• Title/Summary/Keyword: simple tests

Search Result 1,236, Processing Time 0.029 seconds

An Experimental Study of Piled Raft Footing on Loose Sands (느슨한 모래지반에서의 말뚝지지 전면기초에 대한 실험적 연구)

  • Kwon, Oh-Kyun;Lee, Whoal;Lee, Seung-Hyun;Oh, Se-Boong;Jang, Hak-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.439-446
    • /
    • 2003
  • In this paper the model tests have been conducted and the results are compared with those by the theoretical methods to study the behaviors of the piled raft. The size of model box is 2.2m${\times}$2m${\times}$2m. The raft is made of rigid steel plate and piles made of steel pipes. Generally the bearing capacity of group piles is designed with only the pile capacities, and the bearing capacity of raft is ignored. But the uncertainty of pile-raft-soil interaction leads to conservative design ignoring the bearing effects of raft. In the case of considering the bearing capacity of raft, the simple sum of bearing capacity of raft and that of each pile cannot be the bearing capacity of piled raft. Because the pile-raft-soil interaction affects the behavior of piled raft. Thus the effects of pile-raft-soil interaction are very important in the optimal design. In this paper, the behaviors of piled raft are studied through model tests of 2${\times}$2, 2${\times}$3, and 3${\times}$3 pile groups. The spacing between piles is changed in the model tests. And the behaviors of free standing and piled raft are also studied.

  • PDF

Detection of antibodies and antigens of Aujeszky's disease virus using dot-immunoassay (Dot-immunoassay를 이용한 Aujeszky's disease virus항원 및 항체 검출)

  • Jun, Moo-hyung;Cho, Young-sung;Chang, Kyung-soo
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.529-536
    • /
    • 1994
  • To establish more specific and simple diagnostic methods for detection of the antibodies and antigens of Aujeszky's disease virus(ADV), we designed indirect dot-immunoassay(IDI) and double sandwich dotimmunoassay(DSDI) using the solid phases of nitrocellolose paper and polystyrene plate. The diagnostic efficacy of these methods was investigated. As the sensitivity of IDI was tested by various virus concentration, the specimens with the virus titer above $10^{4.0}TCID_{50}/0.2ml$ showed positive reaction, but that below $10^{1.0}TCID_{50}/ml$ revealed negative. Tonsil emulsion at the virus titer of $10^{4.5}TCID_{50}/0.2ml$ showed the highest sensitivity as diluted by 1/100. In detection of ADV antigens from the various tissues of the rats and pigs infected with ADV, IDI using monoclonal antibody showed the higher specificity as compared with IDI using polyclonal antibody and virus isolation method. The efficacy of the DSDI for detection of ADV antibody was compared with other tests. The sensitivity of DSDI was higher than virus neutralization(VN) and agar gel immunodiffusion test(AGID). Meanwhile, specificity of DSDI was lower than AGID, but similar to IDEA. In comparison with VN test, DSDI showed 96.9% agreement to VN test that is the highest of three tests. In general, application of polyclonal antibody in both tests caused the higher sensitivity but the lower specificty.

  • PDF

Determination of Dynamic Modulus of Thin-Disk-Shaped Asphalt Concrete Specimens Using Impact Resonance Test (충격공진시험을 활용한 얇은 원판형 아스팔트 콘크리트 시편의 탄성계수 결정)

  • Kim, Dahae;Im, Jeong Hyuk;Kim, Y. Richard
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • PURPOSES : The objective of this study was to develop an impact resonance (IR) test procedure for thin disk-shaped specimens in order to determine the ${\mid}E^*{\mid}$ and phase angle values of various asphalt mixtures. METHODS : An IR test procedure was developed for evaluating thin disk-shaped specimens, in order to determine the dynamic modulus (${\mid}E^*{\mid}$) of various asphalt mixtures. The IR test method that was developed to determine the elastic modulus values of Portland cement concrete was evaluated, which method uses axisymmetric flexural vibration proposed by Leming et al. (1996). The IR tests were performed on three different mixtures of New York with varying nominal maximum aggregate sizes (NY9.5, NY19, and NY25) at six different temperatures ($10-60^{\circ}C$). The ${\mid}E^*{\mid}$ values obtained from the IR tests were compared with those determined by the commonly used AASHTO T342-11 test. RESULTS AND CONCLUSIONS : The IR test method was employed to determine the ${\mid}E^*{\mid}$ values of thin-disk-shaped specimens of various asphalt mixtures. It was found that the IR test method when used with thin disk-like specimens is a simple, practical, and cheap tool for determining the ${\mid}E^*{\mid}$ values of field cores. Further, it was found the ${\mid}E^*{\mid}$ values obtained from the IR tests using thin disk-like specimens were almost similar to those obtained using the AASHTO T342-11 test.

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • v.76 no.2
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

Structural design method of the steel brush type loading platen adopted in multi-axial compression experiments (다축압축 실험에 적용되는 철제 빗살구조 재하판의 구조 설계 기법)

  • SaGong, Myung;Lee, Jun-S.;Kim, Sung-Soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.351-359
    • /
    • 2007
  • Multi-axial compression tests have been frequently conducted to evaluate the in situ properties of rock masses and the mechanical behaviors of rock strata through the model tests. Without the proper boundary condition for the model tests, the mechanical behavior of rock mass would deviate, as can be expected, from the in situ conditions. The boundary condition will affect the internal stress distribution of the specimens and cause some distortion on the measurement. In this study, a design process regarding the steel brush, which has been employed for multi-axial compression test to reduce the frictional restraint along the specimen/loading platen interface, is introduced. The individual brushes are regarded as a simple column and beam to calculate the cross-sectional size and length of the brushes in consideration of the buckling capacity and the allowable deflection.

  • PDF

Nonlinear Dynamic Behavior of a Cold-Formed Steel Shear Panel by Shaketable Tests (진동대 실험을 통한 조립식 스틸 전단 패널의 비선형 동적 거동)

  • Kim, Tae-Wan;Lee, Moon-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.6 s.46
    • /
    • pp.31-39
    • /
    • 2005
  • The purpose of this study was to investigate the nonlinear behavior of a cold-formed steel (CFS) shear panel, which was composed of built-up columns and tension-only diagonal straps for bracing, when excited by earthquake motions. For the purpose, shaketable tests of a full-scale two-story cold-formed steel (CFS) shear panel were conducted. in the shear panel, the diagonal strap is a major lateral force resisting system, which is a very ductile member, and the columns, which are gravity resisting members, are fabricated by wooing studs, which can't develop their full flexural strength because they may buckle locally. The test results showed that the straps dissipate most of energy of the shear panel in a tension-only and pinched way and the columns dissipate it relatively smaller than the straps but they still contribute to overall dissipation. As a result of this study, investigating real nonlinear behavior of a structure in earthquakes is a very important process by shaketable tests even though it is simple.

Evaluation of Bearing Capacity of Piles in Sand Using Pile Driving Analyzer (동재하시험을 이용한 모래지반의 말뚝지지력 산정)

  • 이우진;석종수
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.145-154
    • /
    • 1997
  • Though the static pile load tests gives the mosts accurate estimation on the load carrying capacity of tested pile, it appears time-consuming and not economical. Many test methods using equipments, such as Pile Driving Analyzer(PDA), STATNAMIC, and Osterberg cell, have been introduced in Korea, and pile best using PDA has been gaining popularity because of iris fast and simple operation. Static and dynamic tests results on the piles installed in the granular coils were analyzed to investigate the effect of geometrical damping on the estimated load carrying capacity. It was found that the CAPWAP analysis without considering geometrical damping effect underestimates the pile capacity by 30~60% under certain conditions. It was observed that the underestimation of pile capacity by CAPWAP occurs on the piles installed in the water-borne granular boils by SIP methods. When Smith skin damping value(SSkn) greater than 1.0 sec/m is obtained in CAPWAP analysis, it may reflect the large possibility of underestimation of pile capacity. The introduction of the geometircal damping option in CAPWAP analysis gives reasonable pile capacity, compared with the static pile load test results, and reduces the SSb value under 0.7 sec/m.

  • PDF

A Study on the Characteristics of High Temperature and Mechanisms for Creep Deformation of AZ31 Mg Alloy (AZ31마그네슘 합금의 고온특성 및 크리이프 변형기구에 관한연구)

  • Kang, D.M.;An, J.O.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.96-101
    • /
    • 2005
  • Magnesium alloys have been widely used for many structural components of automobiles and aircraft because of high specific strength and good cast ability in spite of hexagonal closed-packed crystal structure of pure magnesium. In this study, uniaxial tension tests at high temperature and creep tests are done in order to investigate the characteristics of high temperature and mechanisms for creep deformation of AZ31 Mg alloy. Yield stress and ultimate tensile stress decreased with increasing temperature, but elongation increased from results of uniaxial tension test at high temperature. The apparent activation energy Qc, the applied stress exponent n and rupture life have been determined during creep of AZ31 Mg alloy over the temperature range of 473K to 573K and stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller, whose data are sent to computer. At around the temperature of $473K{\sim}493K$ and under the stress level of $62.43{\sim}93.59%MPa$, and again at around the temperature of $553K{\sim}573K$ and under the stress level of $23.42{\sim}39.00MPa$, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy for the creep deformation was nearly equal, respectively, and a little low to that of the self diffusion of Mg alloy including aluminum. Also rupture surfaces at high temperature have had bigger dimples than those at lower temperature by SEM.

  • PDF

The Development of Rhythmic Balance Training Equipment and its Effect on Performance for Elderly

  • Park, Da Won;Won, Cho Rong;Lee, Sung Ro;Park, Yang Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.323-331
    • /
    • 2016
  • Objective: The aims of this study were 1) to develop easy-to-use rhythmic balance training equipment for the elderly and 2) to investigate the effect of training with the equipment on balance and physical function. Method: Twenty-one elderly individuals (age: $75.4{\pm}3.34yrs$, height: $152.07{\pm}4.81cm$, weight: $58.35{\pm}8.34kg$) participated in this study. Each participant underwent balance and physical function testing before and after 12 weeks of training with the equipment. Y-balance (i.e. dynamic balance) and one leg static balance tests were used for balance testing, and timed up- and-down-stairs and five times sit-to-stand tests were used for physical function testing. A paired t test was used to determine whether there was a significant pre- and post-training difference. Results: The rhythmic balance training equipment provided a fun and motivating training program with age-friendly music, dance movements for lower extremity strength training, and touch screen controls with simple features. Post-training left foot dynamic balance was significantly greater (p<.05), and static balance with eyes open was significantly improved (p<.05) compared to pre-training. Completion of the timed up-and-down-stairs and the five times sit-to-stand tests was significantly shorter (p<.05) compared to pre-training. Conclusion: Training using the equipment developed in this study improved balance and physical function in elderly participants.