• 제목/요약/키워드: single particle

검색결과 898건 처리시간 0.036초

Impacts of Limestone Multi-particle Size on Production Performance, Egg Shell Quality, and Egg Quality in Laying Hens

  • Guo, X.Y.;Kim, I.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권6호
    • /
    • pp.839-844
    • /
    • 2012
  • This experiment was conducted to evaluate the effects of single or multi-particle size limestone on the egg shell quality, egg production, egg quality and feed intake in laying hens. A total of 280 laying hens (ISA brown) were used in this 10-wk trial. Laying hens were randomly assigned to 4 treatments with 14 replications per treatment and 5 adjacent cages as a replication (hens were caged individually). The experimental treatments were: i) L, basal diet+10% large particle limestone; ii) LS1, basal diet+8% large particle limestone+2% small particle limestone; iii) LS2, basal diet+6% large particle limestone+4% small particle limestone; iv) S, basal diet+10% small particle limestone. The egg production was unaffected by dietary treatments. The egg weight in S treatment was lighter than other treatments (p<0.05). The egg specific gravity in S treatment was lower than other treatments (p<0.05). The eggshell strength and eggshell thickness in S treatment were decreased when compared with other dietary treatments (p<0.05). The laying hens in LS1 and LS2 treatment had a higher average feed intake than the other two treatments (p<0.05). Collectively,the dietary multi-particle size limestone supplementation could be as efficient as large particle size limestone.

Full Cone Type 스월노즐에서 단일분무와 이중분무의 중첩영역에 대한 충격력 평가 (Evaluation of the Impact Force on the Single Spray and Overlap Region of Twin Spray in Full Cone Type Swirl Nozzle)

  • 김태현;성연모;정흥철;김덕줄;최경민
    • 한국분무공학회지
    • /
    • 제16권1호
    • /
    • pp.27-36
    • /
    • 2011
  • The impact force on the single and overlap region of twin spray was experimentally evaluated using visualization method in full cone type swirl nozzle spray. Visualization of spray was conducted to obtain the spray angle and breakup process. The photography/imaging technique, based on Particle Image Velocimetry (PIV) using high-speed camera, was adopted for the direct observation of droplet motion and axial velocity measurement, respectively. Droplet size was measured by Particle Motion Analyze System (PMAS). The purpose of this study is to provide fundamental information of spray characteristics, such as impact force, for higher etching factor in the practical wet etching system. It was found that the spray angle, axial velocity and impact force were increased with increasing the nozzle pressure while droplet size decreased with increasing the nozzle pressure. Droplet size increased as the distance from nozzle tip was decreased. The impact force of twin spray in the overlap region was about 63.29, 67.02, 52.41% higher than that of single spray at 40, 50 and 60 mm of nozzle pitch, respectively. Also, the nozzle pitch was one of the important factors in the twin spray characteristics.

실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성 (Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences)

  • 김정훈;이기영
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

Single Particle Irradiation System to Cell (SPICE) at NIRS

  • Yamaguchi, Hiroshi;Ssto, Yukio;Imaseki, Hitoshi;Yasuda, Nakahiro;Hamano, Tsuyoshi;Furusawa, Yoshiya;Suzuki, Masao;Ishikawa, Takehiro;Mori, Teiji;Matsumoto, Kenichi;Konishi, Teruaki;Yukawa, Masae;Soga, Fuminori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.267-268
    • /
    • 2002
  • Microbeam is a new avenue of radiation research especially in radiation biology and radiation protection. Selective irradiation of an ionizing particle to a targeted cell organelle may disclose such mechanisms as signal transaction among cell organelles and cell-to-cell communication in the processes toward an endpoint observed. Bystander effect, existence of which is clearly evidenced by application of the particle microbeam to biological experiments, suggests potential underestimation in the conventional risk estimation at low particle fluence rates, such as environment of space radiations in ISS (International Space Station). To promote these studies we started the construction of our microbeam facility (named as SPICE) to our HVEE Tandem accelerator (3.4 MeV proton and 5.1 MeV $^4$He$\^$2+/). For our primary goal, "irradiation of single particle to cell organelle within a position resolution of 2 micrometer in a reasonable irradiation time", special features are considered. Usage of a triplet Q magnet for focussing the beam to submicron of size is an outstanding feature compared to facilities of other institutes. Followings are other features: precise position control of cell dish holder, design of the cell dish, data acquisition of microscopic image of a cell organelle (cell nucleus) and data processing, a reliable particle detection, soft and hard wares to integrate all these related data, to control and irradiate exactly determined number of particles to a targeted spot.

  • PDF

Theoretical Study on Magnetic Field Application for Fine Particle Capture

  • Huang, Shan;Park, Haewoo;Jo, Youngmin
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.45-51
    • /
    • 2014
  • Fine particle capture is facing a challenge since traditional filtration which relies on the combination of impaction, interception, diffusion has a limited efficiency for fine particle capture particularly in size from 0.1 to $0.5{\mu}m$. This paper reviewed the collection efficiency of above mechanisms, as well as magnetic mechanisms for ferromagnetic particles, and mainly studied the influencing factors of magnetic filtration. Filtration velocity, magnetic field intensity and fiber size were found to be the most important parameters for magnetic filtration.

고부피분율 SiC분말 예비성형체의 제조공정과 기계적특성 (Fabrication Process and Mechanical Properties of High Volume Fraction SiC Particle Preform)

  • 전경윤
    • 한국분말재료학회지
    • /
    • 제7권1호
    • /
    • pp.27-34
    • /
    • 2000
  • The fabrication process and mechanical properties of SiC particle prefrrms with high volume fraction ranged 50∼71% were investigated to make metal matrix composites for possible applications as heat sinks in electronic packares. The SiC particle preforms with 50∼71vol% of reinforcement were fabricated by a new modified process named ball milling and pressing method. The SiC particle performs were fabricated by ball milling of SiC particles with single sized of 48${\mu}$m in diameter or two different size of 8${\mu}$m and 48${\mu}$min diameter, with collodal SiO2 as inorgnic binder in distilled water, and the mixed slurries were cold pressed for consolidation into final prefom. The compressive strengths og calcined SiC particle prefoms increased from 20MPa to 155MPa with increasing the content of inorganis binder, temperature and time for calcination. The increase of compressive strength of SiC particle bridge the interfaces of two neighboring SiC particles.

  • PDF

황사의 오염원분류포 개발을 위한 개별입자분석 (Individual Particle Analysis for Developing a Source Profile of Yellow Sands)

  • 강승우;김동술
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.565-572
    • /
    • 2000
  • To quantitatively estimate mass contribution of long-range transported yellow sand, their sources should be separated independently from various local soil sources having similar elemental compositions. While it is difficult to estimate total mass loadings of pure yellow sand by traditional bulk analysis, it can be clearly solved by an particle-by-particle analysis. To perform this study, two yellow sand samples and three local soil samples were collected by a mini-volume sampler. These samples were three analyzed using a scanning electron microscope(SEM) equipped with an energy dispersive x-ray analyser (EDX) was used to obtain basic chemical information of individual yellow san particles. A total of 19 elements in a single particle were measured to develop a source profile with newly created homogeneous particle classes (HPCs) as chemical variables. The present study showed that the yellow sand samples as well as three local soil samples were characterized with reasonably well created HPCs. Finally the mass fraction of each HPC in each sample was calculated and then compared each other.

  • PDF

미세 입자 조작 기구의 제작 및 실험 (Fabrication and Experiment of Micro Particle Manipulator)

  • 박재형;김용권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권3호
    • /
    • pp.136-143
    • /
    • 2001
  • A micro particle manipulator, which is devised for trapping particles at fixed positions by negative dielectrophoretic force (DEP force), has been fabricated and experimented. It is composed of square type electrode arrays fabricated by nickel electroplating with the height of 28 ${\mu}m$. To improve the quality of electroplated nickel electrodes, plating conditions have been optimized. Micro particles used in this study are polystyrene spheres and their to the specific position and trapped. The DEP force along the moving path of the particles has been estimated by the motion equation of a single particle. The displacement of a particle with an elapsed time was measured using a high-speed camera (1000 frames/sec). The velocity and acceleration of the particle were calculated from the measured data. The DEP force acting on the particle was estimated.

  • PDF