The Effects of Smoking on Bioelectrical Capacitance Measured at Twelve Source Points: A Cross-Over Study (흡연이 십이원혈(十二原穴)의 체표 capacitance에 미치는 영향)

  • Kim, Yang-Seob;Park, Young-Chun;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.35-52
    • /
    • 2015
  • Objectives: The objective of this study was to investigate the effects of smoking on the skin bio-electrical capacitance at twelve source points. Methods: Twenty healthy male subjects were assigned to smoking and sham-smoking by a random cross-over design. Skin bio-electrical capacitance was measured at twelve source points for 10 minutes before and after smoking. The change of skin bio-electrical capacitance was analysed. Results: 1. The skin bio-electrical capacitance at LU9, PC7 and LR3 was significantly increased after smoking. 2. In the smoking group, the skin bio-electrical capacitance at the source points of Hand Yin meridians significantly increased compared to that of Foot Yin and Hand Yang meridians. Conclusions: Smoking significantly increased the skin bio-electrical capacitance at the source points of Lung, Pericardium and Liver meridians. Hand Yin meridians appear to be more vulnerable to smoking than other meridians.

Effect of Enhancers on the Electrical Properties of Skin: The Effect of Azone and Ethanol

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 1994
  • The effect of Azone and ethanol on the electrical properties of human and hairless mouse skin was studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from Nyquist plot. After the treatment of human-heat separated epidermis with Azone, contrary to the expectation, resistance increased about 60% and it did not change with time. Capacitance also increased; immediately after the treatment, it was about 110% of pretreatment value and it increased further with time. On the other hand, when hairless mouse skin was treated with Azone, marked changes occured; resistance fell almost to the value of bathing medium itself and capacitance increased to about 200% of its pretreatment value. Similar result were obtained when hairless mouse skin was treated with 100% ethanol. The results suggest that there are differences in the strength of barrier properties of stratum corneum (SC) between human and hairless mouse skin. Overall, the results provide further mechanistic insight into ion conduction through the skin and into the role of SC lipids in skin capacitance.

  • PDF

The Effect of Oleic Acid and Propylene Glycol on the Electrical Properties of Skin (올레인산 및 프로필렌글리콜이 피부의 전기적 성질에 미치는 영향)

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.4
    • /
    • pp.281-287
    • /
    • 1994
  • The effects of oleic acid, propylene glycol and 5% (w/w) oleic acid in propylene glycol on the electrical properties of hairless mouse skin were studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from the Nyquist plot. Immediately after the treatment with oleic acid, resistance was 145% of the pretreatment value. However it decreased with time and, after 20 hours, it was about 25% of its pretreatment value. Capacitance increased; immediately after the treatment, it was about 125% of pretreatment value and it seemed to increase slowly with time. When the skin was treated with propylene glycol, resistance decreased about 5O% and capacitance increased about 65%. Similar results were observed when the skin was treated with 5% (w/w) oleic acid in propylene glycol, except that the magnitude of resistance drop was much larger. Oleic acid acted synergistically with propylene glycol. Together with the flux data in the literature, the results obtained in this work indicate that electrical resistance is closely related to the permeability of drug molecules through the skin. The results are discussed in terms of the mechanism of action of these penetration enhancers. Overall, this work provided further mechanistic insight into the role of SC lipids in skin resistance and capacitance.

  • PDF

The Effect of Smoking on the Bioelectrical Capacitance Measured at Specific Acupoints of Lung Meridian: A Cross-Over Study (흡연이 수태음폐경 특정혈의 체표생체전하에 미치는 영향: 교차대조 연구)

  • Kim, Tae-Min;Lee, Chan;Lee, Hyun-Jin;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.90-97
    • /
    • 2014
  • Objective : The objective of this study is to investigate the effects of smoking on the skin bioelectrical capacitance at specific acupoints of lung meridian. Methods : Bioelectrical capacitance was measured on bilateral six source points(bilateral LU10, LU9, LU7, LU6, LU5, LU1), and the changes with time and between left and right side were analyzed. Results : The skin bioelectrical capacitance at specific acupoints of lung meridian was significantly increased after smoking. And it recovered as time passed. The change of the skin bioelectrical capacitances at specific acupoints of lung meridian with time were similar between left and right. Conclusion : Smoking increases the bioelectrical capacitance at specific acupoints of lung meridian. There is no difference between the effects of smoking on the bioelectrical capacitance at left and right specific acupoints of lung meridian.

The Comparison of Shampoos for Skin Hydration by Measurement of Epidermal Capacitance in Normal Canine Skin (Epidermal Capacitance를 이용한 시판되는 치료용 샴푸의 정상적인 개 피부에 대한 가수효과)

  • Oh, Tae-Ho;Jae-Hoon heong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.18 no.3
    • /
    • pp.206-210
    • /
    • 2001
  • Various commercial shampoos were frequently prescribed for dermatologic therapy in small animal practice. Skim hydration affected by the shampoos, however, was not evaluated routinely. In order to evaluate the skin hydration for the exact prescription of shampoos method to measure skin hydration of shampoos are needed. This study was undertaken to evaluate the skin hydration effect of shampoo on canine skin using Corneometer. Five healthy dogs were applied with 7 commercial shampoos: Humilac, Sebocalm, Sebolytics, Etiderm, Benzoyl peroxide, HyLyt and Zn-7 Derm. Skin hydrations were evaluated by measurement of electrical capacitance by Corneometer. A statistically significant increase in skim hydration was found 17(p<0.05) and 77 minutes(p<0.01) after application of Humilac indicating a humidifying effect of this product. A statistically significant decrease in skin hydration was found for the Benzoyl peroxide after 77 minutes(p<0.05). No statistically significant differences between the other shampoos were found. None of the products tested had any negative effect on the skin barrier function. The Corneometer was found useful for detecting skin hydration to shampoos and considered as a simple and useful tool for prescription of various shampoos routine practice.

  • PDF

Formation of Skin Lotions Using Various Vehicles and Skin Hydration Effects for a Skin (다양한 제형을 활용한 화장수의 제조와 보습효과)

  • Cho, Wan-Goo;Kim, Su-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.124-131
    • /
    • 2009
  • We have produced, characterized and compared different colloidal vehicles based on nanoemulsions. We also have investigated morphology and droplet distribution by means of electron microscope and photon correlation spectroscopy. Nanoemulsion systems characterized by different method on formulations have been obtained. Hydration power has been studied by means of a corneometer, measuring the skin electrical capacitance before and after the application of various type of skin lotions. It has been demonstrated that nanoemulsion with oil or fatty alcohol displayed a pronounced hydration power with respect to the solubilization system. In order to compare the smoothness of the skin after using skin lotion, we have measured the friction force. The skin lotions produced by nanoemulsion technique show improved smoothness of an atopic skin.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Changes in Skin Parameters after Sequential Tape Stripping (Sequential Tape Stripping에 따른 피부 Parameters의 변화에 관한 연구)

  • Kim, Seung-Hun;Kim, Eun-Joo;Nam, Gae-Won;Ahn, Sung-Yeon;Lee, Hae-Kwang;Moon, Seong-Joon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.2
    • /
    • pp.99-104
    • /
    • 2007
  • The skin barrier function is one of the vital functions. Horny layer and epidermis among various skin layers play an important role in protecting body from environmental insults. Stratum corneum is completely formed by differentiation processes from the basal layer and newly formed corneocytes push the older ones from skin surface. In this study we investigated changes of various parameters - capacitance, transepidermal water loss (TEWL), pH and amount of removed corneocytes - according to the stratum corneum's depth. We removed the stratum corneum using tape stripping technique. We found that uppermost stratum corneum play an important role in skin surface moisturization and lower stratum corneum in protecting transepidermal water loss. In addition, skin pH is more acidic than surface pH. In the stratum corneum, skin pH is mote acidic in the deeper layer. Furthermore amount of removed corneocyte is also decreased according to depth because of stronger cell-cell union strength. From these results we suggest that stratum corneum has different characteristics depending on their position.

Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System (1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정)

  • 안지원;서은정;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

Beneficial Effect of Collagen-Peptide Mixture with GABA on Improvement Skin and Sleep Quality (콜라겐 펩타이드 및 GABA 복합물의 섭취가 피부 및 수면장애 개선에 미치는 영향)

  • Kim, Jeong Kee;Lim, Seong Hwan;Kim, Wan Gi;Cho, Changhui;Ha, Jaehyoun;Seo, Dae Bang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.3
    • /
    • pp.277-284
    • /
    • 2018
  • Collagen peptide plays a protective role in skin by increasing the activity of antioxidant, acts like an activator of skin regeneration by positive feedback and is used as a potent candidate for cosmetics or functional food. GABA acts at inhibitory synapses in the brain by binding to specific transmembrane receptors of both pre- and postsynaptic neuronal processes in vertebrates, is also involved in the synthesis of melatonin and might exert regulatory effects on sleep and reproductive functions. In this study, we investigated the beneficial effect of a mixture of collagen peptide and GABA (J85091900) on skin and sleep condition in woman experiencing sleep disorder. We found that oral supplement with J85091900 significantly decreased the value of Pittsburgh Sleep Quality Index (PSQI), increased sleeping time by 7%, and also improved skin roughness (Ra, Rz, Rt), periorbital wrinkle (Ra, Rt), and skin capacitance in human. These findings indicate that dual strategy with which skin improvement is accomplished using collagen peptide and sleeping well is acquired using GABA could be the novel solution for sleeping beauty by edible cosmetics to improve skin status.