• Title/Summary/Keyword: simulated canal

Search Result 92, Processing Time 0.027 seconds

THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL (제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과)

  • Choi, Hee-Won;Kim, Soo-Mee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal. 50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block. The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip. All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (${\times}2.3$). The results are as follows : 1. In control group, there was no gutta-percha and sealer in lingual canal. 2. 3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05). 3. 7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05) In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study (Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구)

  • Kim, Hyeon-Cheol;Kwak, Sang Won;Ha, Jung-Hong
    • The Journal of the Korean dental association
    • /
    • v.55 no.10
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

The ability of using syringe irrigation and ultrasound irrigation to remove dentin debris from simulated extensions and irregularities in root canals

  • Lee, Se-Joon;Wu, Min-Kai;Wesselink, Paul-R.
    • Proceedings of the KACD Conference
    • /
    • 2003.05a
    • /
    • pp.289-289
    • /
    • 2003
  • I. Objectives Narrow long oval canals usually cannot be instrumented completely and uninstrumented extensions or irregularities usually remain. The aim of this study was to compare the ability of syringe irrigation and ultrasound irrigation to remove dentin debris from simulations of uninstrumented canal extensions and irregularities.(omitted)

  • PDF

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.

EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS (모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향)

  • Nam, Deuk-Lim;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n=15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of micro leakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p<0.05).

Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

  • Jang, Ju-Kyong;Kwak, Sangwon;Choi, Ga Young;Ha, Jung-Hong;Choi, Sung-Baik;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.53 no.10
    • /
    • pp.743-750
    • /
    • 2015
  • Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS (엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향)

  • Roh, Hyoung-Mee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.486-492
    • /
    • 2005
  • The purpose of this study was to compare the shaping ability of the two different Ni-Ti file systems and the two different engine systems in simulated canals. A total of four groups of each 10 were tested. Each group was instrumented with HeroShaper and Endo-Mate2 (Croup HE), HeroShaper and Tecnika (Croup HT), ProFile and Endo-Mate2 (Group PE), and ProFile and Tecnika (Croup PT). Canal preparation time was recorded. The images of pre- and post- instrumented root canals were scanned and superimposed. The amounts of increased width and centering ratio were measured and calculated at apical 1, 3 and 5mm levels. These data were statistically analyzed with one-way ANOVA and Duncan's multiple range test The results of this study were as fellows ; 1. Canal preparation time of HT group was the shortest (p<0.05). 2. The amount of increased canal width in HE group was significantly larger than PT group at apical 1mm level (p<0.05) At apical 3mm level, PT group was significantly smaller than other groups (p<0.05). At apical 5mm level, PE group was significantly larger than PT group (p<0.05). 3. The amount of centering ratio in HE group was significantly larger than other groups (p<0.05). At apical 5mm level, HT group was significantly larger than PE group and PT group (p<0.05). Under the condition of this study, torque-controlled endodontic motor is safer than no torque controlled motor, especially when the active file is used.