In this research a medical palpation guidance system for minimally invasive surgery (MIS) is proposed. Palpation is a useful tool for identifying a size and location of a lump during a surgery. However, conventional manual palpation is only available in open surgery, so there has been several researches about palpation assistant or guidance system for MIS. The previously developed systems are based on a pressure based or stiffness based approach. These previous approaches have some limitations in increasing complexity of the systems and lack of geometric information about the lump which is more important information for the lump removal than the stiffness information. We propose a palpation guidance system using a novel approach using contact pressure distribution. Since our approach gives the geometry information of the lump as well as the existence information, the operator can easily notice the currently identified lump region and the optimal position for the next palpation. The experiment results show that our approach can offer the geometry information of the lump correctly.
This study aims to analyze the sizing information of women's ready-to-wear pants as indicated on online retail websites and to suggest better sizing communication that can assist customers in making successful apparel size selections. We gathered size specifications and size reference information for basic straight pants from 34 online apparel retail websites. Although the Korean standard recommends labeling the body dimension-based sizing code and specification, most websites preferred to use various types of sizing codes. Body measurements were only used by a few websites, and garment dimension descriptions were the most common method to indicate product size. Many websites provided size reference information through customer review boards and fit model images, however, there was insufficient body size information to allow customers to infer the fit of their body type. When using the size guidance tools, the major data input points were stature and weight measurements. However, the waist measurements of pants sizes guided only by stature and weight values revealed inconsistent ease allowance for corresponding body size populations, especially in the overweight group. Based on our findings, we propose a more effective method of communicating the size information of pants online. We expect that this will contribute to the efficiency of online apparel product display and build a better shopping environment that satisfies both sellers and consumers.
Lee, Nakwon;Kim, Sang-Ha;Kwon, Woocheol;Lee, Myoung Kyu;Yong, Suk Joong;Shin, Kye Chul;Jung, Ye-Ryung;Choi, Yeun Seoung;Choi, Jiwon;Choi, Ji Sun;Lee, Won Yeon
Tuberculosis and Respiratory Diseases
/
v.77
no.6
/
pp.251-257
/
2014
Background: Transbronchial lung biopsy (TBLB) is a valuable diagnostic tool for peripheral pulmonary lesions. The diagnostic yield of TBLB reportedly ranges from 41%-60%. Many studies demonstrated the various factors that influence the yield of TBLB, including size, location, and distance from the carina or pleura. However, no study has evaluated the effects of the bronchoscope diameter. We evaluated whether the bronchoscope diameter affected the diagnostic yield of TBLB. Methods: We reviewed records from 178 patients who underwent TBLB using bronchoscopes of two different diameters (5.7 mm, thick outer diameter, Olympus BF-200; 4.9 mm, thin, BF-260). The fluoroscopic guidance rates, yield of TBLB and flexible bronchoscopy (FB) were compared between the two groups. Additionally, we compared the results of the procedures with respect to diagnosis, distance from the pleura, and size of the lesion. Results: The results of fluoroscopic guidance, TBLB, and FB yield using thin diameter bronchoscope were significantly better than those obtained with a thick diameter bronchoscope (p=0.021, p=0.036, and p=0.010, respectively). Particularly, when the distance from the pleura was ${\leq}10mm$, success rates for fluoroscopic guidance and FB with thin bronchoscope were higher (p=0.013 and p=0.033, respectively), as compared to with thick bronchoscope. Conclusion: A thinner diameter bronchoscope increased the yield of bronchoscopy, and bronchial washing in conjunction with TBLB was useful in the diagnosis of peripheral pulmonary nodules.
Journal of Korean Library and Information Science Society
/
v.9
/
pp.1-31
/
1982
A library catalog is most important finding tool to a library collection. This tool should be so designed as to enable users to handle with ease and convenience. Library catalog use study is necessary in order to identify the demands made on the catalog by its actual users and to measure the adequacy with which the catalog is meeting these demands. Many major catalog use surveys were performed by means of questionnaire and interview, but these methods are so difficult and perverse that the results of catalog use studies might often be far from scientific precision. The aim of this paper is to seek the guidelines with which one might assist the catalogers in providing an effective library catalog for their patrons. In order to get the first-hand information an actual survey was undertaken on searching behavior at the catalog of Jeonbug National University Library from November 30 to December 5, 1981 and from May 17 to May 22, 1982. The results of the survey can be summarized as follows: 1. Most of the students (79.77%) use the library. 2. Most of the library patrons (74.52%) use the public catalog as the searching tool to the library collection. 3. 67.85% of the catalog users are interested in searching materials written in Korean, Japanese, and Chinese. 4. 72.86% of the catalog users are interested in searching known items at catalog. 5. In known item searching, 49.44% of the catalog users choose title entry. 6. 20.17% of the catalog users are interested subject searching at the catalog. 7. Reference card is not utilized in searching. 8. For the translated items users want double entries in both vernacular and Korean. 9. At current catalog description, author, title, call number, translator, publisher and joint author are useful entry. Edition, author's date of birth and death, illustrative, size of book and bibliographical notes are not much utilized. 10. 55.39% of the catalog user need systematic guidance on how to use the library catalog and collection.
Soil microbial communities are immensely diverse and complex with respect to species richness and community size. These communities play essential roles in agricultural soil because they are responsible for most of the nutrient cycles in the soil and influence the plant diversity and productivity. However, the majority of these microbes remain uncharacterized because of poor culturability. Next-generation sequencing techniques have revolutionized many areas of biology by providing cheaper and faster alternatives to Sanger sequencing. Among them, amplicon pyrosequencing is a powerful tool developed by 454 Life Sciences for assessing the diversity of complex microbial communities by sequencing PCR products or amplicons. This review summarizes the current opinions in amplicon sequencing of soil microbial communities, and provides practical guidance and advice on sequence quality control, aligning, clustering, OTU- and taxon-based analysis. The last section of this article includes a few representative studies conducted using amplicon pyrosequencing.
Transactions of the Korean Society of Automotive Engineers
/
v.16
no.1
/
pp.64-70
/
2008
Temperatures of engine head and liner depend on many factors such as spray and combustion process, coolant passage flow and engine related structures. To estimate the temperature distribution of engine structure, multi-dimensional computational fluid dynamics (CFD) codes have been mainly adopted. In this case, it is of great importance to obtain the realistic wall temperature distribution of entire engine structure. In the present work, a CFD-FEM coupling methodology was presented to address this demand. This approach was applied to a real large-size marine diesel engine. CFD combustion and coolant flow simulations were coupled to FEM temperature analysis. Wall heat flux and wall temperature data were interfaced between combustion simulation and solid component temperature analysis via translator by a commercial CFD package named FIRE by AVL. Heat transfer coefficient and surface temperature data were exchanged and mapped between coolant flow simulation and FEM temperature analysis. Results indicate that there exists the optimum cell thickness near combustion chamber wall to reasonably predict the wall heat flux during combustion period. The present study also shows that the effect of cell refining on predicting in-cylinder pressure during combustion is negligible. Hence, the basic guidance on obtaining the wall heat flux needed for the reasonable CFD-FEM coupling analysis has been established. It is expected that this coupling methodology is a robust tool for practical engine design and can be applied to further assessment of the temperature distribution of other engine components.
In this study, we intend to develop a granulation tissue formation model. As a pilot experiment, a contrast agent was injected into the pylorus in 3 rats, the normal pylorus lumen size was confirmed, and a stent was placed. Stent migration was confirmed in to the duodenum within 1 week. In this experiment, stent was sutured and fixed to induce granulation tissue formation after gastrostomy under a fluoroscopic guidance. Twenty rats were divided into Healthy Group / Gastrostomy Group. After anesthesia of the Gastrostomy Group, an abdominal incision was performed, and gastrostomy was performed under a fluoroscopic guidance, and a stent was placed into the pylorus. In order to prevent stent migration due to peristalsis, suture between the pylorus and the proximal end of the stent was performed. Postoperative behavior and weight changes were monitored daily. Four weeks after surgery, gastrointestinal fluoroscopy imaging was performed and rats were sacrifices. To evaluate the degree of granulation formation, the stent was sectioned transversely. Gastrostomy group was statistically significantly higher than Healthy Group in granulation area ratio (all p<.001). In conclusion, it is considered that the level of tissue overgrowth formation for preclinical evaluation of the pylorus stricture model through gastrostomy is appropriate as a research evaluation tool.
The dynamic behaviour of the rock mass under the dynamic load is different from the static application of the maximum load of the same size. An experimental approach to investigating rock behavior under dynamic loads is more difficult than that under static conditions in control of dynamic loads, measurement and analysis of the results. Numerical methods are less constrained by performing the experiments numerically, rather than experimental ones, so they can be very powerful analytical tool at the design stage. However, even if the algorithms of the analysis method are appropriate, careful analysis is required because the calculation results may vary largely depending on input data and boundary conditions. In this paper, when investigating the behavior of rock structures under dynamic load numerically, the effects of boundary conditions, dynamic load and calculation time step, and dynamic load characteristics on the calculation results were reviewed to provide guidance on setting up boundary conditions and calculation time step related to dynamic analysis.
Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.
The state-of-the-art Earth system model as a virtual Earth is required for studies of current and future climate change or climate crises. This complex numerical model can account for almost all human activities and natural phenomena affecting the atmosphere of Earth. The Unified Model (UM) from the United Kingdom Meteorological Office (UK Met Office) is among the best Earth system models as a scientific tool for studying the atmosphere. However, owing to the expansive numerical integration cost and substantial output size required to maintain the UM, individual research groups have had to rely only on supercomputers. The limitations of computer resources, especially the computer environment being blocked from outside network connections, reduce the efficiency and effectiveness of conducting research using the model, as well as improving the component codes. Therefore, this study has presented detailed guidance for installing a new version of the UM on high-performance parallel computers (Linux clusters) owned by individual researchers, which would help researchers to easily work with the UM. The numerical integration performance of the UM on Linux clusters was also evaluated for two different model resolutions, namely N96L85 (1.875° ×1.25° with 85 vertical levels up to 85 km) and N48L70 (3.75° ×2.5° with 70 vertical levels up to 80 km). The one-month integration times using 256 cores for the AMIP and CMIP simulations of N96L85 resolution were 169 and 205 min, respectively. The one-month integration time for an N48L70 AMIP run using 252 cores was 33 min. Simulated results on 2-m surface temperature and precipitation intensity were compared with ERA5 re-analysis data. The spatial distributions of the simulated results were qualitatively compared to those of ERA5 in terms of spatial distribution, despite the quantitative differences caused by different resolutions and atmosphere-ocean coupling. In conclusion, this study has confirmed that UM can be successfully installed and used in high-performance Linux clusters.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.