• Title/Summary/Keyword: similar materials

Search Result 4,776, Processing Time 0.039 seconds

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Surface and Chemical Properties of Surface-Modified UHMWPE Powder and Mechanical and Thermal Properties of Its Impregnated PMMA Bone Cement V. Effect of Silane Coupling Agent on the Surface Modification of UHMWPE Powder

  • Yang Dae Hyeok;Yoon Goan Hee;Shin Gyun Jeong;Kim Soon Hee;Rhee John M.;Khang Gilson;Lee Hai Bang
    • Macromolecular Research
    • /
    • v.13 no.2
    • /
    • pp.120-127
    • /
    • 2005
  • Conventional poly(methyl methacrylate) (PMMA) bone cement has been widely used as an useful biopolymeric material to fix bone using artificial prostheses. However, many patients had to be reoperated, due to the poor mechanical and thermal properties of conventional PMMA bone cement, which are derived from the presence of unreacted MMA liquid, the shrinkage and bubble formation that occur during the curing process of the bone cement, and the high curing temperature ($above 100^{\circ}C$) which has to be used. In the present study, a composite PMMA bone cement was prepared by impregnating conventional PMMA bone cement with ultra high molecular weight polyethylene (UHMWPE) powder, in order to improve its mechanical and thermal properties. The UHMWPE powder has poor adhesion with other biopolymeric materials due to the inertness of the powder surface. Therefore, the surface of the UHMWPE powder was modified with two kinds of silane coupling agent containing amino groups (3-amino propyltriethoxysilane ($TSL 8331^{R}$) and N-(2-aminoethyl)-3-(amino propyltrimethoxysilane) ($TSL 8340^{R}$)), in order to improve its bonding strength with the conventional PMMA bone cement. The tensile strengths of the composite PMMA bone cements containing $3 wt\%$ of the UHMWPE powder surface-modified with various ratios of $TSL 8331^{R}$ and $TSL 8340^{R}$ were similar or a little higher than that of the conventional PMMA bone cement. However, no significant difference in the tensile strengths between the conventional PMMA bone cement and the composite PMMA bone cements could be found. However, the curing temperatures of the composite PMMA bone cements were significantly decreased.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.

Physicochemical characterization of porcine bone-derived grafting material and comparison with bovine xenografts for dental applications

  • Lee, Jung Heon;Yi, Gyu Sung;Lee, Jin Woong;Kim, Deug Joong
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.6
    • /
    • pp.388-401
    • /
    • 2017
  • Purpose: The physicochemical properties of a xenograft are very important because they strongly influence the bone regeneration capabilities of the graft material. Even though porcine xenografts have many advantages, only a few porcine xenografts are commercially available, and most of their physicochemical characteristics have yet to be reported. Thus, in this work we aimed to investigate the physicochemical characteristics of a porcine bone grafting material and compare them with those of 2 commercially available bovine xenografts to assess the potential of xenogenic porcine bone graft materials for dental applications. Methods: We used various characterization techniques, such as scanning electron microscopy, the Brunauer-Emmett-Teller adsorption method, atomic force microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and others, to compare the physicochemical properties of xenografts of different origins. Results: The porcine bone grafting material had relatively high porosity (78.4%) and a large average specific surface area (SSA; $69.9m^2/g$), with high surface roughness (10-point average roughness, $4.47{\mu}m$) and sub-100-nm hydroxyapatite crystals on the surface. Moreover, this material presented a significant fraction of sub-100-nm pores, with negligible amounts of residual organic substances. Apart from some minor differences, the overall characteristics of the porcine bone grafting material were very similar to those of one of the bovine bone grafting material. However, many of these morphostructural properties were significantly different from the other bovine bone grafting material, which exhibited relatively smooth surface morphology with a porosity of 62.0% and an average SSA of $0.5m^2/g$. Conclusions: Considering that both bovine bone grafting materials have been successfully used in oral surgery applications in the last few decades, this work shows that the porcinederived grafting material possesses most of the key physiochemical characteristics required for its application as a highly efficient xenograft material for bone replacement.

Fabrication and Characterization of Ag-coated BCP Scaffold Derived from Sponge Replica Process (스폰지 복제법을 이용한 Ag 코팅 BCP 지지체의 제조 및 평가)

  • Kim, Min-Sung;Kim, Young-Hee;Song, Ho-Yeon;Min, Young-Ki;Lee, Byong-Taek
    • Korean Journal of Materials Research
    • /
    • v.20 no.8
    • /
    • pp.418-422
    • /
    • 2010
  • As a starting material, BCP (biphasic calcium phosphate) nano powder was synthesized by a hydrothermal microwave-assisted process. A highly porous BCP scaffold was fabricated by the sponge replica method using 60 ppi (pore per inch) of polyurethane sponge. The BCP scaffold had interconnected pores ranging from $100\;{\mu}m$ to $1000\;{\mu}m$, which were similar to natural cancellous bone. To realize the antibacterial property, a microwave-assisted nano Ag spot coating process was used. The morphology and distribution of nano Ag particles were different depending on the coating conditions, such as concentration of the $AgNO_3$ solution, microwave irradiation times, etc. With an increased microwave irradiation time, the amount of coated nano Ag particles increased. The surface of the BCP scaffold was totally covered with nano Ag particles homogeneously at 20 seconds of microwave irradiation time when 0.6 g of $AgNO_3$ was used. With an increased amount of $AgNO_3$ and irradiation time, the size of the coated particles increased. Antibacterial activities of the solution extracted from the Ag-coated BCP scaffold were examined against gram-negative (Escherichia coli) and gram-positive bacteria (Staphylococcus aureus). When 0.6 g of $AgNO_3$ was used for coating the Ag-coated scaffold, it showed higher antibacterial activities than that of the Ag-coated scaffold using 0.8 g of $AgNO_3$.

Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

  • Lee, Gyeong-Geun;Kim, Min-Chul;Yoon, Ji-Hyun;Lee, Bong-Sang;Lim, Sangyeob;Kwon, Junhyun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.760-768
    • /
    • 2017
  • The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant's lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

Effect of Operating Condition Change on the Conversion Efficiency of TWC with HCNG Engine (운전조건 변화가 HCNG 엔진용 삼원촉매 전환효율에 미치는 영향)

  • Kim, Chang-Gi;Lee, Sung-Won;Yi, Ui-Hyung;Park, Cheol-Woong;Lee, Sun-Youp;Choi, Young;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.40-46
    • /
    • 2015
  • Stoichiometric combustion engine with Three-way catalyst had an advantage that can reduce the harmful emissions effectively. Fuel equivalence ratio controlled from engine is very important because Fuel equivalence ratio with high conversion efficiency was narrow. This study analyzed the conversion efficiency under whole range of operating area for to evaluate the performance of three-way catalyst. In order to identify the Optimum conversion efficiency, the conversion efficiency due to change the control value of fuel equivalence ratio was investigated. The result show that conversion efficiency of emissions(more than 95%) has discovered by means of fuel equivalence ratio control at each test condition. As engine power increases, optimal fuel equivalence ratio tended to increase linearly under operating conditions of similar exhaust gas temperature.

Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti (입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동)

  • Lee Seung-Woo;Kim Yun-Jong;Ruy Jae-Gyeoung;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

Effect of Anatase TiO2 Doping Power on Electrical, Optical and Structural Properties of Multicomponent TiO2-Doped ITO Electrodes (아나타세 TiO2 도핑파워가 다성분계 TiO2-ITO 투명 전극의 전기적, 광학적, 구조적 특성에 미치는 효과)

  • Lim, Jong-Wook;Choi, Yoon-Young;Cho, Chung-Ki;Choi, Kwang-Hyuk;Kim, Han-Ki
    • Korean Journal of Materials Research
    • /
    • v.21 no.7
    • /
    • pp.371-376
    • /
    • 2011
  • We report on the effects of $TiO_2$ doping power on the characteristics of multicomponent $TiO_2$-ITO (TITO) electrodes prepared by a multi-target sputtering system with tilted cathode guns. Both as-deposited and annealed TITO electrodes showed linearly increased sheet resistance and resistivity with increasing $TiO_2$ doping power. However, the TITO electrodes exhibited a fairly high optical transmittance regardless of the $TiO_2$ doping power due to the high transparency of the $TiO_2$. Although the annealed TITO showed much lower sheet resistance and resistivity relative to the as-deposited samples, the electrical properties of the annealed samples exhibited similar dependence on the $TiO_2$ power to the as-deposited samples. In addition, it was found that doping of an anatase $TiO_2$ in the ITO electrode prevented the preferred (222) orientation of the TITO electrodes. Although the TITO electrode showed higher sheet resistance and resistivity than that of the pure ITO electrode, it offers a very smooth surface and usage of a low-cost Ti element. It is thus considered a promising multicomponent transparent conducting electrode for cost-efficient flat panel displays and photovoltatics.

Tensile and Charpy Impact Properties of High-Strength Bainitic Steels Fabricated by Controlled Rolling Process (제어압연한 베이나이트계 고강도강의 인장 및 충격 성질)

  • Sung, Hyo Kyung;Shin, Sang Yong;Hwang, Byoungchul;Lee, Chang Gil;Kim, Nack J.;Lee, Sunghak
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.7
    • /
    • pp.615-624
    • /
    • 2010
  • This study is concerned with tensile and Charpy impact properties of high-strength bainitic steels fabricated by controlled rolling process. Six kinds of steels were fabricated by varying finish rolling temperature, start cooling temperature, and cooling rate, and their microstructures and tensile and Charpy impact properties were investigated. Their effective grain sizes were also characterized by the electron backscatter diffraction analysis. The microstructures of the steels rolled in the single phase region were most similar to those of the steels rolled in the two phase region. The steels cooled from $700{^{\circ}C}$ were composed mainly of granular bainites, while those cooled from $600{^{\circ}C}$ contained a number of bainitic ferrites, which resulted in the decrease in ductility and upper shelf energy in spite of the increase in strength. In the steels cooling from $600^{\circ}C$, fine acicular ferrites were well formed when the cooling rate was slow, which led to the best combination of high ductility, high upper shelf energy, and low energy transition temperature according to the decrease in the overall effective grain size due to the presence of acicular ferrites having smaller effective grain size.