• Title/Summary/Keyword: single-tooth implant

Search Result 111, Processing Time 0.023 seconds

A Comparison of Effectiveness of Gracey Curet and Ultrasonic Curet on Subgingival Scaling and Root Planning (치은 연하 치석 제거와 치근면 활택술시 Gracey curet과 Ultrasonic curet의 치석 제거에 효과에 대한 비교 연구)

  • Chung, Suk-Hyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.257-269
    • /
    • 2001
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, Gracey curet and Ultrasonic curet were used on single rooted teeth to conduct subgingval scaling and root planning. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth were extracted from 14 patients being treated at department Periodontology Seoul Advantist dental hospital were used. Total 96 area(4 surface per teeth) were evaluated. 12 teeth treated with Gracey curet were used as the control group and the other 12 teeth treated with Ultrasonic curet were examined for experimental group. The 4 surface of the teeth(buccal, mesial, lingual or palatal, distal) were observed through the stereomicroscope and the images of the surface were captured and saved in CCD. The images were displayed on the monitor and the amount of calculus remained was evaluated by overlapping $10{\times}10$ grid pixel screen produced by Microsoft power point. The results evaluated were as follows 1. There was no statistically significant difference in residual calculus and tooth position following scaling and root planning of all group, but statistically significant correlation with residual calculus, probing depth, instruments and tooth surface. 2. There was statistically significant correlation between residual calculus and probing depth, but no statistically significant difference in residual calculus, tooth surface and tooth position on experimental(Ultrasonic curet) group. 3. There was no statistically significant difference in residual calculus according to the pre-treatment pocket depth and tooth position, but statistically significant correlation with tooth surface. The amount of residual calculus increase with mesial, distal, buccal and lingual(or palatal) surface on control(Gracey curet) group. 4. The Gracey showed better results than ultrasonic curet in mesial and distal surface, and there is significant difference. The results demonstrate that ultrasonic curet alone is inadequate for thorough subgingival debridement and suggest that Ultrasonic curet with Gracey curet should be more effective.

  • PDF

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Initial Changes of Implant Stability from Installation during Early Bone Healing (임플란트 식립 후 초기 안정성의 변화)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.272-279
    • /
    • 2013
  • The concept of implant stability was basically originated from the relative condition of bone-implant interface and has some meanings for evaluation of that interface. In addtion, it has been used for the investigation of initial bone healing process after fixture installation because a degree of micromotion around interface can affect unfavorable clinical results. The purpose of this study is to investigate the mode of initial bone healing from fixture installation through prospective trial. Thirty fixtures were consecutively installed in mandibles of 26 patients with single tooth loss area and then healing abutment were secured for one-stage surgery meothod. Resonance frequency analysis was performed with one week interval during 12 weeks and periapical radiographs were taken at each month. Although marginal bone level change was not shown through observation period (P>0.05), statistical difference of implant stability was shown through 4 and 6 week (P<0.05) and was not shown after 6 week (P>0.05) according to the bone quality. Initial bone healing process is a successive process of bone resorption and favorable bone healing result might be postulated at 4 week interval after installation through RFA.

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

Comparative esthetic evaluation of anterior zone with immediate, early, and delay implantation (전치부 영역 임플란트의 식립 시기에 따른 심미적 평가)

  • Kim, Jung-Hwa;Seo, Seong-Yong;Kim, Na-Hong;Yu, Jung-Hyun;Lee, Dong -Woon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • Purpose: This retrospective study is to evaluate whether the timing of implant placement and the result of esthetic outcomes are related. Materials and Methods: Among the patients who had undergone single implant surgery on anterior area from 2010 to 2013 in Veterans Health Service Medical Center, 34 implants in 27 patients (24 male and 3 female) were selected and categorized into 3 groups according to the timing of placement, which are group D (Delay), group E (Early) and group I (Immediate). Aesthetic indices used included the Pink Esthetic Score (PES). It has 7 variables scores, such as mesial papilla, distal papilla, a level of soft-tissue margin, soft-tissue contour, alveolar process, soft-tissue color, and soft-tissue texture. Each variable ranges from 0 to 2, therefore total 14 points are highest. All patients were received by regular follow-up at least 1-year. One examiner measured PES on the intraoral photos. Each patient was considered as a statistical unit for statistical analysis. Statistical analyses were performed using a commercially available statistical software (SPSS Statistics 21.0, IBM Corp., Armonk, NY, USA). Kruskal-Wallis test was used for inter-group comparisons. Statistical significance was set at P<0.05. Result: Mean score in Group D, Group I, and Group E were $11.5{\pm}1.5$, $11.4{\pm}1.8$, and $11.3{\pm}1.8$ respectively. In Kruskal-Wallis test, there are no differences (P=0.989). Conclusion: In this limited study suggests that clinical aesthetic results can be achieved with all treatment protocols. Finally, various factors can be considered to produce the esthetic results.

CLINICAL STUDY ON THE EFFECT OF WIND INSTRUMENT PLAYING ON PERIODONTAL CONDITIONS (관악기 연주자의 치주상태에 관한 연구)

  • Lee, Won-You;Choi, Seong-Ho;Kim, Sung-Hee
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.390-396
    • /
    • 1994
  • This study investigates the effect of wind instrument playing on the periodontal condition by comparing and analyzing wind instrument players and non-wind instrument players by various clinical paramenters, including periodontal index, bleeding index, simplified oral hygiene index, and non-functional tooth index. The subjects consist of 65 wind instrument players and 31 non-players. The players were divided into 4 groups ; Those who use cup-shaped mouthpieces as Group A, single reed mouthpieces as Group B, double reed mouthieces as Group C, and hole mouthpieces as Group D. Non-players are designated as Group E. The results are as follows ; 1. Periodontal Index Group A recorded $1.2{\pm}0.7$, Group B $1.1{\pm}0.7$, Group C $1.3{\pm}0.5$, Group D $2.1{\pm}0.5$, and Group E $0.9{\pm}0.6$, with no statistically significant differences among the groups. 2. Bleeding Index Group A shwed 0.23, Group B 0.25, Group C 3.0, Group D 0.38, and Group E 0.23, with no statistically significant differences among the groups. 3. Non-functional Tooth Index Group A recorded 2.0, Group B 1.0, Group C 3.0, Group D 0, Group E 0.7, with no statistically significant differences among the groups. 4. Simplified Oral Hygiene Index Buccal sides of maxillary 1st molars, lingual sides of mandibular 1st molars, labial sides of maxillary anterior teeth, and lingual sides of mandibular anterior teeth were investigated, and there was no statistically significant differences among the groups.

  • PDF

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

Receptor activator of nuclear factor kappa-B gene polymorphisms in Iranian periodontitis and peri-implantitis patients

  • Kadkhodazadeh, Mahdi;Baghani, Zahra;Ebadian, Ahmad Reza;Kaghazchi, Zahra;Amid, Reza
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.3
    • /
    • pp.141-146
    • /
    • 2014
  • Purpose: Peri-implantitis and periodontitis are inflammatory and infectious diseases of implant and tooth-supporting tissues. Recently, the role of gene polymorphisms of immune response components in the relevant pathogenesis has been investigated. The present study was the first to evaluate the relationship between two known single nucleotide polymorphisms (SNPs) of the receptor activator of nuclear factor kappa-${\beta}$ (RANK) gene (rs3018362 and rs35211496) in chronic periodontitis and peri-implantitis patients in an Iranian population. Methods: Eighty-one periodontally healthy patients, 38 patients with peri-implantitis, and 74 patients with chronic periodontitis were enrolled in this study. DNA was extracted from blood arm vein samples by using Miller's salting out technique according to the manufacturer's instructions given in the extraction kit. The concentration of DNA samples was measured using a spectrophotometer. The genetic polymorphisms of the RANK gene were evaluated using a competitive allele specific polymerase chain reaction (KBioscience allele specific PCR) technique. Differences in the frequencies of genotypes and alleles in the diseased and healthy groups were analyzed using chi-squared statistical tests (P<0.05). Results: Analysis of rs35211496 revealed statistically significant differences in the expression of the TT, TC, and CC genotypes among the three groups (P=0.00). No statistically significant difference was detected in this respect between the control group and the chronic periodontitis group. The expression of the GG, GA, and AA genotypes and allele frequencies (rs3018362) showed no statistically significant difference among the three groups (P=0.21). Conclusions: The results of this study indicate that the CC genotype of the rs35211496 RANK gene polymorphism was significantly associated with peri-implantitis and may be considered a genetic determinant for peri-implantitis, but this needs to be confirmed by further studies in other populations.