• Title/Summary/Keyword: size difference

Search Result 5,036, Processing Time 0.036 seconds

An Efficient Time-Domain Electromagnetic Solution Using the Time-Domain Variable Resolution Concept (가변 시간 분해능 시간 영역 전자파 해석법)

  • Kim Hyung-Hoon;Park Jong-Il;Kim Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.890-894
    • /
    • 2006
  • To make the best use of known characteristics of the alternating-direction-implicit finite-difference time-domain (ADI-FDTD) method such as unconditional stability and modeling accuracy, an efficient time domain solution with variable time-step size is proposed. Numerical experiment shows that a time-step size for a given mesh size can be increased preserving a desired numerical accuracy over frequencies of interest. The proposed method can be used to analyze electromagnetic problems with reduced computation time.

$CO_2$ Laser Beam Welding and Formability of Steel Plates with Different Thicknesses (이종두께 강판의 $CO_2$ 레이저 용접 및 성형성)

  • Suh, J.;Han, Y.H.;Kim, J.O.;Lee, Y.S.
    • Journal of Welding and Joining
    • /
    • v.14 no.1
    • /
    • pp.82-91
    • /
    • 1996
  • The maximum butt-joint gap size in $CO_2$ laser beam welding of SAPH steel plates with different thicknesses and its bending formability were studied. In the range of the gap size$\geq$0.1mm, the optimal butt welding speed was faster than that of no gap (air gap) condition. This behaviour was independent on the difference of thickness at any combination. Also, the allowable gap size in steel plates with different thicknesses was larger than with same thicknesses. In the range of $T/T_0$(bead shape) $\geq$ 0.8, good bending formability was obtained at any combination of thickness. The formability was improved by reducing the hardness in weld bead using pre-heating process. Finally, FEM result of the laser beam welded underframe with different thicknesses was compared to that of the conventional spot welded underframe.

  • PDF

The Influence of External Stress on the Degradation Phenomena of PZT Ceramics (외부응력에 의한 PZT압전세라믹스의 열화현상)

  • Im, Jin-Ho;Lee, Jun-Hyeong;Kim, Jin-Ho;Jo, Sang-Hui
    • Korean Journal of Materials Research
    • /
    • v.4 no.4
    • /
    • pp.439-444
    • /
    • 1994
  • The influence of the direction of applied compressive stress on degradation mechanism ofpoled PZT sample was studied. When compressive stress perpendicular to poling direction was appliedon poled PZT sample, the degradation phenomena was explained by the diffusion of space chargepolarization. On the contrary, compressive stress parallel to poling direction was applied, it wasexplained by the rearrangement of 90" domains. As the grain size increased, the degradation phenomenawas promoted. It is attributed to different internal stress due to difference of grain size. of grain size.

  • PDF

Size Measurements of Droplets Entrained in a Stagnant Bubbling Liquid Column

  • Jeong, Hae-Yong;No, Hee-Cheon;Song, Chul-Hwa;Chung, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.254-259
    • /
    • 1996
  • Phase Doppler particle analyze. (PDPA) is a instrument which can be used to obtain simultaneous size and velocity measurements in a multiphase flow. In this study, the size of the water droplets entrained from a bubbling surface of a stagnant liquid column is measured by PDPA with a specially designed transmitter of long focal length and large beam diameter. The test section tube is made of acryle with 18 mm I.D. and 900 mm length. The experimental data are obtained for the air superficial velocity between 0.7 m/s to 3.4 m/s at atmospheric pressure. The experimental results show that there exists large difference in the entrainment mechanism between the churn-turbulent flow and annular flow. Through the present study, the phase Doppler analyzer system is shown to be successfully applied to measure particle sizes larger than $2,000\mu\textrm{m}$ if a transmitter of long focal length is utilized.

  • PDF

The Effects of the Microstructural Change of Dual Phase Steel on Fatigue Fracture Propagation (복합조직강의 미시조직변화가 피로파괴전파에 미치는 영향)

  • Oh, Sae-Wook;Kim, Ung-Jip
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.58-66
    • /
    • 1991
  • Not only difference of fatigue crack growth and propagation behavior resulted from the grain size, the hardness ratio and volume fraction in M.E.F. dual phase steel composed of martensite in hard phase and ferrite in soft phase, but also the effects of the plastic constraint were investigated by fracture mechanics and microstructural method. The main results obtained are as follows: 1) The fatigue endurance of M.E.F. steel increases with decreasing the grain size, increasing the ratio of hardness and volume fraction. 2) The initiation of slip and crack occures faster as the stress level goes higher. These phenomena result from the plastic constraint effect of the second phase. 3) The crack propagation rate in the constant stress level is faster as the grain size gets larger, the ratio of hardness lower and volume fraction smaller.

  • PDF

Effect of Polymer Content on Synthesis Process and Microstructure of Alumina-Zirconia Composite (알루미나-지르코니아 복합체의 제조공정 및 미세구조에 미치는 폴리머 첨가의 영향)

  • 이상진;권명도;이충효;조경식
    • Journal of Powder Materials
    • /
    • v.10 no.5
    • /
    • pp.310-317
    • /
    • 2003
  • Two-component ceramic (alumina-zirconia) composites were fabricated by a soft-solution process in which polyethylene glycol (PEG) was used as a polymeric carrier. Metal salts and PEG were dissolved in ethyl alcohol without any precipitation in 1:1 volume ratio of alumina and zirconia. In the non-aqueous system, the flammable solvent made explosive, exothermic reaction during drying process. The reaction resulted in formation of volume expanded, porous precursor powders by a vigorous decomposition of organic components in the precursor sol. The PEG content affected the grain size of sintered composites as well as the morphology of precursor powders. The difference of microstructure in sintered composite was attribute to the solubility and homogeneity of metal cations in precursor sol. At the optimum amount of the PEG polymer, the metal ions were dispersed effectively in solution and a homogeneous polymeric network was formed. It made less agglomerated particles in the precursor sol and affected on uniform grain size in sintered composite.

Effect Of Bedding on the Microstructure of Si3N4 with Ultrafine SiC (초미립 SiC가 첨가된 질화규소에서 미세구조에 미치는 Bedding의 영향)

  • 이홍한;김득중
    • Journal of Powder Materials
    • /
    • v.10 no.1
    • /
    • pp.57-62
    • /
    • 2003
  • The effect of bedding on the microstructure of $Si_3N_4$ added with ultra-fine SiC was investigated. The bedding and the addition of ultra-fine SiC effectively inhibited grain growth of $Si_3N_4$ matrix grain. The microstructures of the specimens sintered with bedding powder consisted of fine-grains as compared with the specimens sintered without bedding powder. In addition, the grain size and the difference of grain size between the specimens sintered with bedding and without bedding was reduced with increasing SiC content. Some ultra-fine SiC particles were trapped in the $Si_3N_4$ grains growed. The number of SiC particles trapped in the $Si_3N_4$ grains increased with increasing the grain growth. When ultra-fine SiC particles were added in the $Si_3N_4$ ceramics, the strength was improved but the toughness was decreased, which was considered to be resulted from the decrease of the grain size.

구두제작을 위한 청년남성의 발치수 분석

  • 천종숙;최선희
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.297-303
    • /
    • 1997
  • This study was initiated to investigate suitability of men's dress shoe sizes made for young men. Experiments were performed on 172 men for 19 to 29 years of age. Nine dimensions were measured from the subject's right foot and 11 dimensions were measrued from the outline of the foot. The data were analyzed for six different groups. The subjects were grouped by their dress shoe size or the ratio of the foot width to foot length. The result of the experiments lead to the following conclusions: 1. Foot length, metatarsal width and heel width were significantly different among the small, medium and large dress shoe size groups. 2. No significant differences in front foot angle and the inside metatarsal width were found among the above three groups. 3. The difference between wearing shoe size and the foot length was larger for the subjects with wide foot shape.

  • PDF

Specific Absorption Rate Values of Handsets in Cheek Position at 835 MHz as a Function of Scaled Specific Anthropomorphic Mannequin Models

  • Lee, Ae-Kyoung;Choi, Hyung-Do;Choi, Jae-Ick;Pack, Jeong-Ki
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.227-230
    • /
    • 2005
  • A specific anthropomorphic mannequin (SAM) model was used to investigate the relation between local specific absorption rate (SAR) and head size. The model was scaled to 80 to 100% sized models at intervals of 5%. We assumed that the shell of the SAM model has the same properties as the head-equivalent tissue. Five handsets with a monopole antenna operating at 835 MHz were placed in the approximate cheek position against the scaled SAM models. The handsets had different antenna lengths, antenna positions, body sizes, and external materials. SAR distributions in the scaled SAM models were computed using the finite-difference time-domain method. We found that a larger head causes a distinct increase in the spatial peak 1-voxel SAR, while head size did not significantly change the peak 1-g averaged-SAR and 10-g averaged-SAR values for the same power level delivered to the antenna.

  • PDF

SYSTEMATIC INCREASE OF DUST SIZE TOWARD THE CENTER OF B361

  • Hong, S.S.;Koo, B.C.;Yun, H.S.
    • Journal of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.107-116
    • /
    • 1991
  • With a modern microdensitometer and POSS glass copies, we have performed an automated star counting in two colors, blue and red, over the region containing Bok globule B361. Distribution of the measured extinction values over the projected angular distance from the cloud center was approximated by a power-law, and the resulting power-law indices for the blue and red are shown to be distinctly different from each other. The difference in the power-law index indicates that the mean dust size increases towards the cloud center. Possible physical causes for such size variation are briefly discussed.

  • PDF