• Title/Summary/Keyword: single photon emission computed tomography (SPECT)

Search Result 128, Processing Time 0.029 seconds

Accumulation of Thallium-201 in Hemorrhagic Cerebral Infarction (Thallium-201 brain SPECT에서 양성 소견을 보인 출혈성 뇌경색)

  • Lee, Ki-Yeol;Kim, Kyung-Min;Choe, Jae-Gol;Chung, Yong-Gu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.337-340
    • /
    • 1999
  • Thallium-201 brain SPECT is utilized in the diagnosis of brain tumor especially in cases where CT or MRI findings alone cannot differentiate malignant lesion from benign. Recently we came across two cases of positive T1-201 brain SPECT in clinically suspected brain tumor patients that turned out to be hemorrhagic cerebral infarction instead on biopsy. The findings in these cases demonstrate that thallium-201 accumulation may occur by the breakdown of the blood-brain barrier and phagocytic cell infiltration in the liquefaction stage of infarction.

  • PDF

Renal Manifestations and Imaging Studies of Kawasaki Disease (가와사키 질환에서의 신증상과 영상 검사 소견)

  • Oh, Ji Young;Park, Se Jin;Kim, Sun Jung;Jang, Gwang-Cheon;Kim, Uria;Shin, Jae Il;Kim, Kee Hyuck
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.86-91
    • /
    • 2013
  • Purpose: The aim of this study was to verify renal inflammation following Kawasaki disease (KD) using single photon emission computed tomography along with Technetium-99m dimercaptosuccinic acid scintigraphy (DMSA renal SPECT). Methods: From March 2011 to October 2011, 15 patients diagnosed with KD at the National Health Insurance System Ilsan Hospital were enrolled in the study. All patients underwent DMSA renal SPECT to evaluate renal involvement during the acute phase of KD. Urine ${\beta}2$-microglobulin (${\beta}2$-MG), a marker of renal proximal tubular dysfunction, was also measured to assess renal damage. Results: All 15 patients had normal renal function test results. However, microscopic hematuria and pyuria were observed in 13% and 33% of the patients, respectively. Moreover, urine ${\beta}2$-MG was elevated in 46% of the patients. In addition, patients were divided into two groups based on ${\beta}2$-MG level: those with an increased ${\beta}2$-MG level, and those with a normal ${\beta}2$-MG level. No significant differences were found between these two groups in clinical characteristics, laboratory, sonography, and echocardiography findings. All patients' DMSA renal SPECT scans were normal. Conclusion: Our study showed that mild abnormalities in the urinalysis and elevated urine ${\beta}2$-MG were the only findings of renal involvement in KD. However, no aggressive renal manifestations were detected on DMSA renal SPECT.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.

The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography (근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성)

  • Shin, Duk-Seop;Na, Ho Dong;Park, Jae Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.509-518
    • /
    • 2019
  • Purpose: Lymph node metastasis is a very important prognostic factor for all skin cancers and some sarcomas. A sentinel lymph node (SLN) biopsy is the most useful technique for identifying SLNs. Recently, a new generation of diagnostic tools, such as single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) enabled the detection of SLNs. This study compared the efficacy of PET/CT for detecting lymph node metastases with a SLN biopsy in a single medical center. Materials and Methods: From 2008 to 2018, 72 skin cancers of sarcoma patients diagnosed with some lymph node involvement in a whole body PET/CT reading were assessed. Patients suspected of lymph node metastasis were sent to biopsy and those suspected to be reactive lesions were observed. The analysis was performed retrospectively using the medical records, clinical information, PET/CT readings, and pathology results. Results: The age of patients ranged from 14 to 88 years and the mean follow-up period was 2.4 years. Twenty-two patients were suspected of a lymph node metastasis and confirmed. The sensitivity, specificity, positive predictive value and negative predictive value of PET/CT images in sarcoma and non-sarcoma tumors were increased significantly when the expert's findings were considered together. Conclusion: PET/CT is effective in detecting lymph node metastases.

Comparison of planar scintigraphy and bone SPECT with clinical findings and other imaging modalities in temporomandibular disorder patients (측두하악관절장애 환자에서의 평면 골 스캔 및 Bone SPECT 소견과 임상적 및 영상학적 소견과의 비교)

  • Jeong Hee-Jeong;Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.91-97
    • /
    • 2004
  • Purpose : This study was performed to evaluate the diagnostic value of both planar and SPECT imagings by comparing the results with the clinical and other imaging modalities findings. Materials and Methods: A total of 578 joints with TMJ complaints were examined using planar scintigraphy and SPECT. The planar scintigraphy and SPECT findings were analyzed and compared to the clinical findings of pain, clicking, crepitus and limitation of mouth opening. Moreover we compared the accuracy of the planar scintigraphy and SPECT methods with the one of the panoramic, transcranial, tomographic and MR imaging methods. Results: The planar scintigraphy and SPECT methods showed a high sensitivity of 0.76-0.84 and low specificity of 0.25-0.45 toward the clinical findings: pain, clicking, crepitus and mouth opening restriction. Simple radionuclide uptake ratio was high in each group of patients with pain, crepitus, limitation of mouth opening (p < 0.05) complaints, in each group with positive bone changes on panoramic, transcranial or tomographic images, and in disc displaced group. Conclusion: Although both planar and SPECT imagings have limited specificity, these techniques are sensitive for detection of internal derangement of the TMJ.

  • PDF

Diagnosing Symptomatic Accessory Tarsal Bones Using SPECT/CT (SPECT/CT를 이용한 증후성 족부 부골의 진단)

  • Kim, Ryuh-Sup;Kang, Joon-Soon;Kim, Young-Tae;Kim, Bom-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.4
    • /
    • pp.212-216
    • /
    • 2011
  • Purpose: This study was designed to analyze the usefulness of Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) in diagnosing symptomatic accessory tarsal bones. Materials and Methods: Twenty four feet (16 patients) with symptomatic accessory navicular and/or os trigonum, who agreed to take SPECT/CT, were included in this study. Fifteen feet had accessory navicular, five had os trigonum, and four had both. According to the uptake in the SPECT/CT, 11 feet were classified into high and 13 into low uptake groups. The low uptake group was treated non-operatively, while the high uptake group received operations when initial conservative management failed. A modified Kidner procedure was performed for accessory navicular and arthroscopic excision was done for os trigonum. After a mean follow-up of 6.8 (range, 3~13) months, the American Orthopaedic Foot and Ankle Society (AOFAS) score and the Visual Analogue Scale (VAS) for pain were compared. Results: Patients in the high uptake group had a higher initial mean VAS score ($7.0{\pm}0.8$ vs $2.2{\pm}0.9$, p<0.05) and a lower initial mean AOFAS score ($45.9{\pm}9.2$ vs $83.9{\pm}4.2$, p<0.05) compared to the low uptake group. All patients in the low uptake group improved after non-operative treatment. Seven patients underwent operations and had a decreased VAS ($1.6{\pm}0.5$) and an increased AOFAS score ($88.3{\pm}1.8$) at the last follow-up. Four patients in the high uptake group demonstrated erratic symptoms. Conclusion: SPECT/CT can be a useful diagnostic tool and helpful in designing treatment plans for symptomatic accessory navicular and os trigonum.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

Recent Advances in Nuclear Medicine Imaging Instrumentation (핵의학 영상기기의 최근 진보)

  • Jung, Jin-Ho;Choi, Yong;Hong, Key-Jo;Min, Byung-Jun;Hu, Wei;Kang, Ji-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF