• 제목/요약/키워드: skin capacitance

검색결과 38건 처리시간 0.018초

흡연이 십이원혈(十二原穴)의 체표 capacitance에 미치는 영향 (The Effects of Smoking on Bioelectrical Capacitance Measured at Twelve Source Points: A Cross-Over Study)

  • 김양섭;박영춘;임윤경
    • 대한한의학회지
    • /
    • 제36권3호
    • /
    • pp.35-52
    • /
    • 2015
  • Objectives: The objective of this study was to investigate the effects of smoking on the skin bio-electrical capacitance at twelve source points. Methods: Twenty healthy male subjects were assigned to smoking and sham-smoking by a random cross-over design. Skin bio-electrical capacitance was measured at twelve source points for 10 minutes before and after smoking. The change of skin bio-electrical capacitance was analysed. Results: 1. The skin bio-electrical capacitance at LU9, PC7 and LR3 was significantly increased after smoking. 2. In the smoking group, the skin bio-electrical capacitance at the source points of Hand Yin meridians significantly increased compared to that of Foot Yin and Hand Yang meridians. Conclusions: Smoking significantly increased the skin bio-electrical capacitance at the source points of Lung, Pericardium and Liver meridians. Hand Yin meridians appear to be more vulnerable to smoking than other meridians.

Effect of Enhancers on the Electrical Properties of Skin: The Effect of Azone and Ethanol

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권3호spc1호
    • /
    • pp.41-47
    • /
    • 1994
  • The effect of Azone and ethanol on the electrical properties of human and hairless mouse skin was studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from Nyquist plot. After the treatment of human-heat separated epidermis with Azone, contrary to the expectation, resistance increased about 60% and it did not change with time. Capacitance also increased; immediately after the treatment, it was about 110% of pretreatment value and it increased further with time. On the other hand, when hairless mouse skin was treated with Azone, marked changes occured; resistance fell almost to the value of bathing medium itself and capacitance increased to about 200% of its pretreatment value. Similar result were obtained when hairless mouse skin was treated with 100% ethanol. The results suggest that there are differences in the strength of barrier properties of stratum corneum (SC) between human and hairless mouse skin. Overall, the results provide further mechanistic insight into ion conduction through the skin and into the role of SC lipids in skin capacitance.

  • PDF

올레인산 및 프로필렌글리콜이 피부의 전기적 성질에 미치는 영향 (The Effect of Oleic Acid and Propylene Glycol on the Electrical Properties of Skin)

  • 오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권4호
    • /
    • pp.281-287
    • /
    • 1994
  • The effects of oleic acid, propylene glycol and 5% (w/w) oleic acid in propylene glycol on the electrical properties of hairless mouse skin were studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from the Nyquist plot. Immediately after the treatment with oleic acid, resistance was 145% of the pretreatment value. However it decreased with time and, after 20 hours, it was about 25% of its pretreatment value. Capacitance increased; immediately after the treatment, it was about 125% of pretreatment value and it seemed to increase slowly with time. When the skin was treated with propylene glycol, resistance decreased about 5O% and capacitance increased about 65%. Similar results were observed when the skin was treated with 5% (w/w) oleic acid in propylene glycol, except that the magnitude of resistance drop was much larger. Oleic acid acted synergistically with propylene glycol. Together with the flux data in the literature, the results obtained in this work indicate that electrical resistance is closely related to the permeability of drug molecules through the skin. The results are discussed in terms of the mechanism of action of these penetration enhancers. Overall, this work provided further mechanistic insight into the role of SC lipids in skin resistance and capacitance.

  • PDF

흡연이 수태음폐경 특정혈의 체표생체전하에 미치는 영향: 교차대조 연구 (The Effect of Smoking on the Bioelectrical Capacitance Measured at Specific Acupoints of Lung Meridian: A Cross-Over Study)

  • 김태민;이찬;이현진;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제31권2호
    • /
    • pp.90-97
    • /
    • 2014
  • Objective : The objective of this study is to investigate the effects of smoking on the skin bioelectrical capacitance at specific acupoints of lung meridian. Methods : Bioelectrical capacitance was measured on bilateral six source points(bilateral LU10, LU9, LU7, LU6, LU5, LU1), and the changes with time and between left and right side were analyzed. Results : The skin bioelectrical capacitance at specific acupoints of lung meridian was significantly increased after smoking. And it recovered as time passed. The change of the skin bioelectrical capacitances at specific acupoints of lung meridian with time were similar between left and right. Conclusion : Smoking increases the bioelectrical capacitance at specific acupoints of lung meridian. There is no difference between the effects of smoking on the bioelectrical capacitance at left and right specific acupoints of lung meridian.

Epidermal Capacitance를 이용한 시판되는 치료용 샴푸의 정상적인 개 피부에 대한 가수효과 (The Comparison of Shampoos for Skin Hydration by Measurement of Epidermal Capacitance in Normal Canine Skin)

  • Oh, Tae-Ho;Jae-Hoon heong;Jang, Kwang-Ho
    • 한국임상수의학회지
    • /
    • 제18권3호
    • /
    • pp.206-210
    • /
    • 2001
  • 피부질환에는 보조 치료로 다양한 치료용 샴푸가 빈번하게 적용되고 있으나 이들 샴푸의 피부수분에 미치는 영향은 일반적으로 평가되지 않고 있는 실정이다. 따라서 치료용 샴푸의 정확한 처방을 위해서는 피부의 수분을 측정하기 위한 측정법이 필요하다. 본 연구는 여러 종류의 치료용 샴푸의 피부 수분에 대한 영향을 알아보기 위해 Corneometer를 이용하여 피부에 샴푸를 적용후 수분을 측정하였다. 5두의 건강한 개를 대상으로 7가지 샴푸로 Humilac, Sebocalm, Sebolytics, Etiderm, Benzoyl peroxide, HyLyt, Zn-7 Derm를 선정하여 적용하였다. Humilac의 경우 통계학적으로 유의한 피부수분의 증가는 적용 후 17분(p<0.05), 77분(p<0.01)에 나타났으며, Benzoyl peroxide의 경우 적용 후 77분(p<0.05)에 피부의 수분이 유의하게 감소되었다. 다른 샴푸의 경우 통계학적으로 유의하지 않았으나 전반적으로 감소하는 경향을 보였으며 적용 후 77분에 최초 적용 수치에 근접하게 감소하였다. 어떤 샴푸도 피부에 부작용을 유발하지 않았다. Corneometer는 실제 임상에서 피부의 수분을 평가하는데 간단하고 유용한 측정방법을 사료된다.

  • PDF

다양한 제형을 활용한 화장수의 제조와 보습효과 (Formation of Skin Lotions Using Various Vehicles and Skin Hydration Effects for a Skin)

  • 조완구;김수정
    • 한국응용과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.124-131
    • /
    • 2009
  • We have produced, characterized and compared different colloidal vehicles based on nanoemulsions. We also have investigated morphology and droplet distribution by means of electron microscope and photon correlation spectroscopy. Nanoemulsion systems characterized by different method on formulations have been obtained. Hydration power has been studied by means of a corneometer, measuring the skin electrical capacitance before and after the application of various type of skin lotions. It has been demonstrated that nanoemulsion with oil or fatty alcohol displayed a pronounced hydration power with respect to the solubilization system. In order to compare the smoothness of the skin after using skin lotion, we have measured the friction force. The skin lotions produced by nanoemulsion technique show improved smoothness of an atopic skin.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • 제28권4호
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Sequential Tape Stripping에 따른 피부 Parameters의 변화에 관한 연구 (Changes in Skin Parameters after Sequential Tape Stripping)

  • 김승훈;김은주;남개원;안성연;이해광;문성준
    • 대한화장품학회지
    • /
    • 제33권2호
    • /
    • pp.99-104
    • /
    • 2007
  • 피부장벽 기능은 중요한 피부 기능 중 하나로 각질층과 표피층은 다른 피부층 보다 이러한 기능에 있어 큰 역할을 담당하고 있는 것으로 여겨지고 있다. 각질층은 표피 기저층에서부터 표피세포가 위층으로 올라오면서 분화의 과정을 거쳐 형성되게 된다. 이러한 분화 과정은 피부 표면에서 완성되게 되며 지속적으로 올라오는 새로운 각질로 대체되게 되어 건강한 방어막을 형성하게 된다. 본 연구는 tape stripping에 따른 깊이별 여러 인자들의 변화를 살펴봄으로써 각질층의 각 부분의 역할에 대해 살펴보고자 하였다. 피부 표면 수분량에 있어서는 각질층 중 위쪽에 위치하고 있는 uppermost stratum corneum (SC)가 중요한 역할을 하고 있는 것으로 나타났으며 수분증발을 막는 장벽으로써의 역할은 lower SC가 주로 역할을 하는 것으로 나타났다. 그리고 일반적으로 pH는 각질의 산성 pH에서 표피 쪽으로 진행하면서 중성의 pH가 보여지는 것으로 보고되고 있는데 각질층만을 살펴봤을 경우, 아래층으로 내려가면서 오히려 다소 산도가 높아짐을 관찰할 수 있었다. 또한 tape stripping을 통한 각질량 분석에서는 stripping을 거듭할수록 채취되는 각질량도 감소되는 양상을 보여주었다. 본 연구를 통해 수 ${\sim}$ 수십 층으로 구성되는 각질층 중 윗부분은 수분량에, 아래 부분은 장벽으로서의 기능에 있어 역할을 하고 있음을 알 수 있었고 각질층의 깊이가 증가할수록 pH와 각질량은 감소함을 알 수 있었다. 이러한 각질층 내의 위치 차이에 따른 역할에 대한 결과를 통해 화장품 개발에 있어서 다양한 접근이 가능할 것으로 기대되어진다. 또한 본 연구를 통해 각질층도 그 위치에 따라 다른 역할을 담당하고 있음을 간접적으로 알 수 있었고 향후 이러한 점에 초점을 맞춘 특화된 각질 연구도 필요할 것으로 생각되어진다.

1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정 (Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System)

  • 안지원;서은정;우영아;김효진
    • 약학회지
    • /
    • 제47권3호
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

콜라겐 펩타이드 및 GABA 복합물의 섭취가 피부 및 수면장애 개선에 미치는 영향 (Beneficial Effect of Collagen-Peptide Mixture with GABA on Improvement Skin and Sleep Quality)

  • 김정기;임성환;김완기;조창희;하재현;서대방
    • 대한화장품학회지
    • /
    • 제44권3호
    • /
    • pp.277-284
    • /
    • 2018
  • 콜라겐 펩타이드(collagen peptide)는 단백질의 가수 분해물로서 주름 완화, 보습력 증대, 탄력 개선 등의 특정 피부 효능을 나타낼 수 있어 화장품 혹은 피부 개선 기능식품으로서 활용되고 있다. ${\gamma}-aminobutyric$ acid (GABA)는 척추 동물의 뇌, 척수에 존재하는 신경전달 물질로서 수면의 질과 양을 개선해 준다고 알려져 있다. 본 연구에서는 콜라겐 펩타이드와 GABA의 복합물이 수면 장애가 있는 여성에게 8주 경구 섭취를 통해서 수면 및 피부 상태를 개선할 수 있는가에 관하여 확인하였다. 복합물(J85091900)은 8주간 연속적으로 섭취 시, 수면장애지수(PSQI)가 유의적으로 감소하였으며, 수면 시간을 7% 증가시켰다. 또한, 피부 거칠기, 눈가 주름 및 피부 수분량(capacitance)을 유의적으로 개선하였다. 이상의 결과에서 콜라겐과 GABA의 복합물은 복합 수면 장애에 따른 피부의 노화 현상으로부터 피부를 보호할 수 있음을 확인하여 먹는 화장품의 핵심 소재로 활용 가능함을 확인하였다.