• Title/Summary/Keyword: simple tests

Search Result 1,236, Processing Time 0.027 seconds

Classification of Weathering for the Granite and Granite Gneiss in Okcheon Belt-Jecheon${\cdot}$Geumsan${\cdot}$Gimcheon in Korea (옥천대지역 -제천${\cdot}$금산${\cdot}$김천 - 에 분포하는 화강암 및 화강 편마암의 풍화분류에 관한 고찰)

  • Woo, Ik;Park, Hyuk-Jin
    • Economic and Environmental Geology
    • /
    • v.37 no.3
    • /
    • pp.355-364
    • /
    • 2004
  • A study on the weathering grade classification has been performed for granite and granite gneiss in Korea. The qualitative classification criteria of weathering were reviewed and then modified with field studies for the weathered rock masses. The thin section observations and XRD analyses for the different weathering grades rock samples showed the petrographical and petrophysical difference with respect to the weathering : the proportion of weathering-resistant minerals suck at quartz and orthoclase has a tendency to increase with the development of weathering, but that of weathering-sensible minerals such as anorthite and biotite is decreased. The ranges of physical and mechanical rock properties for different weathering grades were obtained from the laboratory rock tests and field tests for the studied rocks. And then, along with $RDI_{sq}$(Fookes et al., 1988), the weathering index $I_{a}$, (Woo, 2003) has been developed in this study to demarcate the weathering grade. Those two indices rely mainly on the water absorption ratio of rock and on the different rock strength. The range of these weathering indices have been determined with the physical and mechanical rock properties that can be obtained from simple field or laboratory tests in 4 grades $I_{a}$> 7 for F, 3.5 < $I_{a}$ < 10 for SW, 1.0 $I_{a}$< 6.0 for MW and $I_{a}$< 2.5 for HW. Consequently, the weathering index could be utilized to classify quantitatively the rock weathering grade, especially for the studied granites and the granite gneiss in Korea.

"As the Scientific Witness Is a Court Witness and Is Not a Party Witness" ("과학의 승리"는 어떻게 선언될 수 있는가? 친자 확인을 위한 혈액형 검사가 법원으로 들어갔던 과정)

  • Kim, Hyomin
    • Journal of Science and Technology Studies
    • /
    • v.19 no.1
    • /
    • pp.1-51
    • /
    • 2019
  • The understanding of law and science as fundamentally different two systems, in which fact stands against justice, rapid progress against prudent process, is far too simple to be valid. Nonetheless, such account is commonly employed to explain the tension between law and science or justice and truth. Previous STS research raises fundamental doubts upon the off-the-shelf concept of "scientific truth" that can be introduced to the court for legal judgment. Delimiting the qualification of the expert, the value of the expert knowledge, or the criteria of the scientific expertise have always included social negotiation. What are the values that are affecting the boundary-making of the thing called "modern science" that is supposedly useful in solving legal conflicts? How do the value of law and the meaning of justice change as the boundaries of modern science take shapes? What is the significance of "science" when it is emphasized, particularly in relation to the legal provisions of paternity, and how does this perception of science affect unfoldings of legal disputes? In order to explore the answers to the above questions, we follow a process in which a type of "knowledge-deficient model" of a court-that is, law lags behind science and thus, under-employs its useful functions-can be closely examined. We attend to a series of discussions and subsequent changes that occurred in the US courts between 1930s and 1970s, when blood type tests began to be used to determine parental relations. In conclusion, we argue that it was neither nature nor truth in itself that was excavated by forensic scientists and legal practitioners, who regarded blood type tests as a truth machine. Rather, it was their careful practices and crafty narratives that made the roadmaps of modern science, technology, and society on which complex tensions between modern states, families, and courts were seen to be "resolved".

Clinical Presentation of the Patients with Non-traumatic Chest Pain in Emergency Department (응급의료센터에 내원한 비외상성 흉통환자의 임상 양상)

  • Chung, Jun-Young;Lee, Sam-Beom;Do, Byung-Soo;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.283-295
    • /
    • 1999
  • Background: Patients with acute non-traumatic chest pain are among the most challenging patients for care by emergency physicians, so the correct diagnosis and triage of patients with chest pain in the emergency department(ED) becomes important. To avoid discharging patients with acute myocardial infarction(AMI) without medical care, most emergency physicians attempt to admit almost all patients with acute chest pain and order many laboratory tests for the patients. But in practice, many patients with non-cardiac pain can be discharged with simple tests and treatment. These patients occupy expensive intensive care beds, substantially increasing financial cost and time of stay at ED for the diagnosis and treatment of myocardial ischemia and AMI. Despite vigorous efforts to identify patients with ischemic heart disease, approximately 2% to 5% of patients presented to the ED with AMI and chest pain are inadvertently discharged. If the cause for the chest pain is known, rapid and accurate diagnosis can be implemented, preventing wastes in time and money and inadvertent discharge. Methods and Results: The medical records of 488 patients from Jan. 1 to Dec. 31, 1997 were reviewed. There were 320(angina pectoris 140, AMI 128) cases of cardiac diseases, and 168(atypical chest pain 56, pneumothorax 47) cases of non-cardiac diseases. The number of associated symptoms were $1.1{\pm}0.9$ in non-cardiac diseases, $1.4{\pm}1.1$ in cardiac diseases and $1.7{\pm}1.1$ in AMI(p<0.05). In laboratory finding the sensitivity of electrocardiography(EKG) was 96.1%, while the sensitivity of myoglobin test ranked 45.1%. Admission rate was 71.6% in for cardiac diseases and 50.6% for non-cardiac diseases(p<0.01). Mortality rate was 8.8% in all cases, 13.8% in cardiac diseases, 0.6% in non-cardiac diseases, and 28.1% especially in AMI. Conclusion: In conclusion, all emergency physicians should have thorough knowledge of the clinical characteristics of the diseases which cause non-traumatic chest pain, because a patient with any of these life-threatening diseases would require immediate treatment. Detailed history on the patient should be taken and physical examination performed. Then, the most simple diagnostic approach should be used to make an early diagnosis and to provide treatment.

  • PDF

The Influence of the Direction of Applied Load(Compression and Uplift) and the Diameter of the Pile on the Pile Bearing Capacity (하중 작용 방향(압축과 인발)과 말뚝의 직경이 말뚝 지지력에 미치는 영향)

  • 이명환;윤성진
    • Geotechnical Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-64
    • /
    • 1991
  • The reliable estimation of pile bearing capacity is essential for the improvement of the re- liability and the cost-effectiveness of the design. There have been numerous pile bearing capacity prediction methods proposed up to now, however, execpt for the estimation made from the result of the pile loading test, not one method is appropriate for the reliable prediction. Due to the considerable time and expenses required to carry out the pile loading test, the test has seldom been utilized. The development of Simple Pile Loading Test(SPLT) which utilizes the pile skin friction as the required reaction force to cause the pile tip settlement, provides a solution to perform more pile loading tests and consequently a more economical pile design is possible. The separate measurement of skin friction and tip resistance during the course of performing SPLT provides a better understanding of the pile behavior than the result of the conventional pile loading test where only the total resistance is measured. On the other hand, there are some points to be clarified in order to apply the test results of SPLT to practical problem. They are the direction of the applied load to mobilize the skin friction and the use of reduced sized sliding core. In this research, both the SPLT and the conventional pile loading test on 406mm diameter steel pipe pile have been performed. From the result, it would be safe to use the measured SPLT skin friction value directly in the design, since the value is somewhat lower than the value measured in the conventional test. It is further assumed that the tip resistance value of the reduced sized sliding core should properly be analysed by taking the incluonce of scale effect into consideration.

  • PDF

A Study on the Creep Deformation Characteristic of AZ31 Mg Alloy at High Temperature (AZ3l 마그네슘 합금의 고온 크리이프 변형특성에 관한 연구)

  • An Jungo;Kang Daemi;Koo Yang;Sim Sungbo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.186-192
    • /
    • 2005
  • The apparent activation energy Qc, the applied stress exponent n, and rupture life have been determined from creep test results of AZ31 Mg alloy over the temperature range of 200$^{\circ}C$ to 300$^{\circ}C$ and the stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller with data acquisition computer. At the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy fur the creep deformation was nearly equal to that of the self diffusion of Mg alloy including aluminum From the above results, at the temperature of $200^{\circ}C{\sim}220^{\circ}C$ the creep deformation for AZ31 Mg alloy seemed to be controlled by dislocation climb but controlled by dislocation glide at $280^{\circ}C{\sim}300^{\circ}C$ .And relationship beween rupture time and stress at around the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and again at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, respectively, appeard as fullow; log$\sigma$=-0.18(T+460)(logtr+21)+5.92, log$\sigma$ = -0.25(T+460)(logtr+21)+8.02 Also relationship beween rupture time and steady state creep rate appears as follow; ln$\dot$ =-0.881ntr-2.45

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.

Estimate of the Bearing Capacity on Subbase and Subgrade with Dynamic Plate Bearing Test (동평판재하시험을 이용한 도로하부 재료의 지지력 평가)

  • Youn, Ilro;Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.53-60
    • /
    • 2013
  • The compaction control method of national road substructure is using field density test to determine the relative compaction and plate bearing test to check the load bearing capacity. However, these two tests digitize a construction site manager's judgment based on his experience, so mechanical basis is weak. Resilient modulus method, which is recently being used to resolve such problem, is evaluated as a rational design method of pavement structure that can rationally reflect the stress-strain state of pavement materials that is caused by the condition of load repetition of vehicle load. However, the method of measuring the resilient modulus is difficult and lengthy, and it has many problems. To replace it, light falling weight test is recently being proposed as a simple test method. Therefore, this research uses dynamic plate loading test, which quickly and simply measures the elastic modulus of the subgrade and sub-base construction and site of maintenance, to judge the possibility of compaction control of the stratum under the road, and it proposes relation formula by analyzing the result of static load test.

Method comparison for analyzing formaldehyde in marker pen ink (마킹펜 잉크 내 폼알데하이드 분석법 비교)

  • Park, Kwang Seo;Kim, Yong Shin;Choe, Eun Kyung
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.115-124
    • /
    • 2020
  • Marker pens belong to school things that are controlled by the regulation system called safety confirmation under special act on the safety of products for children with the formaldehyde criteria of 20 mg/kg. With nine marker pens available commercially, formaldehyde in marker pen ink was analyzed by present test standard where marking on a fabric swatch with a pen and extracting the swatch in water and derivatization with Nash reagent followed by UV/Vis spectrophotometeric measurement (Nash-UV/Vis method), giving not detected results or a false positive result in case of a colored water extract. However, the contents of formaldehyde in ink of nine marker pens were determinded to range between 3.2 ~ 93.2 mg/kg with three results above the safety criteria of 20 mg/kg by HPLC/DAD measurements on DNPH derivatives of formaldehyde (DNPH-HPLC/DAD method) in ink dissolved directly in water using an ultrasonic bath. Therefore, the DNPH-HPLC/DAD method with the extraction of ultrasonic dissolving ink in water is proposed as a proper method for analyzing formaldehyde in ink. The proposed method has advantages of lower detection limit and accuracy with colored extracts as well as a simple and fast extraction. The accuracy and precision of this method was estimated to be 90.1 ~ 105.4 % and 0.6 ~ 3.3 %, respectively by spiking tests in the ranges of 20 mg/kg and 40 mg/kg using matrixes such as highlighter pen ink, board marker ink, chalk marker pen ink and painter marker ink.

Comparison of Smart Phone Application Based Hearing Screening and Hearing Handicap Inventory (스마트 폰 애플리케이션 기반 청각선별과 설문 청각선별의 비교)

  • Heo, Seung-Deok;Park, Chan-Ho;Song, Byung-Seop
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.73-79
    • /
    • 2017
  • It is difficult to detect the adult hearing loss after the language acquisition because of its slow progression, which can be evaluated voluntarily and actively when the appropriate tools are provided. Smartphones are one of useful tools, and they can utilize surveys and/or applications for hearing screening. This study aims to verify the possibility as a tool discovering delayed acquired hearing losses by comparing the pure tone screening application (app_PTS) which was recently developed by our research team and hearing handciap inventory (HHI). The subjects were 22 people whose age ranges from 10s to 80s. For pure tone averages (PTAs), hearing threshold level was selected the best one in same frequency, in both ears. Sensitivity and specificity of HHI were confirmed based on self awareness of hearing loss and PTAs at 1, 2, 4 kHz. Comparisons of two tests were measured by analyzing simple regression of correlation between PTAs of App_PTS and HHI scores. Sensitivity and specificity were 1.000 in both criteria. There was a statistically significant relationship between the PTAs_4 kHz and HHI (R-square = .951, p = .000). Hearing screening by questionnaire showed high correlation with smart phones based on application. Therefore, it can be useful as a hearing screening tool for individual life cycle using an user-friendly tool.