• 제목/요약/키워드: site coefficient

검색결과 726건 처리시간 0.032초

Assessment of soil density and distribution coefficient of Cs-137 for deriving DCGLs in korea research reactor unit 1 and 2

  • Geun-Ho Kim;Ilgook Kim;Kwang Pyo Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2452-2457
    • /
    • 2024
  • To obtain site-specific values of the Derived Concentration Guideline Levels (DCGLs) for decommissioning of KRR-1&2, the soil density and distribution coefficient values for Cs-137, a major contaminant radionuclide, were determined. The soil density was evaluated according to the test method established by the Korean Agency for Technology and Standards of the Ministry of Trade, Industry, and Energy (KATS). The distribution coefficient was evaluated using a batch test. The validity of using the evaluated soil density and distribution coefficient as site-specific values was assessed through radiation dose assessment reflecting these values. Average soil density value obtained was 1.738 g/cm3, which was within the typical range of normal soil density, 1.0-1.8 g/cm3. The average distribution coefficient value was 7,754 mL/g. Applying the maximum, average, and minimum values of the evaluated soil density and distribution coefficient showed similar radiation dose results, thus suggesting that it is reasonable to use the average values of each parameter as site-specific values. Findings of this study can help determine DCGLs that reflect the characteristics of the research reactor site.

실내환경과 건설현장 온도변수를 고려한 고력볼트 체결력 예측 (Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments)

  • 나환선;이현주
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.32-40
    • /
    • 2015
  • The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from $-11^{\circ}C$ to $34^{\circ}C$. The indoor temperature condition was ranged from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to $556 N{\cdot}m$. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is $0.13%/^{\circ}C$ while it reaches $2.73%/^{\circ}C$ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as $0.2%/^{\circ}C$. and the modified variable of tension can be determined as $0.18%/^{\circ}C$.

확률론적 지진계수 개발 (Development of Probabilistic Site Coefficient)

  • 곽동엽;정창균;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.707-714
    • /
    • 2009
  • The design response spectrum generally used in Korea is decided by the site coefficients determined by deterministic methodology, while it is based on probabilistic seismic hazard analysis. The design response spectrum has to be made using probabilistic method which includes uncertainties of ground motions and ground properties for coincide with probabilistic methodology of seismic hazard analysis. In this study probabilistic site coefficients were developed, which were defined by the results of site response analysis using a set of ground motion that was compatible with present seismic hazard map. The design response spectrum defined by probabilistic seismic coefficients resulted in lower spectrum in long period area and larger spectrum in short period area. Also, the maximum spectral accelerations in site class D and site class E were lower than one in site class C while in the previous design response spectrum the maximum spectral acceleration increased from site class A to E.

  • PDF

국내외 판내부 지진기록을 사용한 국내 지반의 지반운동 증폭특성 규명 및 토사지반의 표준설계응답스펙트럼의 제안 (Amplification Characteristics of Domestic and Overseas Intraplate Earthquake Ground Motions in Korean Soil and Standard Horizontal Design Spectrum for Soil Sites)

  • 이진호;김정한;김재관
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.391-399
    • /
    • 2018
  • The site coefficients in the common requirements for seismic design codes, which were promulgated in 2017, were reevaluated and the standard design spectrum for soil sites were newly proposed in order to ensure the consistency of the standard design spectra for rock and soil sites specified in the common requirements. Using the 55 ground motions from domestic and overseas intraplate earthquakes, which were used to derive the standard design spectrum for rock sites, as rock outcropping motions, site response analyses of Korean soil were performed and its ground-motion-amplification was characterized. Then, the site coefficients for soil sites were reevaluated. Compared with the existing site coefficients, the newly proposed short-period site coefficient $F_a$ increased and the long-period site coefficient $F_v$ decreased overall. A new standard design spectrum for soil sites was proposed using the reevaluated site coefficients. When compared with the existing design spectrum, it could be seen that the proposed site coefficients and the standard design spectrum for soil sites were reasonably derived. They reflected the short-period characteristics of earthquake and soil in Korea.

수치영상을 이용한 토량환산계수 산정 (The Estimation of Soil Conversion Factor using Digital Imagery)

  • 이종출;차성렬;장호식;김진수
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.169-174
    • /
    • 2003
  • Design of a rational earth volume conversion coefficient is required as the earth volume conversion coefficient may give great influence on construction work volume and construction costs in the civil engineering works where large-scaled earth volume is excavated. However, there are a great deal of difficulties in the calculation of the exact spoil surface earth and Insufficient earth volume by adopting the figures presented on the generally used design specifications which are not the results obtained from the selection tests in calculating the earth volume conversion coefficient. In this connection, it would be desirable to calculate the earth volume conversion coefficient by carrying out large-scaled site test adequate for the relevant environment. In consequence, this study aims at calculating the exact earth volume conversion coefficient of cutting and banking areas of weathering rocks in large-scaled construction sites where land is being developed into home lots. For this, we have excavated the respective 20 sites of the cutting and banking areas in the said site and then calculated the volume after the excavation. As a result, the relative exactness degree of the crossing was calculated at 0.5% in average. The relative exactness degree of 0.5% in the volume may be judged as an exact measurement as it corresponds to 0.17% of the relative exactness degree in the length measurement. We have calculated the exact earth volume conversion coefficient by the use of function ratio as per the wet unit weight and the indoor soil quality test as per volume calculated. And then we have found out minor differences as a result of the comparison and analysis with the earth volume conversion coefficient determined by the dry unit weight test as per sand replacement method. This may be judged as a rational design method for the calculation of earth volume conversion coefficient, as well as high reliability of site test as a precision photogrammetry is adopted for volume measurement of the irregular excavating areas.

  • PDF

조금구의 충격계수에 관한 연구 (Study on the Impact Coefficient of the Lifting System)

  • 하대환
    • 기술사
    • /
    • 제34권3호
    • /
    • pp.64-67
    • /
    • 2001
  • In resent the weight of structure is heavier and bigger than before. Engineers use many heavy equipments to erect buildings and bridges. The heavy equipment is very useful to lift any weight. But most engineers do not know the impact of the weight when the equipment lifts the weight. In this study one researched into the impact of the weight in the crane work which lifts the weight in the construction site. Also along the number of pulley sheave the impact of the weight was researched. From the impact field test the impact coefficient of a single pulley sheave crane was 0.65 and the four pulley sheaves crane was 0.13. The result shows that the impact coefficient of a single pulley crane is more than 5 time of the impact coefficient of the four pulley sheaves crane and that engineers must consider the impact effect of the crane work in the construction site.

  • PDF

Critical Multiple Correlation Coefficient for Improving Mean and Variance in Augmenting Hydrologic Samples

  • Heo, Jun-Haeng
    • Korean Journal of Hydrosciences
    • /
    • 제6권
    • /
    • pp.13-22
    • /
    • 1995
  • The augmenting hydrologic data using a correlation procedure has been used to improve the estimates of the mean and variance at the site of interest with short record when one or more near by sites with longer records are available. The variance of the unbiased maximum likelihood estimator of $ derived by Moran based on the multivariate normal distribytion is modified into the form of Matalas and Jacobs for the biveriate normal distribution to get the critical minimum values of the multiple correlation coefficient which give the improvement for estimating the variance at the site of interest. Those values are tabulated for various lengths of short records and the number of sites.

  • PDF

국내 주요도시의 운량데이터를 이용한 전일사 산출 및 비교 (Analysis of Data and Calculation of Global Solar Radiation based on Cloud Data for Major Cities in Korea)

  • 유호천;이관호;박소희
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.17-24
    • /
    • 2008
  • Estimation of typical solar radiation is very important for the calculations concerning many solar applications. But solar radiation measurements are not easily available because of the expensive measuring equipment and techniques required. Accordingly, for regions where no solar radiation is measured, solar radiation need to be estimated using other meteorological data. However, currently in Korea, there is no study on how to do this. In this paper, the global radiation of the six major cities in South Korea where the global radiation is measured using comparatively simple CRM model was calculated compared and analyzed. The comparison between the original coefficient and the site-fitted coefficient for these cities are as follows. Differences between the site-fitted coefficient and the original coefficient for six cities are small. Except for Gwangju, both calculations show strong correlation. In case of Seoul, the $R^2$(coefficient of determination) were 0.747 and 0.749. In case of Busan and Daegu the figures were 0.817, 0.819 and 0.820, 0.821 respectively. For Gwangju, these were 0.618 and 0.622, Thus, the site-fitted coefficients were slightly higher for these four cities. On the other hand, Daejeon and Incheon was reported 0.773, 0.772 and 0.785, 0.783, respectively.

수계 상하류의 유량 및 수질 상관관계 분석 (Analysis of Correlation Relationship for Flow and Water Quality at Up and Down Streams)

  • 장인수;정진경;박기범
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.771-778
    • /
    • 2010
  • The prediction of discharge is very important in water resources management and plan. In this study, we have analyzed discharge data of site at up and down stream in watershed. In order to forecast discharge the regression equations were developed by measuring flow data. Also, to forecast the change of water quality followed by change of inflow the correlation relationship between inflow of the Youngchun site and the Chunhju dam was shown as very high. The forecast of inflow at the Chungju dam would be possible through flow analysis of the Youngchun site. And, it is possible to forecast water quality by flow analysis because the correlation relationship of SS and turbidity followed by change of flow for each station of investigation was very high.

건축물의 지진해석을 위한 연약지반에 묻힌 기초로 인한 지반증폭계수에 대한 저감계수 (Reduction Factor of the Site Coefficient due to the Foundation Embedment in the Soft Soil Layer for the Seismic Analysis of a Building)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제14권4호
    • /
    • pp.1-15
    • /
    • 2010
  • 이 논문에서는 연약지반에 세워진 건축물의 지진해석을 위해서 기준의 지반증폭계수에 대한 기초묻힘으로 인한 저감계수를 산정하는 연구를 비선형 의사 3D 지진해석이 가능한 P3DASS 유한요소 프로그램으로 수행하였다. 지반은 30m 두께로 균질하고 탄성과 점성이 있는 등방성 연약한 지반으로 암반 위에 놓인 것으로 가정하였고, 기초는 반경이 10-70m인 등가원형 강체기초로 기초묻힘은 0, 10, 20, 30m인 경우를 고려하였다. 지진해석은 노두에서 실측한 7개 지진기록의 유효지진가속도를 0.1g로 조정한 후 연약지반 밑 암반에서 지진기록을 생성하여 수행하였다. 연구에 의하면 매우 연약한 지반에 소형기초가 깊게 묻힌 경우 외에는 지반증폭계수가 점진적으로 감소하고 기초크기에 따른 편차도 크지 않은 것으로 평가되어 기초반경 별로 구한 저감계수에 대한 평균에 표준편차를 더한 저감계수를 기초묻힘에 따른 표준저감계수로 산정하였다. 지반증폭계수에 대한 표준저감계수를 실용화와 KBC 등의 기준을 위해 지반의 평균전단파속도와 지반종류에 따라 제안하였다.