• 제목/요약/키워드: simplified strength assessment

검색결과 30건 처리시간 0.02초

유조선의 간이 충돌/좌초강도 평가시스템 개발 (Development of Simplified Collision and Grounding Strength Assessment System of Oil Tankers)

  • 이탁기;김재동;전태병
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제2권2호
    • /
    • pp.86-94
    • /
    • 1999
  • This paper describes a development of Collision/grounding Strength Assessment System (COSAS) using simplified method. This method is formulated in closed-form equation by taking into account crushing caused by bulbous bow collision and cutting caused by forward speed grounding. To verify the accuracy of the developed system, some examples for test models of double side/bottom structure in collision/grounding situation are considered. This system might be useful for analysis of structural damage of oil tankers in collision/grounding.

  • PDF

Simplified methods for seismic assessment of existing buildings

  • Tehranizadeh, Mohsen;Amirmojahedi, Maryam;Moshref, Amir
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1405-1428
    • /
    • 2016
  • Besides the complex instructions of guidance documents for seismic rehabilitation of existing buildings, some institutions have provided simple criteria in terms of simplified rehabilitations. ASCE 41-06 is one of documents that introduced a simple method for assessment of certain buildings that do not require advanced analytical procedures. Furthermore the New Zealand guideline has presented a simple lateral mechanism analysis that is a hand static analysis for determining the probable collapse mechanism, lateral strength and displacement capacity of the structure. The present study is focused on verifying the results of the simplified methods which is used by NZSEE and ASCE 41-06 in assessment of existing buildings. For this, three different special steel moment and braced frames are assessed under these two guidelines and the accuracy of the results is checked with the results of nonlinear static and dynamic analysis. After comparison of obtained results, suggestions are presented to improve seismic retrofit criteria.

Arias Intensity 액상화 평가기법의 적용성에 관한 연구 (A Study on the Applicability of Arias Intensity Liquefaction Assessment)

  • 황정태;이종근;신은철
    • 한국지반환경공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.13-19
    • /
    • 2013
  • 본 연구에서는 액상화 평가 대상지반을 선정하여 미국, 일본 등 액상화 발생지역에 적용한 사례가 있는 에너지를 기반으로 하는 Arias intensity 액상화 평가법을 적용하고, 적용성을 검토하기 위하여 기존의 원위치시험을 통한 액상화 간편예측법을 수행하여 평가결과를 비교하였다. 대상지반에 대한 액상화 평가결과, Hachinohe 지진과 Ofunato 지진의 실지진기록을 이용한 Arias Intensity 안전율은 간편예측 안전율과 유사하게 산정되었으며, 설계응답스펙트럼으로부터 작성된 인공지진의 경우 Arias Intensity 안전율은 간편예측 안전율과 비교하여 다소 차이가 나타났다. 액상화를 발생시키는 전단응력비와 발생강도는 응력과 에너지라는 서로 다른 개념으로 산정되지만, 간편예측법의 전단저항응력비와 Arias Intensity의 저항강도는 실지진에 따른 액상화 발생지역을 대상으로 한 표준관입시험 등 경험적 도표를 사용한다는 점에서 Hachinohe 지진과 Ofunato 지진의 경우 Arias Intensity 평가법과 응력개념의 간편예측법 사이에 비슷한 결과가 나타난 것으로 판단된다. 따라서, 에너지를 기반으로 하는 Arias Intensity 액상화 평가법은 응력개념의 간편예측법에서 고려하지 않은 실지진 기록에 대한 가속도, 지속시간, 진폭 등의 지진특성으로 야기되는 지반의 동적변화를 표현할 수 있음을 확인할 수 있었다.

단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구 (Structural Strength Assessment of Simplified Mark III CS Plate)

  • 정한구;양영순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

Seismic demand estimation of RC frame buildings based on simplified and nonlinear dynamic analyses

  • Borzi, B.;Vona, M.;Masi, A.;Pinho, R.;Pola, D.
    • Earthquakes and Structures
    • /
    • 제4권2호
    • /
    • pp.157-179
    • /
    • 2013
  • Vulnerability studies on the existing building stock require that a large number of buildings is analyzed to obtain statistically significant evaluations of the seismic performance. Therefore, analytical evaluation methods need to be based on simplified methodologies of analysis which can afford the treatment of a large building population with a reasonable computational effort. Simplified Pushover-Based Earthquake Loss Assessment approach (SP-BELA), where a simplified methodology to identify the structural capacity of the building through the definition of a pushover curve is adopted, was developed on these bases. Main objective of the research work presented in this paper is to validate the simplified methodology implemented in SP-BELA against the results of more sophisticated nonlinear dynamic analyses (NLDAs). The comparison is performed for RC buildings designed only to vertical loads, representative of the "as built" in Italy and in Mediterranean countries with a building stock very similar to the Italian one. In NLDAs the non linear and degrading behaviour, typical of the structures under consideration when subjected to high seismic loads, is evaluated using models able to capture, with adequate accuracy, the non linear behaviour of RC structural elements taking into account stiffness degradation, strength deterioration, and pinching effect. Results show when simplified analyses are in good agreement with NLDAs. As a consequence, unsatisfactory results from simplified analysis are pointed out to address their current applicability limits.

굽힘 하중하의 고장력강 용접 연결부의 피로 평가 (Fatigue Assessment of High Strength Steel Welded Joints Under Bending Loading)

  • 이명우;김윤재;박준협
    • 대한기계학회논문집A
    • /
    • 제38권10호
    • /
    • pp.1163-1169
    • /
    • 2014
  • 본 연구에서는 자동차 서스펜션 구조에 일반적으로 사용되는 용접부 형상에 대하여 굽힘 하중에 의한 피로수명을 예측할 수 있는 절차를 개발하였다. 이종 재료로 이루어진 실제 제품 용접 연결부의 피로수명 예측을 위해, 복잡한 형상의 제품을 단순화한 용접 시편을 설계하고 이에 대한 굽힘 피로 시험을 진행한 후 모멘트-피로수명(M-N) 선도를 제시하였다. 응력 집중에 의한 영향을 분석하기 위해 시편의 형상을 모델링 한 후 정적 하중에 대한 유한요소해석을 수행하여 균열 발생부의 응력을 구하고 응력-피로수명(S-N) 선도를 제시하였다. 유한요소해석을 통해 구한 응력과 이론 계산을 통해 구해준 응력을 이용하여 응력집중계수를 계산하였고, 응력집중부의 피로평가 방법 개선을 위해 보편적으로 사용되는 피로노치계수 평가법과 굽힘 피로 시험 결과를 비교 검토하였다. 그 결과, 이종 재질 용접 연결부의 정확한 피로 수명평가를 위해서는 기하형상을 고려한 피로노치계수 평가 분석뿐만 아니라 두 소재의 맞대기 용접 시편에 대한 피로 시험을 수행해 주어야 할 것으로 판단된다.

선체 선각구조의 최종 종강도 평가에 관한 연구 (On the Ultimate Longitudinal Strength Assessment of Ships' Hull Structure)

  • 이훈곤;이주성
    • 대한조선학회논문집
    • /
    • 제43권3호
    • /
    • pp.340-350
    • /
    • 2006
  • This paper is concerned with a practical guide for the ultimate longitudinal strength assessments of ships' hull structure. Rigorous non-linear structural analysis for three tanker models has been carried out to examine the ultimate strength behavior. Formula of estimating the ultimate longitudinal strength has been proposed which is modified with the results of non-linear finite element analysis of hull girders. Computational reliability and accuracy of the large-scale non-linear finite element analysis and the proposed simplified formula are verified through comparing their results with that of 1/3 scale frigate model test and DNVs program. Additionally, the ultimate longitudinal strength for ten tanker models is compared with those by the method specified in the 2nd Draft of common structural rule for tankers, which is being developed by IACS.

Ultimate Longitudinal Strength Assessment of Ships' Hull Girders

  • Lee, Hun-Gon;Lee, Joo-Sung
    • Journal of Ship and Ocean Technology
    • /
    • 제12권1호
    • /
    • pp.45-56
    • /
    • 2008
  • Recently, International Association Classification Societies (IACS) has adopted the Common Structural Rules (CSR) for Bulk Carriers and Tankers, which specifies the requirement associated with the ultimate strength of hull girder structure. The theoretical background and the results of verification study are neither well summarized nor released. Furthermore, the requirement is not a form of deterministic formula but a form of program in which source code is not disclosed. The reliability of the non-linear structural analysis program is verified through the comparison with the results of the analysis and the model test. Then, the reliability of the ultimate strength requirement in CSR is checked by comparing with the results of rigorous non-linear analysis.

진동시험에 기초한 액상화 상세예측법 개발 (A New Assessment of Liquefaction Potential Based on the Dynamic Test)

  • 김수일;최재순;강한수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.245-252
    • /
    • 2004
  • When some enormous earthquake hazards broke out in the neighboring Japan and Taiwan, many Korean earthquake engineers thought that seismic guidelines must be adjusted safely and economically to consider the moderate earthquake characteristics. In the present aseismic guideline for liquefaction potential assessment, a simplified method using SPT-N value and a detail method based on the dynamic lab-tests were introduced. However, it is said that these methods based on the equivalent stress concept to simplify an irregular earthquake are not reliable to simulate the kaleidoscopical characteristics of earthquake loading correctly. Especially, even though various data from the dynamic lab-test can be obtained, only two data, a maximum cyclic load and a number of cycle at an initial liquefaction are used to determine the soil resistance strength in the detailed method. In this study, a new assessment of liquefaction potential is proposed and verified. In the proposed assessment, various data from dynamic lab-tests are used to determine the unique soil resistance characteristic and a site specific analysis is introduced to analyze the irregular earthquake time history itself. Also, it is found that the proposed assessment is reasonable because it is devised to reflect the changeable soil behavior under dynamic loadings resulted from the generation and development of excess pore water pressure.

  • PDF