• 제목/요약/키워드: single-pulse source

검색결과 103건 처리시간 0.027초

A Method to Avoid Mutual Interference in a Cooperative Spectrum Sharing System

  • Tran, Truc Thanh;Kong, Hyung Yun
    • Journal of Communications and Networks
    • /
    • 제16권2호
    • /
    • pp.110-120
    • /
    • 2014
  • This article proposes a spectrum sharing method which can avoid the mutual interference in both primary and secondary systems. The two systems make them a priority to use two single-dimension orthogonal signals, the real and imaginary pulse amplitude modulation signals, if the primary system is not in outage with this use. A secondary transmitter is selected to be the primary relay and the active secondary source to perform this. This allows a simultaneous spectrum access without any mutual interference. Otherwise, the primary system attempts to use a full two-dimensional signal, the quadrature amplitude modulation signal. If there is no outage with respect to this use, the secondary spectrum access is not allowed. When both of the previous attempts fail, the secondary system is allowed to freely use the spectrum two whole time slots. The analysis and simulation are provided to analyze the outage performance and they validate the considerable improvement of the proposed method as compared to the conventional one.

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

3상 전류형 능동필터의 디지탈 제어 (Digital Control of Three Phase Active Filter System)

  • 황종규;송성학;목형수;최규하;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.431-433
    • /
    • 1995
  • Active Power Filters(APF) have been developed for several years to solve the harmonics disturbance problems on power system networks. This paper studies observer based digital algorithm and PWM technique for three phase current source APF by simulation. Both switching or outside white noises affect seriously at control signal for APF control system. Hence observer algorithm to reduce noises is used. A technique of generation gating patterns for the CSI topologies based on carrier PWM techniques is applied. The requirements imposed on gating signals are satisified by the appropriate combination of single phase switching patterns and short pulse generator.

  • PDF

인젝션 록킹 방법에 의한 펄스 색소레이저의 단일 종모우드 발진 (Single Longitudinal Mode Operation of a Pulsed Dye Laser Injection-seeded with a CW Ring Dye Laser)

  • 김재완;공홍진;한재원;박승남
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.84-89
    • /
    • 1994
  • 연속발진 색소레이저를 시드레이저로 하고, Nd:YAG 레이저로 펌핑하는 인젝션 록킹된 단일 모우드 펄스 색소레이저를 제작하였다. 위상민감 검출법으로 얻은 오차신호로 시드빔과 공진 상태를 유지하도록 공진기 길이를 조절하였을 때 99% 이상의 펄스가 시드레이저의 주파수에 록킹 되었다. 이때 레이저 출력빔의 중심 주파수 요동이 10MHz 이내로 안정되었다. 펄스폭(FWHM)은 6ns이고 선폭은 130 MHz이었다. 50mJ로 펌핑하였을 때 2mJ의 출력을 얻었으며 이때의 첨두출력은 0.33 MW이다.

  • PDF

XeCl 레이저를 이용한 단일 단펄스 분포궤한 색소레이저의 3단 증폭기 특성 (Three-staged amplifier properties of single-short pulsed distributed feedback dye laser using a XeCl laser)

  • 김성훈;이영우;김용평
    • 한국광학회지
    • /
    • 제10권5호
    • /
    • pp.424-429
    • /
    • 1999
  • 본 연구는 XeCl 레이저를 펌핑원으로 사용하여 파장 616nm, 펄스폭 106 ps의 분포궤환 색소레이저(DFDL)의 발진과 증폭특성을 측정하였다. 소광장치를 구성하여 얻은 DFDL 단일펄스의 효과적인 증폭을 위해 3단 증폭기를 사용하였다. 증폭기I,II는 전치증폭단으로서 이득길이 5 nm, 10 nm의 색소셀에 농도6$\times$10-4 [mol/ι](용매: Methanol)의 Rhodamine 610을 이득매질로 사용하였다. 증폭기 I은 2%의 ASE 발생과 1 mJ 이상의 펌핑 에너지에서 10배의 포화증폭율을 가지며, 증폭기 II는 2.5 mJ 이상의 펌핑 에너지에서 single-pass 증폭을 통하여 28배의 포화증폭율과 함께 15%의 ASE 발생이 측정되었으며, 최적 증폭을 위해 회절격자를 이용한 ASE 제거와 double-pass 증폭을 수행하여 45배의 에너지 증폭율을 얻었다. 최종증폭단인 증폭기III은 상.하.좌.우의 위치에서 여기되는 Bethune 셀에 농도 3$\times$10-4 [mol/ι](용매:Ethanol)의 Rhodamine 610을 이득매질로 사용하였으며, single-pass 증폭, double-pass 증폭에서 각각 168.2 $\mu$J과 471$\mu$J의 출력에너지를 얻었다.

  • PDF

1채널 단일광자검출기를 이용한 낮은 광출력의 SWIR(Short Wave Infrared) 3D 라이다 시스템 개발 (Development of SWIR 3D Lidar System with Low Optical Power Using 1 Channel Single Photon Detector)

  • 권오성;이승필;신승민;박민영;반창우
    • 한국산업융합학회 논문집
    • /
    • 제25권6_3호
    • /
    • pp.1147-1154
    • /
    • 2022
  • Now that the development of autonomous driving is progressing, LiDAR has become an indispensable element. However, LiDAR is a device that uses lasers, and laser side effects may occur. One of them is the much-talked-about eye-safety, and developers have been satisfying this through laser characteristics and operation methods. But eye-safety is just one of the problems lasers pose. For example, irradiating a laser with a specific energy level or higher in a dusty environment can cause deterioration of the dust particles, leading to a sudden explosion. For this reason, the dust ignition proof regulations clearly state that "a source with a pulse period of less than 5 seconds is considered a continuous light source, and the average energy does not exceed 5 mJ/mm 2 or 35 mW" [2]. Energy of output optical power is limited by the law. In this way, the manufacturer cannot define the usage environment of the LiDAR, and the development of a LiDAR that can be used in such an environment can increase the ripple effect in terms of use in application fields using the LiDAR. In this paper, we develop a LiDAR with low optical power that can be used in environments where high power lasers can cause problems, evaluate its performance. Also, we discuss and present one of the directions for the development of LiDAR with laser power limited by dust ignition proof regulations.

Performance Analysis of Spiral Axicon Wavefront Coding Imaging System for Laser Protection

  • Haoqi Luo;Yangliang Li;Junyu Zhang;Hao Zhang;Yunlong Wu;Qing Ye
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.355-365
    • /
    • 2024
  • Wavefront coding (WFC) imaging systems can redistribute the energy of an interference laser spot on an image plane sensor by wavefront phase modulation and reduce the peak intensity, realizing laser protection while maintaining imaging functionality by leveraging algorithmic post-processing. In this paper, a spiral axicon WFC imaging system is proposed, and the performance for laser protection is investigated by constructing a laser transmission model. An Airy disk on an image plane sensor is refactored into a symmetrical hollow ring by a spiral axicon phase mask, and the maximum intensity can be reduced to lower than 1% and single-pixel power to 1.2%. The spiral axicon phase mask exhibits strong robustness to the position of the interference laser source and can effectively reduce the risk of sensor damage for an almost arbitrary lase propagation distance. Moreover, we revealed that there is a sensor hazard distance for both conventional and WFC imaging systems where the maximum single-pixel power reaches a peak value under irradiation of a power-fixed laser source. Our findings can offer guidance for the anti-laser reinforcement design of photoelectric imaging systems, thereby enhancing the adaptability of imaging systems in a complex laser environment. The laser blinding-resistant imaging system has potential applications in security monitoring, autonomous driving, and intense-laser-pulse experiments.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계 (A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED)

  • 김준환;유기연;송예은;유찬영;장윤채;무하마드 리아즈;케이 뜨웨 툰;아메드 알리;최승호
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

디지탈 브리지형 인버터로 구동되는 3상유도전동기의 LC 필터에 의한 전류 및 전력 파형 개선 (The Current and Power Waveform Improvement of a $3{\Phi}$ Induction Motor with LC Filter Driven by a Digital Bridge Inverter)

  • 정주윤;박진길;강창남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.553-555
    • /
    • 1996
  • This paper concerns with a method to improve the current and power waveforms of the variable speed $3{\Phi}$ AC motor system driven by the single-pulse PWM, and the current waveforms and $3{\Phi}$ power waveforms are analyzed by FFT under various running conditions. By the performance analysis through the experiments, the following results have been obtained. AC source of pseudo sine waveform can be obtained from the modulated alternating square voltage by means of the well designed LC filter. It is confirmed that current waveforms and $3{\Phi}$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order. Especially, current waveforms and $3{\Phi}$ power waveforms tan be much improved at low frequency domain. $3{\Phi}$ power waveforms have a smatter ripple and bigger power by utilizing the high order low pass LC filter than that of lower order. Also, the running condition of $3{\Phi}$ AC motor is good at low frequency domain.

  • PDF