• Title/Summary/Keyword: simulated records

Search Result 82, Processing Time 0.022 seconds

Smart System Identification of Super High-Rise Buildings using Limited Vibration Data during the 2011 Tohoku Earthquake

  • Ikeda, A.;Minami, Y.;Fujita, K.;Takewaki, I.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.4
    • /
    • pp.255-271
    • /
    • 2014
  • A method of smart system identification of super high-rise buildings is proposed in which super high-rise buildings are modeled by a shear-bending system. The method is aimed at finding the story shear and bending stiffnesses of a specific story only from the horizontal floor accelerations. The proposed method uses a set of closed-form expressions for the story shear and bending stiffnesses in terms of the limited floor accelerations and utilizes a reduced shear-bending system with the same number of elements as the observation points. A difficulty of prediction of an unstable specific function in a low frequency range can be overcome by introducing an ARX model and discussing its relation with the Taylor series expansion coefficients of a transfer function. It is demonstrated that the shear-bending system can simulate the vibration records with a reasonable accuracy. It is also shown that the vibration records at two super high-rise buildings during the 2011 Tohoku (Japan) earthquake can be simulated with the proposed method including a technique of inserting degrees of freedom between the vibration recording points. Finally it is discussed further that the time-varying identification of fundamental natural period and stiffnesses can be conducted by setting an appropriate duration of evaluation in the batch least-squares method.

Identification of major rice allergen and their clinical significance in children

  • Jeon, You-Hoon;Oh, Se-Jo;Yang, Hyeon-Jong;Lee, Soo-Young;Pyun, Bok-Yang
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.10
    • /
    • pp.414-421
    • /
    • 2011
  • Purpose: Recently, an increase in the number of patients sensitized to rice allergen with or without clinical symptoms has been reported. This study was designed to determine the major allergens in rice and their clinical significance. Methods: Twenty-four children (15 boys and 9 girls; mean age, 16.3 months) with allergic disease, who were sensitized to rice antigen (by UniCAP) in the Pediatric Allergy Respiratory Center at Soonchunhyang University Hospital, were enrolled in this study. The allergenicity of various types of rice (raw, cooked, and heat-treated, simulated gastric fluid [SGF], and simulated intestinal fluid [SIF]) was investigated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoglobulin E (IgE) immunoblots. The patients' medical records, including laboratory data and allergy symptoms after ingestion of rice were reviewed. Results: Patients were sensitized to an average of 13.5 food antigens and their mean total IgE was 6,888.7 kU/L. In SDS-PAGE, more than 16 protein bands were observed in the raw rice, whereas only 14-16 kDa and 31-35 kDa protein bands were observed in cooked rice. The common SDS-PAGE protein bands observed in SGF-, SIF-, and heat-treated rice were 9, 14, and 31 kDa. In a heated-rice IgE immunoblot, protein bands of 9, 14, and 31-33 kDa were found in 27.8%, 38.9%, and 38.9% of all sera, respectively, and in 50%, 50%, and 75%, of ser a from the 4 symptomatic patients, respectively. Conclusion: The 9-, 14-, and 31-kDa protein bands appeared to be the major allergens responsible for rice allergy symptoms.

Estimation of extreme sea levels at tide-dominated coastal zone (조석이 지배적인 해역의 극치해면 산정)

  • Kang, Ju Whan;Kim, Yang-Seon;Cho, Hongyeon;Shim, Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.6
    • /
    • pp.381-389
    • /
    • 2012
  • An EST-based method which is applicable for estimating extreme sea levels from short sea-level records in a tide dominated coastal zone was developed. Via the method, annual maximum tidal level is chosen from the simulated 1-yr tidal data which are constituted by the independent daily high water levels, short term and long term surge heights and typhoon-induced surge heights. The high water levels are generated considering not only spring/neap tides and annual tide but also 18.6-year lunar nodal cycle. Typhoon-induced surges are selected from the training set which is constructed by observed or simulated surge heights. This yearly simulation is repeated many hundred years to yield the extreme tidal levels, and the whole process is carried out many hundred times repeatedly to get robust statistics of the levels. In addition, validation of the method is also shown by comparing the result with other researches with the tidal data of Mokpo Harbor.

Water Quality Modeling by the WASP4 Model (WASP4 모형에 의한 수질모델링)

  • 조홍연;전경수;이길성
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.3
    • /
    • pp.221-231
    • /
    • 1993
  • WASP4. an estuarine or lake water quality model, wat applied to simulate future water qualities at alternative withdrawal sites for capital areas. Simulated water quality constituents were Chlorophyll a, nitrogen cycles, Phosphorus, BOD End DO. A Water budget analysis Using the monthly records of reservoir inflows and outflows between 1986 and 1990 was made to determine seasonally-averaged flowrates at model boundaries. Estimated flowrates were used. together with the seasonal water quality inputs simulated by the QUAL2E model, for the simulation of future water qualities. Sensitivities to the future pollutant inputs and possible future withdrawal alternatives were also analyzed. From simulations or future water qualities it is found that among the candidate withdrawal sites. the one located at the downstream end of the North Han River has the best future water quality in all quality constituents and the one at the downstream end of the South Han River has the worst Possible future withdrawal from the North Han River brings a slight increase or pollutant concentrations at existing withdrawal sites. but the aggravation of water quality is not significant.

  • PDF

Water Quality Modeling for Bokha Stream by WASP5 Model (WASP5 모형을 적용한 복하천의 수질 예측)

  • Shin, Dong-Seok;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.233-238
    • /
    • 1997
  • WASP5 was applied to evaluate water quality of Bokha stream with 17km of its main stem located in Ichon-city, Kyunggi province in Korea. Boundaries of the stream for the WASP5 were the Jumi bridge, 10 major tributaries and one wastewater treatment system. The stream was divided into 37 segments with about 350m length. The flowrate of the 10 day's average of the stream was obtained from the hydrograph data and the discharge-stage rating curve. Simulated quality constituents included nitrogen, phosphorus, BOD and DO. Monthly records of water quality and loads in 1996 were used for the calibration of parameters of WASP5. Simulation showed high correlations between calculated and observed concentration with monthly runoff ratio in Bokha stream. At downstream boundary, Jumi bridge [Seg.36], similar correlations were appeared. However, simulated concentrations by using annual runoff ratio were somewhat differentiated from those of the observed.

  • PDF

Detailed Finite Element Analysis of Full-scale Four-story Steel Frame Structure subjected to Consecutive Ground Motions

  • Tagawa, Hiroyuki;Miyamura, Tomoshi;Yamashita, Takuzo;Kohiyama, Masayuki;Ohsaki, Makoto
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 2015
  • Detailed finite element (FE) analyses of a full-scale four-story steel frame structure, subjected to consecutive 60% and 100% excitations from the JR Takatori records during the 1995 Hyogoken-Nanbu earthquake, are conducted using E-Simulator. The four-story frame was tested at the largest shake-table facility in the world, E-Defense, in 2007. E-Simulator is a parallel FE analysis software package developed to accurately simulate structural behavior up to collapse by using a fine mesh of solid elements. To reduce computational time in consecutive dynamic time history analyses, static analysis with gravity force is introduced to terminate the vibration of the structure during the analysis of 60% excitation. An overall sway mechanism when subjected to 60% excitation and a story mechanism resulting from local buckling of the first-story columns when subjected to 100% excitation are simulated by using E-Simulator. The story drift response to the consecutive 60% and 100% excitations is slightly smaller than that for the single 100% excitation.

Failure distribution based crack propagation in solid propellant container: Comparison with experiment (고체추진기기의 고장분포 기반의 균열전파 모델: 실험과의 비교)

  • Yoh Jai-ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.47-52
    • /
    • 2005
  • We present a simple idea to simulate dynamic fracture and fragmentation of a propulsion system exposed to an extreme condition, such as a fire. The system consists of energetic materials confined in a steel cylinder. The strain failure model of the confinement is a modified Johnson-Cook model with a statistical failure distribution. By using the size distribution data of the fragments from the thermal explosion tests, the failure strain distribution can be empirically obtained and then entered into the model. The simulated fracture and fragment sizes are compared with the experimental records.

  • PDF

Analysis of Surplus and Dficit-using Runs for Monthly Streamflow (월유출량에 대한 Run-Length의 해석)

  • Gang, Gwan-Won;An, Gyeong-Su;Kim, Yang-Su
    • Water for future
    • /
    • v.18 no.4
    • /
    • pp.317-325
    • /
    • 1985
  • In the analysis, monthly streamflow records atthe gauging station in Nakdong, Han and Geum river were used. Also, the fitness of monthly streamflow to Gamma and Long-normal distribution was tested by Kolomogorv-Smirnov test. The results obtained in this study can be summarized as follws (1) The fitness of monthly streamflow to two-parameter Gamma distribution was tested by Kolomorov-Smirnov test, which fits well to this Gamma distribution (2) The Run-length and Run-sum were simulated by the Gamma model. In this result, run-length and Run-sum of monthly streamflow were fit for Gamma model (3) The mean decreases (increases) the expected surplus (deficit) Run-Sum of the monthly streamflow. The higher the truncation level of negative Run-length and Run-sum the larger is the effect of mean.

  • PDF

Dam Failure and Unsteady Flow Analysis through Yeoncheon Dam Case(II) - Unsteady Flow Analysis of Downstream by Failure Scenarios - (연천댐 사례를 통한 댐 파괴 부정류해석 및 하류 영향 검토(II) -시나리오에 따른 댐 하류 부정류 해석 및 범랑특성 연구-)

  • Jang, Suk-Hwan
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1295-1305
    • /
    • 2008
  • This study aims at the analyze of unsteady downstream flow due to dam failure along dam failure scenario and applied to Yeoncheon Dam which was collapsed August 1st 1999, using HEC-RAS simulation model. The boundary conditions of this unsteady flow simulation are that dam failure arrival time could be at 02:45 a.m. August 1st 1999 and failure duration time could be also 30 minutes. Downstream 19.5 km from dam site was simulated for unsteady flow analysis in terms of dam failure and non-failure cases. For the parameter calibration, observed data of Jeonkok station were used and roughness coefficient was applied to simulation model. The result of the peak discharge difference was 2,696 to $1,745\;m^3/sec$ along the downstream between dam failure and non-failure and also peak elevation of water level showed meanly 0.6m difference. Those results of these studies show that dam failure scenarios for the unknown failure time and duration were rational because most results were coincident with observed records. And also those results and procedure could suggest how and when dam failure occurs and downstream unsteady flow analyzes.

The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital (대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.