• 제목/요약/키워드: simultaneous resolution

검색결과 153건 처리시간 0.032초

Simultaneous Estimation of Spatial Frequency and Phase Based on an Improved Component Cross-Correlation Algorithm for Structured Illumination Microscopy

  • Zhang, Yinxin;Deng, Jiajun;Liu, Guoxuan;Fei, Jianyang;Yang, Huaidong
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.317-325
    • /
    • 2020
  • Accurate estimation of spatial frequencies and phases for illumination patterns are essential to reconstructing super-resolution images in structured illumination microscopy (SIM). In this manuscript, we propose the improved component cross-correlation (ICC) algorithm, which is based on optimization of the cross-correlation values of the overlapping information between various spectral components. Compared to other algorithms for spatial-frequency and phase determination, the results calculated by the ICC algorithm are more accurate when the modulation depths of the illumination patterns are low. Moreover, the ICC algorithm is able to calculate the spatial frequencies and phases simultaneously. Simulation results indicate that even if the modulation depth is lower than 0.1, the ICC algorithm still estimates the parameters precisely; the images reconstructed by the ICC algorithm are much clearer than those reconstructed by other algorithms. In experiments, our home-built SIM system was used to image bovine pulmonary artery endothelial (BPAE) cells. Drawing support from the ICC algorithm, super-resolution images were reconstructed without artifacts.

Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

  • Suraj Adhikari;Alisha Bhandari;Wonjae Lee
    • 분석과학
    • /
    • 제36권4호
    • /
    • pp.143-151
    • /
    • 2023
  • Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.

Simultaneous detection of fungal, bacterial, and viral pathogens in insects by multiplex PCR and capillary electrophoresis

  • Kwak, Kyu-Won;Nam, Sung-Hee;Choi, Ji-Young;Lee, Seokhyun;Kim, Hong Geun;Kim, Sung-Hyun;Park, Kwan-Ho;Han, Myung-Sae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제30권2호
    • /
    • pp.64-74
    • /
    • 2015
  • Beetles Protaetia brevitarsis seulensis Kolbe (Coleoptera: Cetoniidae) and Allomyrina dichotoma Linn. (Coleoptera: Scarabaeidae) are widely used in traditional medicine, and the number of insect-rearing farms is increasing in South Korea. The purpose of this study was to establish a multiplex PCR-based assay for rapid simultaneous detection of multiple pathogens causing insect diseases. Six insect parasites such as fungi Beauveria bassiana (Bals.-Criv.) Vuill. (Hypocreales: Cordycipitaceae) and Metarhizium anisopliae (Metschn.) Sorokin (Hypocreales: Clavicipitaceae), bacteria Bacillus thuringiensis Berliner (Bacillales: Bacillaceae), Pseudomonas aeruginosa Migula (Pseudomonadales: Pseudomonadaceae), and Serratia marcescens Bizio (Enterobacteriales: Enterobacteriaceae), and Oryctes rhinoceros nudivirus were chosen based on the severity and incidence rate of insect diseases in South Korea. Pathogen-specific primers were designed and successfully applied for simultaneous detection of multiple infectious agents in farm-bred insects P. b. seulensis and A. dichotoma using multiplex PCR and high resolution capillary electrophoresis. Our results indicate that multiplex PCR is an effective and time-saving method for simultaneous detection of multiple infections in insects, and the QIAxcel capillary electrophoresis system is useful for quantitative evaluation of the individual impact of each infectious agent on the severity of insect disease. The approach designed in this study can be utilized for rapid and accurate diagnostics of infection in insect farms.

중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구 (Development of a Portable Detection System for Simultaneous Measurements of Neutrons and Gamma Rays)

  • 김희경;홍용호;정영석;김재현;박수연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.481-487
    • /
    • 2020
  • Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

Sasa borealis의 Diastereomeric 성분들의 역상 고속액체크로마토그래프 분석방법 (Reverse-Phase HPLC Method for Identification of Diastereomeric Constituents from Sasa borealis)

  • 정연희;이준;권영주;서은경
    • 약학회지
    • /
    • 제50권1호
    • /
    • pp.21-25
    • /
    • 2006
  • Reiterated normal-phase column chromatography lead to the isolation and purification of six known compounds but for the first time from the whole plant of Sasa borealis (Hack.) Makino (Gramineae): tricin 4'-O-(erythro-${\beta}$-guaia-cylglyceryl) ether (1), tricin 4'-O-(threo-${\beta}$-guaiacylglyceryl) ether (2), tricin 4'-O-[erythro-${\beta}$-guaiacyl-(9'-O-acetyl)-glyceryl] ether (3), tricin 4'-O-[threo-${\beta}$-guaiacyl-(9'-O-acetyl)-glyceryl] ether (4), (-)-pinoresinol (5), and vanillin (6). The structures of the compounds (1-6) were established based on interpretation of high resolution NMR (COSY, HSQC, HMBC, and NOESY) spectral data. In particular, compounds 1 and 3 were diastereomers of compounds 2 and 4, respectively. These two sets of diastereomers were able to be simultaneously identified and quantified by a gradient reversed-phase HPLC method with UV photodiode array, This sensitive HPLC method is noteworthy as a simultaneous separation and identification method to test the extract of the family Gramineae which contains these compounds.

동시 다중 주사 방식의 초음파 합성구경 빔포머 구조 (Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach)

  • 이유화;김승수;안영복;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.803-810
    • /
    • 2007
  • Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.

단일 광섬유 격자와 Erbium과 Ytterbium 첨가된 광섬유를 이용한 스트레인 및 온도의 동시 측정 (Simultaneous Measurement of Strain and Temperature by use of Fiber Bragg Grating Written in an Erbium: Ytterbium-Doped Fiber)

  • 정재훈
    • 전기전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.117-120
    • /
    • 2004
  • 단일 광섬유 격자와 Yb와 Er이 첨가된 광섬유를 이용한 스트레인 및 온도의 동시 측정을 시행하였다. 스트레인과 온도에 대해서 $1100\;{\mu}{\varepsilon}$ and $50-180\;^{\circ}C$ 범위에서 $55.8\;{\mu}{\varepsilon}$$3\;^{\circ}C$의 오차를 가지고 측정하였다. 본 센서의 소형 및 저가의 특성으로 미루어 볼 때 넓은 범위의 스트레인 센서로 활용가치가 높다고 사료된다.

  • PDF

기체크로마토그래피를 이용한 잔류농약 동시다성분 분석법 (Determination of Simultaneous Analytical Method of Residual Pesticides by Gas Chromatography)

  • 최원조;최계선;이희정;원영준;박흥재;김우성
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1369-1381
    • /
    • 2009
  • The simultaneous determination of residual pesticides was developed using a gas chromatography. In this study, a simple and reliable methodology was improved to detect 175 kinds of residual pesticides by a liquid-liquid extraction procedure, followed by chromatographic analysis by gas chromatography. The 175 kinds of residual pesticides was classified into 4 groups according to the chemical structure, column type, resolution and sensitivity. The soybean sample selected for recovery experiment was not detected any pesticides. The recovery rates were ranged from 70.6% to 119.7% in most pesticides. The relative standard deviation (RSD 0.3~5.6%) was lower than 5.6% in all cases. The limits of detection (LOD) was lower than the maximum residue levels established by Korean legislations. The method has been successfully applied to the analysis of approximately 130 real samples.

Large-scale Synthesis of Uniform-sized Nanoparticles for Multifunctional Medical Applications

  • Hyeon, Taeg-Hwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.1-1
    • /
    • 2011
  • We developed a new generalized synthetic procedure, called as "heat-up process," to produce uniform-sized nanocrystals of many transition metals and oxides without a size selection process. We were able to synthesize uniform magnetite nanocrystals as much as 1 kilogram-scale from the thermolysis of Fe-oleate complex. Clever combination of different nanoscale materials will lead to the development of multifunctional nano-biomedical platforms for simultaneous targeted delivery, fast diagnosis, and efficient therapy. In this presentation, I would like to present some of our group's recent results on the designed fabrication of multifunctional nanostructured materials based on uniform-sized magnetite nanoparticles and their medical applications. Uniform ultrasmall iron oxide nanoparticles of <3 nm were synthesized by thermal decomposition of iron-oleate complex in the presence of oleyl alcohol. These ultrasmall iron oxide nanoparticles exhibited good T1 contrast effect. In in vivo T1 weighted blood pool magnetic resonance imaging (MRI), iron oxide nanoparticles showed longer circulation time than commercial gadolinium complex, enabling high resolution imaging. We used 80 nm-sized ferrimagnetic iron oxide nanocrystals for T2 MRI contrast agent for tracking transplanted pancreatic islet cells and single-cell MR imaging. We reported on the fabrication of monodisperse magnetite nanoparticles immobilized with uniform pore-sized mesoporous silica spheres for simultaneous MRI, fluorescence imaging, and drug delivery. We synthesized hollow magnetite nanocapsules and used them for both the MRI contrast agent and magnetic guided drug delivery vehicle.

  • PDF

가중된 직교 선형 FM신호를 이용한 송신 동시 다중 빔집속 기반의 초음파 영상 기법 (Simultaneous Multiple Transmit Focusing Using Orthogonal Weighted Linear FM Chirp)

  • 정영관;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.155-158
    • /
    • 2001
  • A new method for simultaneous multiple transmit focusing using orthogonal weighted FM chirp is proposed. Weighted chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in the approximate sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels, and the crosscorrellation function of any pair of the signals has smaller values than the sidelobe levels of each autocorrelation function. This means that each weighted chirp signal can be separately compressed into a short pulse, focused individually and combined with other focused beams to form a frame of image. Theoretically, any two chirp signals defined in two nonoverlapped frequency bands are mutually orthogonal. In the present work, however, a fractional overlap of adjacent frequency bands, by up to 25%, were permitted to design more chirp signals within a given transducer bandwidth. The crosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals. The simulation results show that this method can improve the lateral resolution of image without sacrifice in the frame rate compared with the conventional pulse system.

  • PDF