• 제목/요약/키워드: single-pulse source

검색결과 103건 처리시간 0.029초

여과초기에서의 탈착된 입자의 거동 (Role of Detached Particles During Initial Filtration Phase)

  • 김자겸
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

델타변환 무정전전원장치 시스템의 특성 시험 (Test on Characteristics of Delta Conversion UPS System)

  • 지준근
    • 한국산학기술학회논문지
    • /
    • 제6권6호
    • /
    • pp.491-496
    • /
    • 2005
  • 본 논문에서는 일명 델타변환 무정전전원장치(UPS)로서 알려져 있는 3상 라인 인터랙티브 UPS 시스템의 성능 시험에 대해서 다루고 있다. 델타변환 UPS는 종래의 단일 변환 라인 인터랙티브 UPS 시스템에서 직렬 인덕터를 제거하고 직렬 및 병렬 PWM(Pulse Width Modulation) 컨버터를 사용하는 새로운 라인 인터랙티브 UPS 시스템으로 전원 전류를 직접 제어함으로써 UPS 시스템의 입출력 특성들이 상당히 개선되는 것으로 알려져 있다. 여기서는 UPS 시스템의 성능 시험에서 중요한 내용들인 부하시험, 정전/복전시험, 동기절체 시험 등에 대한 결과들을 제시하고 델타변환 UPS 시스템에 대한 전반적인 평가를 한다.

  • PDF

A Stipulation Based Sources Insertion Multilevel Inverter (SBSIMLI) for Waning the Component Count and Separate DC Sources

  • Edwin, Jose S;Titus, S
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1519-1528
    • /
    • 2017
  • The paper proposes a well structured, component count waned single phase multilevel inverter (MLI) topology, which drives three different modules viz. Stipulation Based Sources Insertion (SBSI) module, Level Count Increasing (LCI) module and Inter-Linking H-Bridge (ILHB) module. The SBSI module confronts the number of basic sources needed in series/parallel to achieve required magnitude for any particular level. The LCI possesses an offsetting dc source and opuses to increase the number of levels and the ILHB module links the SBSI and LCI modules. A developed Hybrid Pulse Width Modulation (HPWM) strategy has PWM pulses for the switches of LCI module while the switches of the remaining two modules function at fundamental switching frequency. A fifteen level version of the proposed stipulation based sources insertion MLI (SBSIMLI) topology is simulated in MATLAB R2010a and a prototype of the similar specifications is constructed to validate the performance by experimental results. The comparison between the developed SBSIMLI topology and the competent topologies shows many interesting facts.

High-Frequency Flyback Transformer Linked PWM Power Conditioner with An Active Switched Capacitor Snubber

  • Mun, Sang-Pil;Kim, Soo-Wook;Joo, Seok-Min;Park, Young-Jun
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.7-15
    • /
    • 2008
  • A single active capacitor snubber-assisted soft-switching sinewave pulse modulation utility-interactive power conditioner with a three-winding flyback high frequency transformer link and a bidirectional active power switch in its secondary side has been proposed. With the aid of the switched-capacitor quasi-resonant snubber cell, the high frequency switching devices in the primary side of the proposed DC-to-AC sinewave power inverter can be turned-off with ZVS commutation. In addition to this, the proposed power conditioner in the DCM can effectively take the advantages of ZCS turn-on commutation. Its output port is connected directly to the utility AC power source grid. At the end, the prototype of the proposed HF-UPC is built and tested in experiment. Its power conversion conditioning and processing circuit with a high frequency flyback transformer link is verified and the output sinewave current is qualified in accordance with the power quality guidelines of the utility AC interactive power systems.

공진형 C-dump컨버터에 의한 SRM의 고성능 운전 (High performance operation of SRM by Resonant C-dump Converter)

  • 정균하;윤용호;김세주;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

  • PDF

Efficient Single-Pass Optical Parametric Generation and Amplification using a Periodically Poled Stoichiometric Lithium Tantalate

  • Yu, Nan-Ei;Lee, Yong-Hoon;Lee, Yeung-Lak;Jung, Chang-Soo;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • 제11권4호
    • /
    • pp.192-195
    • /
    • 2007
  • A high-conversion efficiency, nanosecond pulsed optical parametric generation and amplification with repetition rate of 20 kHz based on a periodically poled MgO-doped stoichiometric lithium tantalate was presented. Pumped by a Q-switched $Nd:YVO_4$ laser at 1064 nm with a pumping power of 4.8W, the generated output power was 1.6W for the signal and idler waves, achieving a slope efficiency of 50%. Using a seed source at signal wave the amplified signal output-pulse energy reached $65{\mu}J$. The obtained maximum gain was 72.4 dB.

A New Method for Elimination of Zero-Sequence Voltage in Dual Three-Level Inverter Fed Open-End Winding Induction Motors

  • Geng, Yi-Wen;Wei, Chen-Xi;Chen, Rui-Cheng;Wang, Liang;Xu, Jia-Bin;Hao, Shuang-Cheng
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.67-75
    • /
    • 2017
  • Due to the excessive zero-sequence voltage in dual three-level inverter fed open-end winding induction motor systems, zero-sequence circumfluence which is harmful to switching devices and insulation is then formed when operating in a single DC voltage source supplying mode. Traditionally, it is the mean value instead of instantaneous value of the zero-sequence voltage that is eliminated, through adjusting the durations of the operating vectors. A new strategy is proposed for zero-sequence voltage elimination, which utilizes unified voltage modulation and a decoupled SVPWM strategy to achieve two same-sized equivalent vectors for an angle of $120^{\circ}$, generated by two inverters independently. Both simulation and experimental results have verified its efficiency in the instantaneous value elimination of zero-sequence voltage.

순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발 (Development of Uninterruptible Power Supply with Voltage Sag Restorer Function)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

쌍방향 시동방식의 고속투입스위치 개발 (Development of the Spark-gap Switch with Dual Trigger System)

  • 김맹현;서윤택;박승재;박병락;고의석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

Study on High Efficiency EEFL Backlight inverter for 32-inch LCD TV

  • Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woon;Min, Sook-Kyu;Kim, Hyun-Jin;Jeon, Hyoung-Jun;Kim, Jong-Sun;Mim, Byoung-Woon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.405-407
    • /
    • 2005
  • As the screen size of LCD increases, EEFL(External Electrode Fluorescent Lamp) has been suggested to be applicable as backlight source for LCD . Since the electrodes of EEFL are outside of the tube, EEFL enhances the lifetime compared with CCFL(Cold Cathode Fluorescent Lamp), and a single inverter can drive multiple EEFL tubes of which luminance is uniform Therefore, a compact design can be realized and the cost of EEFL application would be much lower than that of CCFL. Moreover, EEFL inverter has higher efficiency per unit power than CCFL inverter. In this paper, a complementary full-bridge PWM(Pulse Width Modulation) inverter was designed for 32-inch LCD TV backlight which has 20 EEFL tubes and adapted two different driving methods to the EEFL inverter. The validity of this study is confirmed from the experimental results.

  • PDF