• 제목/요약/키워드: size and number concentration of particle

검색결과 184건 처리시간 0.022초

OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포 (Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001)

  • 정창훈;전영신;최병철
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

제주 고산 지역의 에어러솔 수농도 변동과 기상요소와의 상관성 연구 : 2001-2003 (Relationship between Meteorological Elements and Aerosols Number Concentration at Gosan, Jeju for $2001{\sim}2003$)

  • 이명주;오성남;김은연;장기호
    • 한국방재학회 논문집
    • /
    • 제6권3호
    • /
    • pp.47-56
    • /
    • 2006
  • 기후변화와 관련한 한반도 배경대기의 에어러솔에 대한 특성 연구는 관측된 입자 수농도와 대기 복사 관측 자료를 바탕으로 에어러솔의 물리적, 화학적 및 광학적 특성에 대하여 분석하였다. 에어러솔의 물리적 특성 연구는 2001년부터 2003년까지 제주도 고산관측소에 설치된 광학입자계수기(Optical Particle Counter, OPC)로 $0.3{\sim}25{\mu}m$직경의 에어러솔을 8개 구간으로 나누어 관측하여 분석하였다. 그 결과 황사의 발생률이 높은 봄철에 조대 입자($2.2{\mu}m$이상)의 수농도가 다른 계절보다 높게 나타났다. 기상요소 (상대습도, 풍속, 풍향, 시정 등)와 입자 수농도의 상관관계 분석에 의하면 $0.3{\sim}0.5{\mu}m$ 크기 구간에서는 상관성이 없는 것으로 나타났으며 $0.5{\sim}2.23{\mu}m$ 구간에서는 에어러솔 수농도와 상대습도가 서로 양의 상관관계를 가지는 것으로 나타났다. 풍속과의 상관성에서 작은 입자들은 풍속이 강해질수록 감소하는 패턴으로 분석되었으며 겨울철에는 조대입자 수농도가 높은 풍속에 증가하는 것으로 나타났다. 그리고 시정거리는 $0.5{\sim}1{\mu}m$ 크기 정도의 에어러솔 수 농도와 밀접한 관련이 있는 것으로 나타났으며 에어러솔 수 농도가 증가할수록 시정거리는 감소하는 경향을 보였다.

The effect of dynamic operating conditions on nano-particle emissions from a light-duty diesel engine applicable to prime and auxiliary machines on marine vessels

  • Lee, Hyungmin;Jeong, Yeonhwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.403-411
    • /
    • 2012
  • This study presents the nano-sized particle emission characteristics from a small turbocharged common rail diesel engine applicable to prime and auxiliary machines on marine vessels. The experiments were conducted under dynamic engine operating conditions, such as steady-state, cold start, and transient conditions. The particle number and size distributions were analyzed with a high resolution PM analyzer. The diesel oxidation catalyst (DOC) had an insignificant effect on the reduction in particle number, but particle number emissions were drastically reduced by 3 to 4 orders of magnitude downstream of the diesel particulate filter (DPF) at various steady conditions. Under high speed and load conditions, the particle filtering efficiency was decreased by the partial combustion of trapped particles inside the DPF because of the high exhaust temperature caused by the increased particle number concentration. Retarded fuel injection timing and higher EGR rates led to increased particle number emissions. As the temperature inside the DPF increased from $25^{\circ}C$ to $300^{\circ}C$, the peak particle number level was reduced by 70% compared to cold start conditions. High levels of nucleation mode particle generation were found in the deceleration phases during the transient tests.

입자가 부유된 고온의 제트유동에서 응집과 부력을 고려한 이차원 입자크기 분포해석 (A two dimensional analysis of the evolution of the particle size distribution in particle laden high temperature jet flows including the effects of coagulation and buoyancy)

  • 이방원;최만수;황정호
    • 대한기계학회논문집B
    • /
    • 제21권3호
    • /
    • pp.380-391
    • /
    • 1997
  • A numerical study has been done on the evolution of particle size distribution in particle laden high temperature jet flows undergoing convection, diffusion, thermophoresis and coagulation. The dynamic behavior of these particles have been modelled by approximating the particle size distribution by a lognormal function throughout the process and the moments of the particle size distribution have been used to solve the general dynamic equation. The size distributions of spherical particles in the radial and axial direction have been obtained including the effect of buoyancy. Of particular interests are the variations of geometric mean diameter, number concentration and polydispersity. Results show that buoyancy significantly alters the size distribution in both axial and radial direction. One dimensional analysis for non-spherical particles has also been done and the results have been compared with the existing experimental data.

디젤 입자상물질의 크기분포 특성에 관한 실험적 연구 (Experimental Study on the Size Distribution of Diesel Particulate Matter (DPM))

  • 연익준;권순박;이규원
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.11-17
    • /
    • 2002
  • Diesel particulate matter (DPM) is known to be one of the major harmful emissions produced by diesel engines. The majority of diesel particles are in the range of smaller than $I{\mu}\textrm{m}$. Because of their tiny volume, ultrafine diesel particles contribute very little to the total mass concentration which is currently regulated for automobile emissions. Diesel particles are known to have deleterious effects upon human health because they penetrate human respiratory tract and have negative effects on the health. The measurement of the number distribution of nanometer size particles (nanoparticles) in the diesel exhaust emission is important in order to evaluate their environmental and health impact, and to develop new types of diesel particulate filters. In this study, we directly sampled particulate matters emitted from a diesel truck mounted on the chassis dynamometer by a flow separator and dilution system, and measured the nanoparticles using two types of differential mobility analyzers combined with a Faraday cup electrometer (FCE) and a condensation particle counter (CPC). The particle size distributions were analyzed by changing engine operation condition, i.e. ratio of engine loading. The total number concentration of particles were increased with the engine loading ratio and the nanoparticles (less than 50nm) were affected by hydrocarbon (HC) concentration in the diesel exhaust.

PTFE 크기 변화에 따른 Carbon Cloth 발수 코팅과 가스 투과도 변화 (Water Repellent Coating of Carbon Cloth with Different Size PTFE and Gas Permeabilities)

  • 전현;조태환;최원경
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.313-320
    • /
    • 2010
  • Carbon cloth was impregnated into PTFE emulsion. PTFE is a fluoropolymer used as a coating material in various fields due to its hydrophobicity and excellent mechanical properties. In this study, PTFE emulsion was prepared different particle size of 5~500 nm and $3{\sim}5{\mu}m$. FE-SEM and FT-IR spectroscopy were used microscopic observation and investigation of chemical structure change after PTFE coating. Mass variations, gas permeability and water contact angles were analyzed to determine a GDL performance of PTFE coated carbon cloth. PTFE coated carbon cloth show different mass increase according as PTFE concentration and the number of coating times. Water contact angle of PTFE coated carbon cloth was not effected by size of PTFE particle and the number of coating time; meanwhile, gas permeability was rapidly changed at carbon cloth coated by emulsion with size of $3{\sim}5{\mu}m$ PTFE particle.

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

저압상태에서 공기역학적 렌즈를 이용한 In-Situ Particle Monitor의 성능특성 분석 (Investigation of the Performance Characteristics of an In-Situ Particle Monitor at Low Pressures Using Aerodynamic Lenses)

  • 배귀남
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1359-1367
    • /
    • 2000
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at low pressures has been studied. We generated the uniform sized methylene blue particle beams using three identical aerodynamic lenses in the center of the vacuum line, and measured the detection efficiency of the ISPM. The effects of particle size, particle concentration, mass flow rate, system pressure, and arrangement of aerodynamic lenses on the detection efficiency of the ISPM were examined. Results show that the detection efficiency of the ISPM greatly depends on the mass flow rate, and the particle Stokes number. We also found that the optimum Stokes number ranges from 0.4 to 1.9 for the experimental conditions.

라그란지안 입자확산모델개발(농도 계산방법의 검토) (A Development of Lagrangian Particle Dispersion Model (Focusing on Calculation Methods of the Concentration Profile))

  • 구윤서
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.757-765
    • /
    • 1999
  • Lagrangian particle dispersion model(LPDM) is an effective tool to calculate the dispersion from a point source since it dose not induce numerical diffusion errors in solving the pollutant dispersion equation. Fictitious particles are released to the atmosphere from the emission source and they are then transported by the mean velocity and diffused by the turbulent eddy motion in the LPDM. The concentration distribution from the dispersed particles in the calculation domain are finally estimated by applying a particle count method or a Gaussian kernel method. The two methods for calculating concentration profiles were compared each other and tested against the analytic solution and the tracer experiment to find the strength and weakness of each method and to choose computationally time saving method for the LPDM. The calculated concentrations from the particle count method was heavily dependent on the number of the particles released at the emission source. It requires lots fo particle emission to reach the converged concentration field. And resulting concentrations were also dependent on the size of numerical grid. The concentration field by the Gaussian kernel method, however, converged with a low particle emission rate at the source and was in good agreement with the analytic solution and the tracer experiment. The results showed that Gaussian kernel method was more effective method to calculate the concentrations in the LPDM.

  • PDF

광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성 (Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon)

  • 최병철;;임재철;정상부;김윤석;;;;김상백;홍기만;이영곤;유희정
    • 대기
    • /
    • 제15권3호
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.