• Title/Summary/Keyword: site contaminants

Search Result 138, Processing Time 0.025 seconds

Deterioration Assessment for Conservation Sciences of the Five Storied Stone Pagoda in the Jeongrimsaji Temple Site, Buyeo, Korea (부여 정림사지 오층석탑의 보존과학적 풍화훼손도 평가)

  • Kim, Yeong-Taek;Lee, Chan-Hee;Lee, Myeong-Seong
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.675-687
    • /
    • 2005
  • The rocks of the five storied stone pagoda in the Jeongrimsaji temple site are 149 materials in total with porphyritic biotite granodiorite. They include pegmatite veinlet, basic xenolith and evenly developed plagioclase porphyry. This stone pagoda has comparably small fracture and cracks which are farmed in the times of rock properties, but surface exfoliation and granular decomposition are in process actively since the rocks are generally weakened from the influence of air contaminants and acid rain. Structural instability of constituting rocks in the 4th roof materials are observed to occur from distortion and tilt. Such instability is judged to threat stability of the upper part of the stone pagoda. Also, chemical weathering is operating even more as the contaminants, ferro-manganese hydroxides eluted from water-rock interaction on the rock surface. Most of the rock surface is covered with yellowish brown, dark black and light gray contaminants, and especially occur in the lower part of the roof rocks on each floor. The roof underpinning rocks are severe in surface pigmentation from manganese hydroxides and light gray contaminants. The surface of rocks lives bacteria. algae, lichen, or moss and diverse productions in colors of light gray, dark Bray and dark green. Grayish white crustose lichen grows thick on the surface with darkly discolored by fungi and algae in the first stage on basement rocks, and weeds grows wild on the upper part of each roof rocks. This stone pagoda must closely observe the movements of the upper part rock materials through minute safety diagnosis and long term monitoring for structural stability. Especially since the surface discoloration of rocks and pigmentation of secondary contaminants are severe, establishment of general restoration and scientific conservation treatment are necessary through more detailed study for this stone pagoda.

Contaminant Mechanism and Management of Tracksite of Pterosaurs, Birds, and Dinosaurs in Chungmugong-dong, Jinju, Korea (천연기념물 진주 충무공동 익룡·새·공룡발자국 화석산지의 오염물 형성 메커니즘과 관리방안)

  • Myoungju Choie;Sangho Won;Tea Jong Lee;Seong-Joo Lee;Dal-Yong Kong;Myeong Seong Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.715-728
    • /
    • 2023
  • Tracksite of pterosaurs, birds, and dinosaurs in Chungmugong-dong in Jinju was designated as a natural monument in 2011 and is known as the world's largest in terms of the number and density of pterosaur footprints. This site has been managed by installing protection buildings to conserve in 2018. About 17% of the footprints of pterosaur, theropod, and ornithopod in this site under management in the 2nd protection building are of great academic value, but observation of footprints has difficulties due to continuous physical and chemical damage. In particular, the accumulation of milk-white contaminants is formed by the gypsum and air pollutant complex. Gypsum remains evaporated with a plate or columnar shape in the process of water circulation around the 2nd protection building, and the dust is from through the inflow of the gallery windows. The aqueous solution of gypsum, consisting of calcium from the lower bed and sulfur from grass growth, is catchmented into the groundwater from the area behind the protection building. Pollen and a few minerals other constituents of contaminants, go through the gallery window, which makes it difficult to expel dust. To conserve the fossil-bearing beds from two contaminants of different origins, controlling the water and atmospheric circulation of the 2nd protection building and removing the contaminants continuously is necessary. When cleaning contaminants, the steam cleaning method is sufficiently effective for powder-shaped milk-white contaminants. The fossil-bearing bed consists of dark gray shale with high laser absorption power; the laser cleaning method accompanies physical loss to fossils and sedimentary structures; therefore, avoiding it as much as possible is desirable.

Suggestion for Legal Definitions of Keywords on Soil Contamination Policies in Korea (토양환경보전법의 토양오염 관련 주요 용어의 정의 및 재정립에 관한 고찰)

  • Park, Yong-Ha;Yang, Jae-E.
    • Journal of Environmental Policy
    • /
    • v.4 no.1
    • /
    • pp.39-67
    • /
    • 2005
  • In order to properly define the terms such as soil, soil contamination, soil contamination site and remediation, which are the key terms under the Soil Environment Conservation Act(SECA) in Korea, we analyzed the legal definitions of the similar key words in legislations of the developed western countries. The selected countries were the United States of America, the United Kingdom, the Netherlands, Germany, and Denmark. The legal definitions of these keywords were very much diversified due to different levels of soil contamination, as well as different industrial, social, and legal backgrounds in each country. However, fair suggestions for definitions of the key terms in SECA were derived from the comparative analyses of these countries. First and foremost, SECA should provide a definition of 'soil' which includes a concept of the natural soil layer produced from soil mineralization processes. Groundwater and sublayer of the groundwater would. be excluded in the boundary of the soil with regards to the Groundwater Act of Korea. Definition of 'soil contamination' of SECA should include a concept of risk assessment(soil contaminants, pathway, and receptors), purpose of land use, and the acquired limitation levels of soil contaminants. Soil contamination activity either industrial or anthropogenic in SECA article2-1, could be substituted for a concept of soil risk assessment. Definition of 'soil contamination site' could derive from amalgamating the concepts of i) soil contamination in conjunction with contaminants, ii) risk assessment, iii) a concept of land use, and iv) knowing limitation of contamination site designation. Definition of 'remediation of contaminated site' should include the objective, intention, action, methodology and limit of the remediation. These suggested definitions would increase the efficacy of soil environment conservation policies, which includes the survey of the potentially contaminated area, remediation, and removal of the site.

  • PDF

Runoff Characteristics of the Livestock Manure as Fertilizer at Farmland (가축분뇨 비료의 농지 유출 특성)

  • Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.775-780
    • /
    • 2010
  • Over 90% of the livestock excretions were treated and utilized by land application in Korea. Excessive application of the livestock manure as fertilizer has been issued as a main pollutant source in groundwater and watersheds. This study was seasonally conducted to identify the discharging characteristics with a certain artificial rainfall intensity (13 mm/hr) in terms of surface runoff, groundwater, and soil residue mass depending on the livestock manure types. A experimental field was constructed with three different sites that pig liquid fertilizer (LF), cattle manure (CM), and standard (S). The pig liquid fertilizer of 1,200 L and cattle manure of 900 kg were sprayed on each site ($50m^2$). The standard area was firmly prevented from any other contaminants. In the LF site, farmland discharging rate (FDR) was computed as 0.006 in CODcr, 0.015 in TN, and 0.029 in TP, resulted from the mass balance among total injection mass, surface runoff and groundwater. In the CM site, 29% of the nitrogen and phosphorus in each were discharged to the surface, and 64% and 58% of them were remained in the farmland. Surface runoff rate of the CM was higher than that of the LF, resulted from the solid form of the CM.

Characteristics of Distribution and Potential Route of Contaminants at Waste Disposal Site (폐기물매립지 주변의 오염물질 분포 및 이동 특성)

  • 박성원;황세호;이평구;박인화;신성천;이상규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.144-148
    • /
    • 2001
  • A geophysical and geochemical study was performed to verify the depth of landfill as well as the horizontal/vertical distribution of leachate at the landfill site located in Gongju. The electrical resistivity, with dipole-dipole array and dipole spacing of 5m, was applied along the nine survey lines and electromagnetic induction survey was conducted along the perimeter traverse surrounding the landfill. Cations, anions and stable isotope ($\delta$D and $\delta$$^{18}$ O) analyses were performed on about 63 water and leachate samples collected in dry and rainy seasons at 31 sites. The result of electromagnetic induction survey make it possible to derive the potential route of leachate in the past or present. The imaging of processed resistivity field data show that the possible route of leachate doesn't exist except the survey line 7. The weak zone traversing the landfill, however, is revealed by the electrical resistivity imaging, which may be the potential route of leachate toward the deep ground. The geochemical data agree well with geophysical data for deducing possible route of leachate of the site.

  • PDF

The Assessment of Stabilization of Open-dumping Landfill Leachate - A Case Study of Noeun Landfill - (비위생매립지 침출수의 안정화 평가 - 노은매립지 사례연구 -)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.3
    • /
    • pp.115-124
    • /
    • 2004
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill (Noeun Landfill) which is located at the upper drainage basin of Namhan River which flows into Lake Paldang utilized for Seoul Metropolitan water supplies, the surrounding characteristics of the landfill site was surveyed. After then, leachate, groundwater and soil samples from this landfill were chemically analyzed, and the analysis results were evaluated by "The Criteria of Landfill Waste Stabilization(CLWS)", "Discharge Criteria of Landfill Leachate", "The Criteria of Domestic Use in Groundwater Quality", and "Soil Contamination Criteria" promulgated by Korean Ministry of Environment. The closed open-dumping landfill was equipped with the final soil cover, 3 groundwater monitoring wells and poor landfill gas extraction devices for the post-closure management of the landfill. BOD/CODcr ratios in leachate were less than or slightly higher than 1/10. This results seemed to imply that the leachate stabilization level of this landfill based on the CLWS was almost completed. Qualities of groundwater sampled from monitoring wells located at outside of landfill were adequate for "The Criteria of Domestic Use in Groundwater Quality". Finally, concentrations of soil contaminants that were likely to be influenced by this landfill site were adequate to "Soil Contamination Criteria".

Electrical Resistivity Investigation at a Wastes Disposal Site (전기비저항 탐사를 이용한 매립지 안정화 조사)

  • Ha, Hee-Sang;Jung, Yun-Mun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.70-86
    • /
    • 2000
  • The primary objective of this study is to develope an investigating method to identify spatial variability of plumes and contaminants at contaminated sites. The electrical resistivity method was used to characterize contaminated sites. This technique is expected to use actively at contaminated sites in order to remedy the contaminated sites in the future. It was studied by appling electrical resistivity method into contaminated wastes disposal sites and verified that it was suitable method for the contaminated site characterization.

  • PDF

Evaluation of Leachate Containment by Soil-cement Walls for a Closed Landfill (사용종료매립지 정비를 위한 흙-시멘트 연직차수벽의 차수성능 평가)

  • Lee, Dong-Geon;Ahn, Jo-Hwan;Kwon, Ki-Wook;Koo, Ja-Kong;Bae, Woo-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.1
    • /
    • pp.62-70
    • /
    • 2011
  • This study was conducted to evaluate the performance of soil-cement walls (SCWs) to control leachate from a leaking landfill site. Tracer tests revealed that the SCW was effective to control groundwater seepage. Approximately two-months of curing period appeared to be sufficient to ensure thorough containment of landfill leachate, although a three-week period was not enough. The water quality of the monitoring wells after construction of the SCWs met the groundwater quality standard of the korean Waste Management Act, except for bacteria and coliform groups. Also an analysis of a spring water around the landfill showed that the concentrations of ammonia, inorganic nitrogen and soluble manganese which had been common contaminants in the spring water decreased dramatically after constructing the walls. Therefore, the results suggested that a SCW can be an attractive method to control leachate from a leaking landfill site.

Novel approach to predicting the release probability when applying the MARSSIM statistical test to a survey unit with a specific residual radioactivity distribution based on Monte Carlo simulation

  • Chun, Ga Hyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1606-1615
    • /
    • 2022
  • For investigating whether the MARSSIM nonparametric test has sufficient statistical power when a site has a specific contamination distribution before conducting a final status survey (FSS), a novel approach was proposed to predict the release probability of the site. Five distributions were assumed: lognormal distribution, normal distribution, maximum extreme value distribution, minimum extreme value distribution, and uniform distribution. Hypothetical radioactivity populations were generated for each distribution, and Sign tests were performed to predict the release probabilities after extracting samples using Monte Carlo simulations. The designed Type I error (0.01, 0.05, and 0.1) was always satisfied for all distributions, while the designed Type II error (0.01, 0.05, and 0.1) was not always met for the uniform, maximum extreme value, and lognormal distributions. Through detailed analyses for lognormal and normal distributions which are often found for contaminants in actual environmental or soil samples, it was found that a greater statistical power was obtained from survey units with normal distribution than with lognormal distribution. This study is expected to contribute to achieving the designed decision error when the contamination distribution of a survey unit is identified, by predicting whether the survey unit passes the statistical test before undertaking the FSS according to MARSSIM.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.