• Title/Summary/Keyword: simultaneous resolution

Search Result 154, Processing Time 0.034 seconds

Study on Three-dimension Reconstruction to Low Resolution Image of Crops (작물의 저해상도 이미지에 대한 3차원 복원에 관한 연구)

  • Oh, Jang-Seok;Hong, Hyung-Gil;Yun, Hae-Yong;Cho, Yong-Jun;Woo, Seong-Yong;Song, Su-Hwan;Seo, Kap-Ho;Kim, Dae-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.98-103
    • /
    • 2019
  • A more accurate method of feature point extraction and matching for three-dimensional reconstruction using low-resolution images of crops is proposed herein. This method is important in basic computer vision. In addition to three-dimensional reconstruction from exact matching, map-making and camera location information such as simultaneous localization and mapping can be calculated. The results of this study suggest applicable methods for low-resolution images that produce accurate results. This is expected to contribute to a system that measures crop growth condition.

MEASURING THE CORE SHIFT EFFECT IN AGN JETS WITH THE EXTENDED KOREAN VLBI NETWORK

  • JUNG, TAEHYUN;DODSON, RICHARD;HAN, SEOG-TAE;RIOJA, MARIA J.;BYUN, DO-YOUNG;HONMA, MAREKI;STEVENS, JAMIE;VICENTE, PABLO DE;SOHN, BONG WON
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.277-284
    • /
    • 2015
  • We present our efforts for extending the simultaneous multi-frequency receiver system of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN) to global baselines in order to measure the frequency-dependent position shifts in Active Galactic Nuclei (AGN) jets, the so called core shift effect, with an unprecedented accuracy (a few micro-arcseconds). Millimeter VLBI observations with simultaneous multi-frequency receiver systems, like those of the KVN, enable us to explore the innermost regions of AGN and high precision astrometry. Such a system is capable of locating the frequency dependent opacity changes accurately. We have conducted the feasibility test-observations with the interested partners by implementing the KVN-compatible systems. Here we describe the science case for measuring the core shift effect in the AGN jet and report progress and future plans on extending the simultaneous multi-frequency system to global baselines.

An Incremental Statistical Method for Daily Activity Pattern Extraction and User Intention Inference

  • Choi, Eu-Ri;Nam, Yun-Young;Kim, Bo-Ra;Cho, We-Duke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.3
    • /
    • pp.219-234
    • /
    • 2009
  • This paper presents a novel approach for extracting simultaneously human daily activity patterns and discovering the temporal relations of these activity patterns. It is necessary to resolve the services conflict and to satisfy a user who wants to use multiple services. To extract the simultaneous activity patterns, context has been collected from physical sensors and electronic devices. In addition, a context model is organized by the proposed incremental statistical method to determine conflicts and to infer user intentions through analyzing the daily human activity patterns. The context model is represented by the sets of the simultaneous activity patterns and the temporal relations between the sets. To evaluate the method, experiments are carried out on a test-bed called the Ubiquitous Smart Space. Furthermore, the user-intention simulator based on the simultaneous activity patterns and the temporal relations from the results of the inferred intention is demonstrated.

Simultaneous Analytical Method of Organochlorine and Pyrethroid Pesticides using GC(ECD) (GC-ECD를 이용한 유기염소계 밑 Pyrethroid계 농약 동시 분석법)

  • 김우성;이선화;김재이;정지윤;이명자;박영채;이영자;정성욱;이봉헌
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.477-480
    • /
    • 2003
  • Pesticides were extracted from samples with 70% acetone and methylene chloride in order, and then cleaned up via open-column chromatography apparatus packed with florisil, and finally analyzed simultaneously the organochlorine and pyrethroid pesticides using GC(ECD). An ultra-2 fused silica capillary column was used to separate and identify the products. The resolution between the last isomeric peak of cypermethrin(59.987min) and the first isomeric peak of flucythrinate(60.043min) was not satisfactory. The last isomeric peak of fenvalerate(62.344min) and the first isomeric peak of fluvalinate(62.397min) were overlapped. Recoveries of soybean sample fer the most pesticides were 73.3% to 102.4%. Detection limits were between 0.004 and 0.063 ${\mu}$g/mg when this method was used.

Simultaneous Measurement of Strain and High Frequency Vibration of Composite Main Wing Model (복합재 주 날개 모델의 변형률과 진동의 동시 측정)

  • Song, Ji-Yong;Yoon, Hyuk-Jin;Park, Sang-Wuk;Park, Sang-Oh;Kim, Chon-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.185-189
    • /
    • 2005
  • For the simultaneous measurement of strain and vibration signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter could measure low-frequency signal such as strain and the other demodulator using a coarse wavelength division multiplexer could detect high-frequency signal such as vibration signal using intensity demodulation method. In order to measure strain and vibration of the composite main wing model under static loading a real time monitoring program was developed. Also using intensity demodulation of CWDM, sensitivity and resolution at high frequency vibration were evaluated.

  • PDF

SUBMICRON-RESOLUTION DOMAIN REVERSAL STUDY OF Co-BASED MULTILAYERS USING MAGNETO-OPTICAL MICROSCOPE MAGNETOMETER (MOMM)

  • Shin, Sung-Chul;Choe, Sug-Bong
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.121-146
    • /
    • 2000
  • A novel system of magneto-optical microscope magnetometer (MOMM), capable of simultaneous local problems of magnetic properties as well as real-time magnetic domain evolution imaging of ferromagnetic thin films with 400-nm spatial resolution, New findings in domain reveral dynamics of Co-based multilayers: The reversal ratio of V/R is a governing physical parameter. The activation volumes of wall-motion and nucleation processes are generally unequal. Submicron-scale local coercivity variation determines domain reversal dynamics. A thermally activated relaxation process during domain reversal is existed on the submicron-scale in realistic films. Local variation of magnetic properties should be considered for a realistic simulation. The fantastic capabilities of the MOMM can open many possibilities to broaden and deepen our understanding of domain reversal phenomena in ferromagnetic thin films.

  • PDF

Simultaneous Analysis of Cold Medicine Component by High-Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 Cold Medicine 성분의 동시 분석)

  • Wonju Lee;Seung-Tae Choi;Keun-Sik Shin;Jin-Young Park;Jae-Ho Sim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.867-873
    • /
    • 2023
  • In this study, for the purpose of standardized quality control of a cold medicine, we simultaneous analyzed four main chemical components of a cold medicine: acetaminophen, caffeine, methyl paraben, and propyl paraben. The sample was subjected to quantitative analysis using high performance liquid chromatography (HPLC), after pretreatment of four components. The experiment was carried out by using Isocratic elution at wavelength of 270nm. Acetonitrile and water (H2O) were used as a mobile phase at a flow rate of 1.0mL/min in a commercial C18 reversed-phase column. A volume of 10uL cold medicine were injected into the column with column oven temperature at 35℃. As a result of the experiment, the values of Resolution were 4.983, 1.596, 5.519, and 1.678 respectively-well over Rs >1.5, which indicates that the separation of four components were efficient. In addition, value of symmetry factor of the components was 1.056, 1.069, 1.032, and 1.133 respectively, to show its symmetrical stability. The calibration curve of all four components exhibits good linearity with R2 >0.9995 to 0.9999. Furthermore, the limit of detection(LOD) were between 0.0118 to 1.5973 mg/mL, while the limit of quantification (LOQ) were between 0.0353 to 4.7919 ㎍/mL with the recovery rate of 79.6% ~ 120.5%. The results of this study showed an efficient quality evaluation of a simultaneous analysis method for cold medicine components.

Multi-Detector Row CT of the Central Airway Disease (Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가)

  • Kang, Eun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

Helicopter-borne electromagnetic surveys for civil engineering in Japan

  • Konishi Naotoshi;Ashida Yuzuru
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.422-431
    • /
    • 2003
  • Helicopter-borne electromagnetic (HEM) systems were originally developed for the exploration of mineral deposits. The frequency range of a conventional HEM system for mineral exploration, however, is relatively low and so not invariably suitable for its application to the fields of civil engineering because of its poor resolution in the shallower part of the earth. A DIGHEM HEM system was acquired by Nippon Engineering, with the frequencies chosen by the senior author. The five frequencies range from 220 Hz (the lowest) to 137,500 Hz (the highest). These frequencies improve the resolution of materials in the shallower part while maintaining a depth of investigation of greater than 100 m. This paper describes six case histories of geological and geotechnical surveys for civil engineering using HEM. These case histories include HEM surveys for investigating landslide, an alluvial area, root selection of road construction, areas related to dam and tunnel construction, and the simultaneous joint inversion of HEM and CSAMT data for a deep tunnel. These survey results show that HEM has sufficient resolution in both horizontal and vertical directins to contribute significantly to outlining the regional geology and its engineering problems.

  • PDF

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • Heo, Seung-Jin;Kim, Gi-Beom;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF