• Title/Summary/Keyword: size reduction

Search Result 3,636, Processing Time 0.036 seconds

Analysis on the Rainfall Triggered Slope Failure with a Variation of Soil Layer Thickness: Flume Tests (강우로 인한 조립토 사면에서의 토층 두께 변화에 따른 사면의 활동 분석: 실내 모형실험)

  • SaGong, Myung;Yoo, Jea-Ho;Lee, Sung-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.91-103
    • /
    • 2009
  • Slope failure depends upon the climatic features related to related rainfall, structural geology and geomorphological features as well as the variation of the mechanical behaviors of soil constituting a slope. In this paper, among many variables, effects of soil layer thickness on the slope failure process, and variations of matric suction and volumetric water content were observed. When the soil layer is relatively thick, the descending wetting front decreases matric suction and the observed matric suction reaches to "0" value. When the wetting front reaches to the impermeable boundary, the bottom surface of steel soil box, ascending wetting front was observed. This observation can be postulated to be the effects of various sizes of pores. When macro size pores exist, the capillary effects can be reduced and infilling of pore will be limited. The partially filled pores would be filled with water during the ascending of the wetting front, which bounces from the impermeable boundary. This assumption has been assured from the observation of variation of the volumetric water contents at different depth. When the soil layer is thick (thickness = 20 cm), for granular material, erosion is a cause triggering the slope failure. It has been found that the initiation of erosion occurs when the top soil is fully saturated. Meanwhile, when the soil layer is shallow (thickness = 10 cm), slope slides as en mass. The slope failure for this condition occurs when the wetting front reaches to the interface between the soil layer and steel soil box. As the wetting front approaches to the bottom of soil layer, reduction of shear resistance along the boundary and increase of the unit weight due to the infiltration occur and these produce complex effects on the slope failure processes.

Analysis of Pedigree Structure and Inbreeding Coefficient for Performance Tested Holstein Cows in Korea (우리나라 Holstein 능력검정 젖소 집단의 혈통구조 및 근교계수 분석)

  • Won, J.I.;Dang, C.G.;Lim, H.J.;Jung, Y.S.;Im, S.K.;Lee, J.K.;Kim, J.B.;Cho, M.R.;Min, H.L.;Yoon, H.B.
    • Journal of agriculture & life science
    • /
    • v.50 no.2
    • /
    • pp.107-116
    • /
    • 2016
  • The study was aimed to analyze pedigree structure and inbreeding coefficients for performance tested Holstein cows in Korea. A total of 400,029 Holstein cows data which born between 2002 and 2012 were obtained from Dairy Cattle Improvement Center of National Agricultural Cooperative Federation(NACF). Their related pedigrees, as obtained from Korean Animal Improvement Association(KAIA), consisted of 509,740 animals. Pedigree depth of the cows were traced back to 3 generations earlier. The percentage of cows with fully identified ancestors in various provinces of Korea were 55.18%(Gyeonggi-do), 23.49%(Gangwon-do), 47.83%(Chungcheongnam-do), 53.62%(Chungcheongbuk-do), 56.38%(Gyeongsangbuk-do), 51.35% (Gyeongsangnam-do), 26.58%(Jeollanam-do), 49.41%(Jeollabuk-do), and 56.90%(Jeju-do), whereas, it was about 63.20% as a whole in Korea. The average inbreeding coefficients showed increment across the consecutive years of birth such as, 0.43(2002), 0.44(2003), 0.58(2004), 0.64(2005), 0.78(2006), 0.93(2007), 1.08(2008), 1.23(2009), 1.46(2010), 1.77(2011), and 2.03 (2012). However, this coefficient was 0.93 in overall Korean population. An average generation interval for sire to daughter genetic path was 8.15 years; which was about 4.20 years considering dam to daughter genetic path. The estimated effective population sizes (Ne) were 56.5, 51.3, and 32.2 animals born in 2004, 2009, and 2012, respectively. These results indicated that an increased rate of inbreeding has led to a significant reduction in the Ne over the decade.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Region of Interest Extraction and Bilinear Interpolation Application for Preprocessing of Lipreading Systems (입 모양 인식 시스템 전처리를 위한 관심 영역 추출과 이중 선형 보간법 적용)

  • Jae Hyeok Han;Yong Ki Kim;Mi Hye Kim
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.4
    • /
    • pp.189-198
    • /
    • 2024
  • Lipreading is one of the important parts of speech recognition, and several studies have been conducted to improve the performance of lipreading in lipreading systems for speech recognition. Recent studies have used method to modify the model architecture of lipreading system to improve recognition performance. Unlike previous research that improve recognition performance by modifying model architecture, we aim to improve recognition performance without any change in model architecture. In order to improve the recognition performance without modifying the model architecture, we refer to the cues used in human lipreading and set other regions such as chin and cheeks as regions of interest along with the lip region, which is the existing region of interest of lipreading systems, and compare the recognition rate of each region of interest to propose the highest performing region of interest In addition, assuming that the difference in normalization results caused by the difference in interpolation method during the process of normalizing the size of the region of interest affects the recognition performance, we interpolate the same region of interest using nearest neighbor interpolation, bilinear interpolation, and bicubic interpolation, and compare the recognition rate of each interpolation method to propose the best performing interpolation method. Each region of interest was detected by training an object detection neural network, and dynamic time warping templates were generated by normalizing each region of interest, extracting and combining features, and mapping the dimensionality reduction of the combined features into a low-dimensional space. The recognition rate was evaluated by comparing the distance between the generated dynamic time warping templates and the data mapped to the low-dimensional space. In the comparison of regions of interest, the result of the region of interest containing only the lip region showed an average recognition rate of 97.36%, which is 3.44% higher than the average recognition rate of 93.92% in the previous study, and in the comparison of interpolation methods, the bilinear interpolation method performed 97.36%, which is 14.65% higher than the nearest neighbor interpolation method and 5.55% higher than the bicubic interpolation method. The code used in this study can be found a https://github.com/haraisi2/Lipreading-Systems.

Comparison of Inpatient Medical Use between Non-specialty and Specialty Hospitals: A Study Focused on Knee Replacement Arthroplasty (전문병원과 비전문병원 입원환자의 의료이용 비교 분석: 인공관절치환술(슬관절)을 대상으로)

  • Mi-Sung Kim;Hyoung-Sun Jeong;Ki-Bong Yoo;Je-Gu Kang;Han-Sol Jang;Kwang-Soo Lee
    • Health Policy and Management
    • /
    • v.34 no.1
    • /
    • pp.78-86
    • /
    • 2024
  • Background: The purpose of this study was to determine the effectiveness of the specialty hospital system by comparing the medical use of inpatients who had artificial joint replacement surgery in specialty hospitals and non-specialty hospitals. Methods: This study utilized 2021-2022 healthcare benefit claims data provided by the Health Insurance Review and Assessment Service. The dependent variable is inpatient medical use which is measured in terms of charges per case and length of stay. The independent variable was whether the hospital was designated as a specialty hospital, and the control variables were patient-level variables (age, gender, insurer type, surgery type, and Charlson comorbidity index) and medical institution-level variables (establishment type, classification, location, number of orthopedic surgeons, and number of nurses). Results: The results of the multiple regression analysis between charges per case and whether a hospital is designated as a specialty hospital showed a statistically significant negative relationship between charges per case and whether a hospital is designated as a specialty hospital. This suggests a significant low in charges per case when a hospital is designated as a specialty hospital compared to a non-specialty hospital, indicating that there is a difference in medical use outcomes between specialty hospitals and non-specialty hospitals inpatients. Conclusion: The practical implications of this study are as follows. First, the criteria for designating specialty hospitals should be alleviated. In our study, the results show that specialty hospitals have significantly lower per-case costs than non-specialty hospitals. Despite the cost-effectiveness of specialty hospitals, the high barriers to be designated for specialty hospitals have gathered the specialty hospitals in metropolitan and major cities. To address the regional imbalance of specialty hospitals, it is believed that ease the criteria for designating specialty hospitals in non-metropolitan areas, such as introducing "semi-specialty hospitals (tentative name)," will lead to a reduction in health disparities between regions and reduce medical costs. Second, it is necessary to determine the appropriateness of the size of hospitals' medical staff. The study found that the number of orthopedic surgeons and nurses varied in charges per case. Therefore, it is believed that appropriately allocating hospital medical staff can maximize the cost-effectiveness of medical services and ultimately reduce medical costs.

Optimum Radiotherapy Schedule for Uterine Cervical Cancer based-on the Detailed Information of Dose Fractionation and Radiotherapy Technique (처방선량 및 치료기법별 치료성적 분석 결과에 기반한 자궁경부암 환자의 최적 방사선치료 스케줄)

  • Cho, Jae-Ho;Kim, Hyun-Chang;Suh, Chang-Ok;Lee, Chang-Geol;Keum, Ki-Chang;Cho, Nam-Hoon;Lee, Ik-Jae;Shim, Su-Jung;Suh, Yang-Kwon;Seong, Jinsil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.143-156
    • /
    • 2005
  • Background: The best dose-fractionation regimen of the definitive radiotherapy for cervix cancer remains to be clearly determined. It seems to be partially attributed to the complexity of the affecting factors and the lack of detailed information on external and intra-cavitary fractionation. To find optimal practice guidelines, our experiences of the combination of external beam radiotherapy (EBRT) and high-dose-rate intracavitary brachytherapy (HDR-ICBT) were reviewed with detailed information of the various treatment parameters obtained from a large cohort of women treated homogeneously at a single institute. Materials and Methods: The subjects were 743 cervical cancer patients (Stage IB 198, IIA 77, IIB 364, IIIA 7, IIIB 89 and IVA 8) treated by radiotherapy alone, between 1990 and 1996. A total external beam radiotherapy (EBRT) dose of $23.4\~59.4$ Gy (Median 45.0) was delivered to the whole pelvis. High-dose-rate intracavitary brachytherapy (HDR-IBT) was also peformed using various fractionation schemes. A Midline block (MLB) was initiated after the delivery of $14.4\~43.2$ Gy (Median 36.0) of EBRT in 495 patients, while In the other 248 patients EBRT could not be used due to slow tumor regression or the huge initial bulk of tumor. The point A, actual bladder & rectal doses were individually assessed in all patients. The biologically effective dose (BED) to the tumor ($\alpha/\beta$=10) and late-responding tissues ($\alpha/\beta$=3) for both EBRT and HDR-ICBT were calculated. The total BED values to point A, the actual bladder and rectal reference points were the summation of the EBRT and HDR-ICBT. In addition to all the details on dose-fractionation, the other factors (i.e. the overall treatment time, physicians preference) that can affect the schedule of the definitive radiotherapy were also thoroughly analyzed. The association between MD-BED $Gy_3$ and the risk of complication was assessed using serial multiple logistic regression models. The associations between R-BED $Gy_3$ and rectal complications and between V-BED $Gy_3$ and bladder complications were assessed using multiple logistic regression models after adjustment for age, stage, tumor size and treatment duration. Serial Coxs proportional hazard regression models were used to estimate the relative risks of recurrence due to MD-BED $Gy_{10}$, and the treatment duration. Results: The overall complication rate for RTOG Grades $1\~4$ toxicities was $33.1\%$. The 5-year actuarial pelvic control rate for ail 743 patients was $83\%$. The midline cumulative BED dose, which is the sum of external midline BED and HDR-ICBT point A BED, ranged from 62.0 to 121.9 $Gy_{10}$ (median 93.0) for tumors and from 93.6 to 187.3 $Gy_3$ (median 137.6) for late responding tissues. The median cumulative values of actual rectal (R-BED $Gy_3$) and bladder Point BED (V-BED $Gy_3$) were 118.7 $Gy_3$ (range $48.8\~265.2$) and 126.1 $Gy_3$ (range: $54.9\~267.5$), respectively. MD-BED $Gy_3$ showed a good correlation with rectal (p=0.003), but not with bladder complications (p=0.095). R-BED $Gy_3$ had a very strong association (p=<0.0001), and was more predictive of rectal complications than A-BED $Gy_3$. B-BED $Gy_3$ also showed significance in the prediction of bladder complications in a trend test (p=0.0298). No statistically significant dose-response relationship for pelvic control was observed. The Sandwich and Continuous techniques, which differ according to when the ICR was inserted during the EBRT and due to the physicians preference, showed no differences in the local control and complication rates; there were also no differences in the 3 vs. 5 Gy fraction size of HDR-ICBT. Conclusion: The main reasons optimal dose-fractionation guidelines are not easily established is due to the absence of a dose-response relationship for tumor control as a result of the high-dose gradient of HDR-ICBT, individual differences In tumor responses to radiation therapy and the complexity of affecting factors. Therefore, in our opinion, there is a necessity for individualized tailored therapy, along with general guidelines, in the definitive radiation treatment for cervix cancer. This study also demonstrated the strong predictive value of actual rectal and bladder reference dosing therefore, vaginal gauze packing might be very Important. To maintain the BED dose to less than the threshold resulting in complication, early midline shielding, the HDR-ICBT total dose and fractional dose reduction should be considered.

Rapid Rural-Urban Migration and the Rural Economy in Korea (한국(韓國)의 급격(急激)한 이촌향도형(離村向都型) 인구이동(人口移動)과 농촌경제(農村經濟))

  • Lee, Bun-song
    • KDI Journal of Economic Policy
    • /
    • v.12 no.3
    • /
    • pp.27-45
    • /
    • 1990
  • Two opposing views prevail regarding the economic impact of rural out-migration on the rural areas of origin. The optimistic neoclassical view argues that rapid rural out-migration is not detrimental to the income and welfare of the rural areas of origin, whereas Lipton (1980) argues the opposite. We developed our own alternative model for rural to urban migration, appropriate for rapidly developing economies such as Korea's. This model, which adopts international trade theories of nontraded goods and Dutch Disease to rural to urban migration issues, argues that rural to urban migration is caused mainly by two factors: first, the unprofitability of farming, and second, the decrease in demand for rural nontraded goods and the increase in demand for urban nontraded goods. The unprofitability of farming is caused by the increase in rural wages, which is induced by increasing urban wages in booming urban manufacturing sectors, and by the fact that the cost increases in farming cannot be shifted to consumers, because farm prices are fixed worldwide and because the income demand elasticity for farm products is very low. The demand for nontraded goods decreases in rural and increases in urban areas because population density and income in urban areas increase sharply, while those in rural areas decrease sharply, due to rapid rural to urban migration. Given that the market structure for nontraded goods-namely, service sectors including educational and health facilities-is mostly in monopolistically competitive, and that the demand for nontraded goods comes only from local sources, the urban service sector enjoys economies of scale, and can thus offer services at cheaper prices and in greater variety, whereas the rural service sector cannot enjoy the advantages offered by scale economies. Our view concerning the economic impact of rural to urban migration on rural areas of origin agrees with Lipton's pessimistic view that rural out-migration is detrimental to the income and welfare of rural areas. However, our reasons for the reduction of rural income are different from those in Lipton's model. Lipton argued that rural income and welfare deteriorate mainly because of a shortage of human capital, younger workers and talent resulting from selective rural out-migration. Instead, we believe that rural income declines, first, because a rapid rural-urban migration creates a further shortage of farm labor supplies and increases rural wages, and thus reduces further the profitability of farming and, second, because a rapid rural-urban migration causes a further decline of the rural service sectors. Empirical tests of our major hypotheses using Korean census data from 1966, 1970, 1975, 1980 and 1985 support our own model much more than the neoclassical or Lipton's models. A kun (county) with a large out-migration had a smaller proportion of younger working aged people in the population, and a smaller proportion of highly educated workers. But the productivity of farm workers, measured in terms of fall crops (rice) purchased by the government per farmer or per hectare of irrigated land, did not decline despite the loss of these youths and of human capital. The kun having had a large out-migration had a larger proportion of the population in the farm sector and a smaller proportion in the service sector. The kun having had a large out-migration also had a lower income measured in terms of the proportion of households receiving welfare payments or the amount of provincial taxes paid per household. The lower incomes of these kuns might explain why the kuns that experienced a large out-migration had difficulty in mechanizing farming. Our policy suggestions based on the tests of the currently prevailing hypotheses are as follows: 1) The main cause of farming difficulties is not a lack of human capital, but the in­crease in production costs due to rural wage increases combined with depressed farm output prices. Therefore, a more effective way of helping farm economies is by increasing farm output prices. However, we are not sure whether an increase in farm output prices is desirable in terms of efficiency. 2) It might be worthwhile to attempt to increase the size of farmland holdings per farm household so that the mechanization of farming can be achieved more easily. 3) A kun with large out-migration suffers a deterioration in income and welfare. Therefore, the government should provide a form of subsidization similar to the adjustment assistance provided for international trade. This assistance should not be related to the level of farm output. Otherwise, there is a possibility that we might encourage farm production which would not be profitable in the absence of subsidies. 4) Government intervention in agricultural research and its dissemination, and large-scale social overhead projects in rural areas, carried out by the Korean government, might be desirable from both efficiency and equity points of view. Government interventions in research are justified because of the problems associated with the appropriation of knowledge, and government actions on large-scale projects are justified because they required collective action.

  • PDF

Geological Structures of the Hadong Northern Anorthosite Complex and its surrounding Area in the Jirisan Province, Yeongnam Massif, Korea (영남육괴 지리산지구에서 하동 북부 회장암복합체와 그 주변지역의 지질구조)

  • Lee, Deok-Seon;Kang, Ji-Hoon
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.287-307
    • /
    • 2012
  • The study area, which is located in the southeastern part of the Jirisan province of the Yeongnam massif, Korea, consists mainly of the Precambrian Hadong northern anorthosite complex (HNAC) and the Jirisan metamorphic rock complex (JMRC) and the Mesozoic granitoids which intrude them. Its tectonic frame is built into NS trend, unlike the general NE-trending tectonic frame of Korean Peninsula. This paper researched the structural characteristics at each deformation phase to clarify the geological structures associated with the NS-trending tectonic frame which was built in the HNAC and JMRC. The result indicates that the geological structures of this area were formed at least through three phases of deformation. (1) The $D_1$ deformation formed the $F_1$ sheath or "A"-type folds in the HNAC and JMRC, and the $S_{0-1}$ composite foliation and the $S_1$ foliation and the $D_1$ ductile shear zone which are (sub)parallel to the axial plane of $F_1$ fold, and the $L_1$ stretching lineation which is parallel to the $F_1$ fold axis owing to the large-scale top-to-the SE shearing on the $S_0$ foliation. (2) The $D_2$ deformation (re)folded the $D_1$ structural elements under the EW-trending tectonic compression environment, and formed the NS-trending $F_2$ open, tight, isoclinal, intrafolial folds with the $S_{0-1-2}$ composite foliation and the $S_2$ foliation and the $D_2$ ductile shear zone with S-C-C' structure and the $L_2$ stretching lineation which is (sub)parallel to the axial plane of $F_2$ fold. The extensive $D_2$ ductile shear zone (Hadong shear zone) of NS trend was persistently developed along the eastern boundary of HNAC and JMRC which would be to the limb of $F_2$ fold on a geological map scale. The Hadong shear zone is no less than 1.4 km width, and was formed in the mylonitization process which produced the mylonitic structure and the stretching lineation with the reduction of grain size during the $F_2$ passive folding. (3) The $D_3$ deformation formed the EW-trending $F_3$ kink or open fold under the NS-trending tectonic compression environment and partially rearranged the NS-trending pre-$D_3$ structural elements into (E)NE or (W)NW direction. The regional trend of $D_1$ tectonic frame before the $D_2$ deformation would be NE-SW unlike the present, and the NS-trending tectonic frame in the HNAC and JMRC like the present was formed by the rearrangement of the $D_1$ tectonic frame owing to the $F_2$ active and passive folding. Based on the main intrusion age of (N)NE-trending basic dyke in the study area, these three deformation events are interpreted to have occurred before the Late Paleozoic.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.