• Title/Summary/Keyword: single point calibration

Search Result 35, Processing Time 0.028 seconds

Design and Implementation of Low Power Touch Screen Controller for Mobile Devices (모바일용 저전력 터치 스크린 제어 회로 설계 및 구현)

  • Park, Sang-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.279-283
    • /
    • 2012
  • In is paper, we design and implement the low power, high speed touch screen controller that calculates and outputs the coordinate of touch point on the touch screen of mobile devices. The system clock is 10HMz, the number of input channels is 21, standby current is $20{\mu}A$, dynamic range of input is 140pF~400pF and the response time is 0.1ms/frame. It contains the power management unit for low power, automatic impedance calibration unit in order to adapt to humidity, temperature and evaluation board, adjacent key and pattern interference suppression unit, serial interface unit of I2C and SPI. The function and performance is verified by using FPGA and $0.18{\mu}m$ CMOS standard process. The implemented touch screen is designed for using in the double layer ITO(Indium Thin Oxide) module with diamond pattern and single layer ITO module for cost-effective which are applied to mobile phone or smart remote controller.

Reconstruction of a 3D Model using the Midpoints of Line Segments in a Single Image (한 장의 영상으로부터 선분의 중점 정보를 이용한 3차원 모델의 재구성)

  • Park Young Sup;Ryoo Seung Taek;Cho Sung Dong;Yoon Kyung Hyun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.4
    • /
    • pp.168-176
    • /
    • 2005
  • We propose a method for 3-dimensionally reconstructing an object using a line that includes the midpoint information from a single image. A pre-defined polygon is used as the primitive and the recovery is processed from a single image. The 3D reconstruction is processed by mapping the correspondence point of the primitive model onto the photo. In the recent work, the reconstructions of camera parameters or error minimizing methods through iterations were used for model-based 3D reconstruction. However, we proposed a method for the 3D reconstruction of primitive that consists of the segments and the center points of the segments for the reconstruction process. This method enables the reconstruction of the primitive model to be processed using only the focal length of various camera parameters during the segment reconstruction process.

Real-Time Reduction Software for Slitless Spectral Image

  • Ji, Tae-Geun;Pak, Soojong;Shin, Suhyun;Byeon, Seoyeon;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.71.3-71.3
    • /
    • 2019
  • For slitless spectroscopy, we have installed the Volume Phase Holographic (VPH) gratings in the filter wheel of the SQUEAN on the 2.1m telescope at McDonald Observatory in Texas, United States. This system can effectively take spectra and monitor the variabilities of many sources, such as quasi-stellar objects, supernovae, and active galactic nuclei. On the single image frame, there are many spectra of the point sources. Therefore, a target extraction needs to trace along the tilted dispersion and to minimize the confusions by other sources. We present a real-time reduction software that has the functions with spectra extraction and wavelength calibration.

  • PDF

Shear response estimate for squat reinforced concrete walls via a single panel model

  • Massone, Leonardo M.;Ulloa, Marco A.
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.647-665
    • /
    • 2014
  • Squat reinforced concrete walls require enough shear strength in order to promote flexural yielding, which creates the need for designers of an accurate method for strength prediction. In many cases, especially for existing buildings, strength estimates might be insufficient when more accurate analyses are needed, such as pushover analysis. In this case, estimates of load versus displacement are required for building modeling. A model is developed that predicts the shear load versus shear deformation of squat reinforced concrete walls by means of a panel formulation. In order to provide a simple, design-oriented tool, the formulation considers the wall as a single element, which presents an average strain and stress field for the entire wall. Simple material constitutive laws for concrete and steel are used. The developed models can be divided into two categories: (i) rotating-angle and (ii) fixed-angle models. In the first case, the principal stress/strain direction rotates for each drift increment. This situation is addressed by prescribing the average normal strain of the panel. The formation of a crack, which can be interpreted as a fixed principal strain direction is imposed on the second formulation via calibration of the principal stress/strain direction obtained from the rotating-angle model at a cracking stage. Two alternatives are selected for the cracking point: fcr and 0.5fcr (post-peak). In terms of shear capacity, the model results are compared with an experimental database indicating that the fixed-angle models yield good results. The overall response (load-displacement) is also reasonable well predicted for specimens with diagonal compression failure.

Estimation of Human Height and Position using a Single Camera (단일 카메라를 이용한 보행자의 높이 및 위치 추정 기법)

  • Lee, Seok-Han;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.20-31
    • /
    • 2008
  • In this paper, we propose a single view-based technique for the estimation of human height and position. Conventional techniques for the estimation of 3D geometric information are based on the estimation of geometric cues such as vanishing point and vanishing line. The proposed technique, however, back-projects the image of moving object directly, and estimates the position and the height of the object in 3D space where its coordinate system is designated by a marker. Then, geometric errors are corrected by using geometric constraints provided by the marker. Unlike most of the conventional techniques, the proposed method offers a framework for simultaneous acquisition of height and position of an individual resident in the image. The accuracy and the robustness of our technique is verified on the experimental results of several real video sequences from outdoor environments.

Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera (저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정)

  • Kim, Seo Woo;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2018
  • The precision of the vibration-sensors, contact or non-contact types, is usually satisfactory for the practical measurement applications, but a sensor is confined to the measurement of a point or a direction. Although the precision and frequency span of the low-cost camera are inferior to these sensors, it has the merits in the cost and in the capability of simultaneous measurement of a large vibrating area. Furthermore, a camera can measure multi-degrees-of-freedom of a vibrating object simultaneously. In this study, the calibration method and the dynamic characteristics of the low-cost machine vision camera as a sensor are studied with a demonstrating example of the two-dimensional vibration of a cantilever beam. The planar image of the camera shot reveals two rectilinear and one rotational motion. The rectilinear vibration motion of a single point is first measured using a camera and the camera is experimentally calibrated by calculating error referencing the LDV (Laser Doppler Vibrometer) measurement. Then, by measuring the motion of multiple points at once, the rotational vibration motion and the whole vibration motion of the cantilever beam are measured. The whole vibration motion of the cantilever beam is analyzed both in time and frequency domain.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Fundamental Matrix Estimation and Key Frame Selection for Full 3D Reconstruction Under Circular Motion (회전 영상에서 기본 행렬 추정 및 키 프레임 선택을 이용한 전방향 3차원 영상 재구성)

  • Kim, Sang-Hoon;Seo, Yung-Ho;Kim, Tae-Eun;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.10-23
    • /
    • 2009
  • The fundamental matrix and key frame selection are one of the most important techniques to recover full 3D reconstruction of objects from turntable sequences. This paper proposes a new algorithm that estimates a robust fundamental matrix for camera calibration from uncalibrated images taken under turn-table motion. Single axis turntable motion can be described in terms of its fixed entities. This provides new algorithms for computing the fundamental matrix. From the projective properties of the conics and fundamental matrix the Euclidean 3D coordinates of a point are obtained from geometric locus of the image points trajectories. Experimental results on real and virtual image sequences demonstrate good object reconstructions.

Robust pupil detection and gaze tracking under occlusion of eyes

  • Lee, Gyung-Ju;Kim, Jin-Suh;Kim, Gye-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.11-19
    • /
    • 2016
  • The size of a display is large, The form becoming various of that do not apply to previous methods of gaze tracking and if setup gaze-track-camera above display, can solve the problem of size or height of display. However, This method can not use of infrared illumination information of reflected cornea using previous methods. In this paper, Robust pupil detecting method for eye's occlusion, corner point of inner eye and center of pupil, and using the face pose information proposes a method for calculating the simply position of the gaze. In the proposed method, capture the frame for gaze tracking that according to position of person transform camera mode of wide or narrow angle. If detect the face exist in field of view(FOV) in wide mode of camera, transform narrow mode of camera calculating position of face. The frame captured in narrow mode of camera include gaze direction information of person in long distance. The method for calculating the gaze direction consist of face pose estimation and gaze direction calculating step. Face pose estimation is estimated by mapping between feature point of detected face and 3D model. To calculate gaze direction the first, perform ellipse detect using splitting from iris edge information of pupil and if occlusion of pupil, estimate position of pupil with deformable template. Then using center of pupil and corner point of inner eye, face pose information calculate gaze position at display. In the experiment, proposed gaze tracking algorithm in this paper solve the constraints that form of a display, to calculate effectively gaze direction of person in the long distance using single camera, demonstrate in experiments by distance.

Multi-aperture Photometry Pipeline for DEEP-South Data

  • Chang, Seo-Won;Byun, Yong-Ik;Kim, Myung-Jin;Moon, Hong-Kyu;Yim, Hong-Suh;Shin, Min-Su;Kang, Young-Woon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.56.2-56.2
    • /
    • 2016
  • We present a multi-aperture photometry pipeline for DEEP-South (Deep Ecliptic Patrol of the Southern Sky) time-series data, written in C. The pipeline is designed to do robust high-precision photometry and calibration of non-crowded fields with a varying point-spread function, allowing for the wholesale search and characterization of both temporal and spatial variabilities. Our time-series photometry method consists of three parts: (i) extracting all point sources with several pixel/blind parameters, (ii) determining the optimized aperture for each source where we consider whether the measured flux within the aperture is contaminated by unwanted artifacts, and (iii) correcting position-dependent variations in the PSF shape across the mosaic CCD. In order to provide faster access to the resultant catalogs, we also utilize an efficient indexing technique using compressed bitmap indices (FastBit). Lastly, we focus on the development and application of catalog-based searches that aid the identification of high-probable single events from the indexed database. This catalog-based approach is still useful to identify new point-sources or moving objects in non-crowded fields. The performance of the pipeline is being tested on various sets of time-series data available in several archives: DEEP-South asteroid survey and HAT-South/MMT exoplanet survey data sets.

  • PDF