• Title/Summary/Keyword: single wire

Search Result 335, Processing Time 0.028 seconds

Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(I)-At the Shockless Condition- (개방형 원심회전차의 내부유동장에 관한 실험적 연구(1)-무충돌 유입조건에서-)

  • 김성원;조강래
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2261-2270
    • /
    • 1995
  • Flow patterns were measured in an unshrouded centrifugal impeller. The flow rate in measurements was fixed at the value corresponding to a nearly zero incidence at the blade inlet. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes from the inlet to the outlet of the impeller rotating at 700rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were calculated from the measured values. From the measured data, the primary/secondary flows, the leakage flows, the wake-jet flows, static pressure distribution on blade surfaces and the wake production mechanism in the impeller passage were investigated.

Fatigue Life Properties of Messenger Wire with Service Environments (가설환경에 따른 조가선의 피로수명 특성)

  • 김용기;장세기;조성일
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.21-28
    • /
    • 2003
  • Environment-dependent fatigue life of Cu-Cd alloy wires used as messenger wires was investigated. Tensile test results showed the decrease of tensile strength and elongation of messenger wires by 3.7% and 16.8%, respectively, in used specimens when compared to new ones. Messenger wires used at industrial region for 26 yeras showed 35∼50% decrease in fatigue life, which is partly due to the in stress concentrations by formation of corrosion products at the surface. Single wires showed better fatigue properties than stranded wires, especially at low cycle regions with higher stresses. Stranded wires showed shorter fatigue lives than single wires because of friction between wires by surface contact. Service life of messenger wires was dependent upon the environments which they were exposed to. SO$_2$ and humidity deteriorated the fatigue properties by environmental degradation.

A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips (수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계)

  • Han, Seung-Kyu;Roh, Si-Young;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF

밀리미터파 레이다 시스템을 이용한 전력선 검출

  • Kang, Gum-Sil;Yong, Sang-Soon;Kang, Song-Doug;Kim, Jong-Ah;Chang, Young-Jun
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.242-250
    • /
    • 2004
  • This paper describes the detection method of wire-like obstacles using millimeter-wave radar system. Passive sensor like CCD camera can be used for the detection of high power electric cables on the hills or mountains and it can give very good quality of obstacle target information. But this system is very limited to use by bad weather condition. The detection capability for different diameters of wire targets using millimeter radar system have been accomplished. To simulate the target on the moving helicopter, rotating targets are used with fixed radar system. In the experiment 11mm, 16mm and 22mm diameter of wires have been detected in single, two and three wires in one position. The detected signal from single wire was very clear on gray level image. Three wires placed very closely together could be recognized in range, cross range image plane. For two and three wires, blur effect due to mutual scattering effect is observed.

  • PDF

Comparison between Intramedullary Nailing and Percutaneous K-Wire Fixation for Fractures in the Distal Third of the Metacarpal Bone

  • Moon, Sung Jun;Yang, Jae-Won;Roh, Si Young;Lee, Dong Chul;Kim, Jin Soo
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.768-772
    • /
    • 2014
  • Background To compare clinical and radiographic outcomes between intramedullary nail fixation and percutaneous K-wire fixation for fractures in the distal third portion of the metacarpal bone. Methods A single-institutional retrospective review identified 41 consecutive cases of metacarpal fractures between September 2009 and August 2013. Each of the cases met the inclusion criteria for closed, extra-articular fractures of the distal third of the metacarpal bone. The patients were divided by the method of fixation (intramedullary nailing or K-wire). Outcomes were compared for mean and median total active motion of the digit, radiographic parameters, and period until return to work. Complications and symptoms were determined by a questionnaire. Results During the period under review, 41 patients met the inclusion criteria, and the fractures were managed with either intramedullary nailing (n=19) or percutaneous K-wire fixation (n=22). The mean and median total active range of motion and radiographic healing showed no statistically significant difference between the two groups. No union failures were observed in either group. The mean operation time was shorter by an average of 14 minutes for the percutaneous K-wire fixation group. However, the intramedullary nailing group returned to work earlier by an average of 2.3 weeks. Complications were reported only in the K-wire fixation group. Conclusions Intramedullary nailing fixation is advisable for fractures in the distal third of the metacarpal bone. It provides early recovery of the range of motion, an earlier return to work, and lower complication rates, despite potentially requiring a wire removal procedure at the patient's request.

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

A Study on the Axial Stiffness Prediction of Stand Using Analysis of Variance (분산분석을 이용한 스트랜드의 축강성 예측에 관한 연구)

  • Park, Yong-Dae;Yang, Won-Ho;Heo, Seong-Pil;Seong, Gi-Deuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.127-134
    • /
    • 2001
  • Wire ropes are widely used in cable car, suspension bridge and elevator, etc. and composed of single or multi-layer strands. It is difficult to find out the characteristics of a strand or wire rope because of complicated geometry and contact condition. In this study, the axial stiffness is evaluated using finite element method and reliable finite element analysis model is presented, taking into consideration the convergence on the length. The axial stiffness predictive equation of a strand is developed using analysis of variance, which can be applicable for characterizing the relationship between load and displacement when the strand configuration is determined.

Calculation of DC Characteristics of Stacked BSCCO Wires under Variable External Magnetic field (수치해석을 이용한 BSCCO 적층 선제들의 외부자장 변화에 따른 DC 통전 특성 계산)

  • Lim, Hyoung-Woo;Kang, Myung-Hun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.53-55
    • /
    • 2007
  • This paper has presented the numerical calculation of fundamental characteristics of the HTS wire by using commercial software. Numerical calculation of the HTS wire's characteristics is able to reduce the time and effort which need to be exerted to obtain hose values experimentally. Results of numerical calculation, such as, critical current of he single and the multi-slacked wire under external magnetic field, were compared with that of experimental results.

  • PDF

Ductility of concrete slabs reinforced with low-ductility welded wire fabric and steel fibers

  • Tuladhar, Rabin;Lancini, Benjamin J.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.4
    • /
    • pp.449-461
    • /
    • 2014
  • The use of low-ductility welded wire fabric (WWF) as a main tensile reinforcement in concrete slabs compromises the ductility of concrete structures. Lower ductility in concrete structures can lead to brittle and catastrophic failure of the structures. This paper presents the experimental study carried out on eight simply supported one-way slabs to study the structural behavior of concrete slabs reinforced with low-ductility WWF and steel fibers. The different types of steel fibers used were crimped fiber, hooked-end fiber and twincone fiber. The experimental results show that the ductility behavior of the slab specimens with low-ductility reinforcement was significantly improved with the inclusion of $40kg/m^3$ of twincone fiber. Distribution of cracks was prominent in the slabs with twincone fiber, which also indicates the better distribution of internal forces in these slabs. However, the slab reinforced only with low-ductility reinforcement failed catastrophically with a single minor crack and without appreciable deflection.