Test for Determining the Interfacial Shear Strength of Concrete Strengthened with Ultra-High Performance Fiber Reinforced Concrete)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제28권6호
    • /
    • pp.637-646
    • /
    • 2016
  • 이 연구에서는 강섬유 보강 초고성능 콘크리트(Ultra-high performance fiber reinforced concrete, 이하 UHPFRC)로 보강된 콘크리트 계면에서의 전단강도 평가를 위한 경사전단실험을 수행하였다. 실험변수는 면처리 유무와 콘크리트 강도, 그리고 UHPFRC의 강섬유 혼입률이다. 콘크리트의 계면은 숏블라스팅으로 면처리되었다. 실험결과, 숏블라스팅으로 면처리된 실험체의 계면 전단강도는 매끄러운 표면을 가진 실험체의 부착강도에 비해 매우 크게 나타났으며, 거친면을 만들기 위한 숏블라스팅 방법은 매우 효과적인 방법인 것으로 나타났다. 숏블라스팅으로 표면처리를 할 경우, 전단마찰 철근이 없더라도 콘크리트 계면에서 저항하는 전단강도는 현행 기준에서 제시하고 전단강도 상한값을 초과하는 것으로 나타났다. 기존의 콘크리트와 UHPFRC 사이의 전단마찰 설계는 전단마찰 철근의 유무와 상관없이 현행 콘크리트 구조기준을 사용해도 무방할 것으로 판단된다. 다만, 면처리를 하지 않은 경우에는 적절한 전단 보강재가 추가 설치하여야 할 것이다.

Elaboration and characterization of fiber-reinforced self-consolidating repair mortar containing natural perlite powder

  • Benyahia, A.;Ghrici, M.;Mansour, M. Said;Omran, A.
    • Advances in concrete construction
    • /
    • 제5권1호
    • /
    • pp.1-15
    • /
    • 2017
  • This research project aimed at evaluating experimentally the effect of natural perlite powder as an alternative supplementary cementing material (SCM) on the performance of fiber reinforced self-consolidating repair mortars (FR-SCRMs). For this purpose, four FR-SCRMs mixes incorporating 0%, 10%, 20%, and 30% of natural perlite powder as cement replacements were prepared. The evaluation was based on fresh (slump flow, flow time, and unit weight), hardened (air-dry unit weight, compressive and flexural strengths, dynamic modulus of elasticity), and durability (water absorption test) performances. The results reveal that structural repair mortars confronting the performance requirements of class R4 materials (European Standard EN 1504-3) could be designed using 10%, 20%, and 30% of perlite powder as cement substitutions. Bonding results between repair mortars containing perlite powder and old concrete substrate investigated by the slant shear test showed good interlocking justifying the effectiveness of these produced mortars.

콘크리트 균열 보수용 에폭시의 시공조건에 따른 성능 (Performance of Epoxy Resins for Repairing of Cracks in Concrete with Application Conditions)

  • 이찬영;심재원;김홍배
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.813-816
    • /
    • 2004
  • This study was performed to investigate bonding performance of epoxy resins for repairing of cracks in concrete, as a part of project to establish quality control standard for epoxy resins. In the slant shear strength test for hard and soft type epoxy, hard type was higher about 3 times than soft one. From the results, it is thought that hard type is suitable for load carrying. Injection of epoxy resin in the notch made flexural strength increase about $47\%$ over the specimen that epoxy resin is not injected. There were no differences in bonding performances with viscosity. Application of epoxy resin on the wet concrete surface made slant shear strength decrease about $46\%$, but similar performance to the case of application on the dry surface appeared by using epoxy resin for wet condition.

  • PDF

교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案) (Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay)

  • 김성환;김동호;김현오;이봉학
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF