• 제목/요약/키워드: simulated result

검색결과 2,332건 처리시간 0.03초

Simulated Dynamic C&C Server Based Activated Evidence Aggregation of Evasive Server-Side Polymorphic Mobile Malware on Android

  • Lee, Han Seong;Lee, Hyung-Woo
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 2017
  • Diverse types of malicious code such as evasive Server-side Polymorphic are developed and distributed in third party open markets. The suspicious new type of polymorphic malware has the ability to actively change and morph its internal data dynamically. As a result, it is very hard to detect this type of suspicious transaction as an evidence of Server-side polymorphic mobile malware because its C&C server was shut downed or an IP address of remote controlling C&C server was changed irregularly. Therefore, we implemented Simulated C&C Server to aggregate activated events perfectly from various Server-side polymorphic mobile malware. Using proposed Simulated C&C Server, we can proof completely and classify veiled server-side polymorphic malicious code more clearly.

최소자승법에 의한 ABS(Antilock Braking System)의 모델링 및 파라미터 평가 (Modeling and Parameter estimation of Antilock Braking System)

  • 송창섭;노형우
    • 한국정밀공학회지
    • /
    • 제19권4호
    • /
    • pp.87-92
    • /
    • 2002
  • By using the signal error test, model structure of total antilock braking system consisting of electromagnetic system and hydraulic system is determined as 9th order system. For determining parameters of the ABS, using time discrete model of parametric method, parameters in time discrete model are searched by least square method. By bilinear transform, we have found the model of ABS in s domain. Afterward, experimental output data is compared with simulated output data by MATLAB haying identified parameter. As the result, experimental data is agreed with simulated data very well.

최소자승법에 의한 A/T용 솔레노이드 밸브의 모델링 및 파라미터 평가 (Modeling and Parameter Estimation of Solenoid Valve in Automatic Transmission by the Least Square Method)

  • 노형우;박상훈;송창섭
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.98-104
    • /
    • 2003
  • Model structure of solenoid valve in the automatic transmission is determined as 5th order system by the signal error test. For determining parameter of the solenoid valve, parameters in time discrete model are searched by the least square method. By bilinear transform, we have found the model of solenoid valve in s domain. Afterward, experimental output data is compared with simulated output data by MATLAB having identified parameter. As the result, experimental data is agreed with simulated data very well.

공정변수에 따른 레이저표면합금층의 형상 및 성분변화에 관한 연구 (Shape and Chemical Composition of Laser Surface Alloyed Layer under Moving Laser Source)

  • 최정영;이창희
    • 한국레이저가공학회지
    • /
    • 제2권2호
    • /
    • pp.8-17
    • /
    • 1999
  • This study includes a basic feature of laser surface alloying for enhancing the surface properties of materials. Effects of laser processing parameters such as beam power, beam size, scanning speed on the shape and composition of alloyed layer was simulated in case of moving beam conditions (2-dimensional numerical methods). Simulated results were compared with experiments, in which the plasma coating of 80% Ni + 20% Cr deposited on the SS41 substrate was remelted with CO2 laser with Gaussian energy distribution. Simulation and experiments revealed that the shape (dimension)and composition of laser alloyed layer were strongly dependent upon the process parameters, especially interaction time (travel speed) as compared to beam diameter, beam power and absorptivity. The shape and composition of alloyed layervaried more or less exponentially with parameters.

  • PDF

매입형 영구자석 동기전동기의 최적설계를 위한 시뮬레이티드 애닐링과 결정론적 탐색법의 혼합적용 (An Application of Simulated Annealing Combining Deterministic Search to Optimal Design of Interior Permanent Magnet Synchronous Motors)

  • 심동준;정현교;한송엽;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.159-161
    • /
    • 1994
  • This paper presents a combined algorithm of simulated annealing and determinstic method which overcomes the defects of two methods and guarantees the fast convergence to the global optimum. This optimization method is applied to optimal design of Interior Permanent Magnet Synchronous Motor. And the result of the proposed algorithm is compared with that of simulated annealing alone.

  • PDF

오리피스 유량해석을 통한 전륜 착륙장치의 착륙성능평가 (Nose Landing Gear Drop-test Simulation using Numerical Analysis about Orifice)

  • 황재업;배재성;황재혁;홍예선;박상준;정태경
    • 항공우주시스템공학회지
    • /
    • 제8권1호
    • /
    • pp.18-23
    • /
    • 2014
  • This thesis is simulated a aircraft nose landing gear drop-test. flow rate-to-pressure difference characteristics of damping orifices for a nose landing gear is investigated by CFD analyses. Orifice is kind of poppet valve type. it is simulated pressure drop with variable orifice area. it is simulated landing gear model by using ADAMS with CFD result. It's performance evaluated landing gear drop-test and analyzed the results.

Leakage Flux Distribution in the Simulated Environment

  • Kim, Chung-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.401-405
    • /
    • 2012
  • Current research about voltage leakage involves investigation of the effects of leaked voltage and current on humans through simulated environments and dummies. Electrocution results from leaked current when electricity flows through the body as a result of potential difference. Research that analyzes actual electrocution is insufficient because of the danger from leaked voltage present in the leakage area. This thesis analyzes magnetic flux density from current around a leak to investigate the distribution of current. The authors used a simulated environment to investigate electrocution accidents that frequently occur during floods through leakage along metal surfaces, and evaluated the distribution of leaked magnetic flux.

Location Analysis for Emergency Medical Service Vehicle in Sub District Area

  • Nanthasamroeng, Natthapong
    • Industrial Engineering and Management Systems
    • /
    • 제11권4호
    • /
    • pp.339-345
    • /
    • 2012
  • This research aims to formulate a mathematical model and develop an algorithm for solving a location problem in emergency medical service vehicle parking. To find an optimal parking location which has the least risk score or risk priority number calculated from severity, occurrence, detection, and distance from parking location for emergency patients, data were collected from Pratoom sub-district Disaster Prevention and Mitigation Center from October 2010 to April 2011. The criteria of risk evaluation were modified from Automotive Industry Action Group's criteria. An adaptive simulated annealing algorithm with multiple cooling schedules called multi-agent simulated quenching (MASQ) is proposed for solving the problem in two schemes of algorithms including dual agent and triple agent quenching. The result showed that the solution obtained from both scheme of MASQ was better than the traditional solution. The best locations obtained from MASQ-dual agent quenching scheme was nodes #5 and #133. The risk score was reduced 61% from 6,022 to 2,371 points.

Development of the Electromagnetic Wave Absorber for 94 GHz Radar Sensors Using Permalloy

  • Choi, Chang-Mook;Kim, Dong-Il;Li, Rui;Ko, Kwang-Soob
    • Journal of information and communication convergence engineering
    • /
    • 제4권3호
    • /
    • pp.114-117
    • /
    • 2006
  • In this paper, we fabricated the EM wave absorber for 94 GHz radar sensors using Permalloy of magnetic material with chlorinated polyethylene (CPE), and S-parameter was measured. The complex relative permittivity and permeability are calculated by the measured data. Absorption abilities are simulated according to different thickness of the EM wave absorbers, and the EM wave absorber was manufactured based on the simulated design. Simulated and measured results agree very well. As a result, we developed the EM wave absorber with the thickness of 1.15 mm which has an absorption ability of 18 dB at 94 GHz.

사이버전 훈련을 위한 ATT&CK 기반 모의 위협 발생기 설계 및 구현 (The Design and Implementation of Simulated Threat Generator based on MITRE ATT&CK for Cyber Warfare Training)

  • 홍수연;김광수;김태규
    • 한국군사과학기술학회지
    • /
    • 제22권6호
    • /
    • pp.797-805
    • /
    • 2019
  • Threats targeting cyberspace are becoming more intelligent and increasing day by day. To cope with such cyber threats, it is essential to improve the coping ability of system security officers. In this paper, we propose a simulated threat generator that automatically generates cyber threats for cyber defense training. The proposed Simulated Threat Generator is designed with MITRE ATT & CK(Adversarial Tactics, Techniques and Common Knowledge) framework to easily add an evolving cyber threat and select the next threat based on the threat execution result.