• Title/Summary/Keyword: simultaneous resonance

Search Result 84, Processing Time 0.017 seconds

Testing for Measurement Invariance of Fashion Brand Equity (패션브랜드 자산 측정모델의 등치테스트에 관한 연구)

  • Kim Haejung;Lim Sook Ja;Crutsinger Christy;Knight Dee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1583-1595
    • /
    • 2004
  • Simon and Sullivan(l993) estimated that clothing and textile related brand equity had the highest magnitude comparing any other industry category. It reflects that fashion brands reinforce the symbolic, social values and emotional characteristics being different from generic brands. Recently, Kim and Lim(2002) developed a fashion brand equity scale to measure a brand's psychometric properties. However, they suggested that additional psychometric tests were needed to compare the relative magnitude of each brand's equity. The purpose of this study was to recognize the psychometric constructs of fashion brand equity and validate Kim and Lim's fashion brand equity scale using the measurement invariance test of cross-group comparison. First, we identified the constructs of fashion brand equity using confirmatory factor analysis through structural equation modeling. Second, we compared the relative magnitude of two brands' equity using the measurement invariance test of multi-group simultaneous factor analysis. Data were collected at six major universities in Seoul, Korea. There were 696 usable surveys for data analysis. The results showed that fashion brand equity was comprised of 16 items representing six dimensions: customer-brand resonance, customer feeling, customer judgment, brand imagery, brand performance and brand awareness. Also, we could support the measurement invariance of two brands' equities by configural and metric invariance tests. There were significant differences in five constructs' mean values. The greatest difference was in customer feeling; the smallest, in customer judgment.

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.